Letter Sequence Approval |
|---|
CAC:001028, ECCS Response Time Testing (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML17318A087, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI 2018-01-10
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Paula Gerfen Senior Vice President, Generation, and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant Mail Code 104/6/608 P.O. Box 56 Avila Beach, CA 93424
SUBJECT:
SAFETY EVALUATION REPORT FOR THE PACIFIC GAS AND ELECTRIC COMPANY HUMBOLDT BAY INDEPENDENT SPENT FUEL STORAGE INSTALLATION QUALITY ASSURANCE PLAN HBI-L6 REVISION 1 (CAC NO.
001028)
Dear Paula Gerfen:
By letter dated July 19, 2022, Pacific Gas and Electric Company (PG&E) submitted Revision 1 to HBI-L6, Humboldt Bay Independent Spent Fuel Storage Installation Quality Assurance Plan, for U.S. Nuclear Regulatory Commission (NRC) review and approval under Title 10 of the Code of Federal Regulations (10 CFR) Part 72. (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22200A242), supplemented by responses to NRC requests for additional information dated on February 16, 2023 (ML23047A366), and June 6, 2023 (ML23157A305).
As a result of our review of the proposed Revision 1 of the Humboldt Bay Independent Spent Fuel Storage Installation (ISFSI) quality assurance plan (QAP), NRC staff prepared a safety evaluation report (SER) to document the independent verification against the requirements of Title 10 of the Code of Federal Regulation (10 CFR) Part 72. The SER in Enclosure 1 contains information regarding the scope of the staffs review and our conclusions for the Humboldt Bay ISFSI QAP, HBI-L6, Revision 1. The staff found that the Humboldt Bay Part 72 ISFSI QAP meets the requirements of 10 CFR Part 72, subpart G, Quality Assurance.
May 23, 2024
P. Gerfen 2
If you have any questions regarding this approval of the QAP, please contact me at (301) 415-6004 or Raju Patel at (301) 415-3511.
Sincerely, Hector Rodriguez-Luccioni, Chief Inspection and Oversight Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-27 CAC No. 001028
Enclosure:
Safety Evaluation Report Signed by Rodriguez-Luccioni, Hector on 05/23/24
ML24121A280 OFFICE DFM/IOB E
DFM E
DFM/IOB E
NAME RPatel WWheatley HRodriguez DATE 5/2/2024 5/3/2024 5/23/2024
Enclosure UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION REPORT Docket No. 07200027 Humboldt Bay Independent Spent Fuel Storage Installation Quality Assurance Plan Introduction By letter dated July 19, 2022, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22200A242), as supplemented on February 16, 2023 (ML23047A366), and June 6, 2023 (ML23157A305), in responses to U.S. Nuclear Regulatory Commission (NRC) requests for additional information (ADAMS Accession No. ML22340A537),
Pacific Gas and Electric Company (PG&E) (the licensee) submitted Revision 1 to HBI-L6, Humboldt Bay Independent Spent Fuel Storage Installation (ISFSI) Quality Assurance Plan (QAP), to the NRC for review and approval.
The NRC staff (the staff) reviewed the application, including relevant supplemental information in response to the NRC request for additional information (RAI), using the guidance in NUREG-1567, Standard Review Plan for Spent Fuel Dry Storage Facilities, Section 12, Quality Assurance Evaluation, dated March 2000 (ML003686776). Based on the statements and representations in the QAP Description, as supplemented, the staff concluded that the package meets the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 72, Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater than Class C Waste, subpart G, Quality Assurance.
The following sections include the staffs evaluation in the areas related to the review.
REGULATORY BASIS The NRCs regulation 10 CFR 72.24(n) has requirements for each application for a license under Part 72 to include a description of the QA program that satisfies the requirements of subpart G. In addition, 10 CFR 72.56 requires, in part, whenever a holder of a specific license desires to amend the license (including a change to the license conditions), an application for an amendment shall be filed with the Commission fully describing the changes desired and the reasons for such changes.
Section 72.140, Quality Assurance Requirements, of subpart G, establishes the QA requirements for the design, purchase, fabrication, handling, shipping, storing, cleaning assembly, inspection, testing, operation, maintenance, repair, modification of structures, systems, and components, and decommissioning that are important to safety. Section 72.144, Quality Assurance Program, of subpart G, establishes requirements for indoctrination, and training of personnel. Section 72.144 states, in part, that, The licensee, applicant for licensee, certificate holder, and applicant for a Certificate of Compliance shall provide for indoctrination and training of personnel performing activities affecting quality as necessary to assure that suitable proficiency is achieved and maintained.
2 The regulation in 10 CFR 72.24(h) and (n) requires the safety analysis report for a proposed ISFSI or Monitored Retrievable Storage Installation for the receipt, handling, packaging, and storage of spent fuel, high-level radioactive waste, and/or reactor-related greater than Class C waste, to include information on the planned managerial and administrative controls that would ensure safe operation of the ISFSI or Monitored Retrievable Storage facility. The information on the controls shall also include a discussion on how the applicable requirements of subpart G will be satisfied.
