Letter Sequence Approval |
---|
|
|
MONTHYEARML18215A2022018-07-10010 July 2018, 31 July 2018 ISFSI - Transmittal of License Renewal Application Project stage: Request ML18215A2132018-07-31031 July 2018 Humboldt Bay ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018 Project stage: Other ML18222A3512018-08-10010 August 2018 E-Mail from C. Markley/Nrc to P. Soenen/Pge Acknowledgement of NRC Receipt of Humboldt Bay ISFSI Renewal Application Project stage: Other ML18267A1932018-09-20020 September 2018 Letter to J. Welsch Request for Supplemental Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2514 (CAC No. 001028) Project stage: Approval ML18267A1912018-09-20020 September 2018 Package: Request for Supplemental Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2514 (CAC No. 001028) Project stage: Request ML18267A1922018-09-20020 September 2018 Enclosurequest for Supplemental Information: (Letter to J. Welsch Request for Supplemental Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2 Project stage: Approval ML18317A2712018-11-0808 November 2018 E-Mail from C. Markley/Dsfm to P. Soenen/Pg&E Acknowledgement of NRC Acceptance of Humboldt Bay ISFSI Renewal Application for Review Project stage: Acceptance Review ML18319A1472018-11-14014 November 2018 Letter to J. Welsch Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2514 - Accepted for Review Project stage: Other ML19115A2832019-04-29029 April 2019 Package: Humboldt Bay Renewal RAI Call Project stage: Request ML19122A2312019-04-30030 April 2019 Letter to J. Welsch Request for Additional Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2514 (CAC No. 001028) Project stage: RAI ML19122A2292019-04-30030 April 2019 Package: Letter to J. Welsch Request for Additional Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2514 (CAC No. 001028) Project stage: Request ML19122A2302019-04-30030 April 2019 Enclosurai (Letter to J. Welsch Request for Additional Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2514 (CAC No. 001028)) Project stage: RAI ML19266A4432019-09-10010 September 2019 Letter to J. M. Welsch U.S. Nuclear Regulatory Commission Approval of Holtec International Request for Withholding Information from Public Disclosure for Humboldt Bay ISFSI Renewal Partial Request for RAI Responses Project stage: RAI L-19-013, Independent Spent Fuel Storage Installation, Revision to the Renewal Application (Cac/Epid No. 001028/L-2018-RNW-0016)2019-11-21021 November 2019 Independent Spent Fuel Storage Installation, Revision to the Renewal Application (Cac/Epid No. 001028/L-2018-RNW-0016) Project stage: Other