TECHNICAL EVALUATION The purpose of this evaluation is to review and evaluate the proposed changes made in Revision 1 to HBI-L6, Humboldt Bay ISFSI Quality Assurance Plan to assess whether the HB ISFSI QAP as written continues to comply with the requirements of 10 CFR Part 72, subpart G.
The staff reviewed the application, including relevant supplemental information, using the guidance in NUREG-2215, Standard Review Plan for Spent Fuel Dry Storage Systems, and Facilities, Chapter 15, Quality Assurance Evaluation, dated April 2020 (ML20121A190).
The proposed changes made under Revision 1 to HBI-L6, Humboldt Bay Independent Spent Fuel Installation Quality Assurance Plan, are as follows:
1.
Section 1.3, Organization Responsibilities, was revised to change the title Senior Vice President, Generation and Chief Nuclear Officer to Chief Nuclear Officer (CNO), without any changes to the responsibilities, authorities, and duties of the CNO performing activities affecting quality.
2.
Section 2.6.2, Staff Qualifications, revise the Radiation Protection Manager (RPM) qualification (experience and training) requirements from Regulatory Guide (RG) 1.8, Revision 2, to RG 1.8, Revision 4. The licensee provided detail justification on the changes to the RPM qualification and training requirements indicating that these changes are not impacted by the transition from RG 1.8 Revision 2 to Revision 4. The licensee in their justification stated that HB ISFSI being not an operating power plant, onsite radiation protection (RP) is limited and mostly performed by Diablo Canyon Power Plant (DCPP) radiation staff quarterly, annually, and once 5 years for cask inspections. The licensee stated that the focus of RP experience is related to As Low As Reasonably Achievable, radiation material storage, handling, and shipping, environmental monitoring, and related NRC regulations, and licensing. The licensee further stated that the periodic onsite RP support is considered sufficient to ensure the RPM is knowledgeable of characteristics and challenges to implement the limited RP activities described in HB ISFSI QAP and RP program during long-term storage. In addition, the licensee stated that, the staff at the HB ISFSI performing activities affecting quality is provided with general site awareness training (e.g., emergency plan, security, site operations), therefore, the transition from Revision 2 to Revision 4 of the RG 1.8, has no impact on the RPM general training requirements at the HB ISFSI.
3.
Relocated the RPM qualification and training guidance from the HB ISFSI QAP to the Final Safety Analysis Report (FSAR), Chapter 9.
4.
Section 12.1, Control of Measuring and Test Equipment, was revised in response to staffs RAI, to include measures to ensure that measuring, and test equipment shall be controlled,
3 calibrated, and periodically adjusted by DCPP organizations in accordance with an NRC approved quality assurance program.
EVALUATION FINDINGS The staff reviewed and evaluated licensees proposed changes to the QAP and concluded that it satisfied the requirements of 10 CFR Part 72, subpart G. The staff assessed that:
1.
The licensee maintained the responsibilities, authorities, and duties of the CNO performing activities affecting quality.
2.
The licensee provided reasonable justification that support the change to the RPM qualification and training requirements such that the changes are not impacted by the transition from RG 1.8 Revision 2 to Revision 4.
3.
The licensee relocation of the RPM qualification and training guidance from the QAP to SAR Chapter 9, to be administrative.
4.
The licensee established measures to ensure measuring and test equipment are controlled, calibrated, and adjusted by qualified personnel using qualified procedures, will comply with the requirements of 10 CFR Part 72, subpart G; 5.
The QA program satisfied the requirements of 10 CFR 72.24(n).
REFERENCES 1.
PG&E Letter HIL-23-006, Revised Response to NRC Request for Additional Information on Revision 1 to the Humboldt Bay ISFSI Quality Assurance Plan, dated June 6, 2023, (ML23157A305).
2.
PG&E Letter, HIL-23-001, Response to NRC Request for Additional Information on Revision 1 to the Humboldt Bay ISFSI Quality Assurance Plan, dated February 16, 2023 (ML23047A366).
3.
NRC Letter, Humboldt Bay Independent Spent Fuel Storage Installation Revision 1 to Humboldt Bay ISFSI Quality Assurance Plan, dated December 16, 2022 (ML22340A535).
4.
PG&E Letter HIL-22-004, Revision 1 to Humboldt Bay ISFSI Quality Assurance Plan, dated July 19, 2022 (ML22200A242).
5.
NUREG-2215 Standard Review Plan for Spent Fuel Dry Storage Systems and Facilities, Chapter 15, Quality Assurance Evaluation, dated April 2020 (ML20121A190).
CONCLUSION Based on the evaluation of the proposed changes to the QAP, the staff concluded that the Humboldt Bay ISFSI QAP, HBI-L6, Revision 1, dated June 6, 2023, is acceptable and in conformance with the applicable requirements of 10 CFR Part 72, subpart G.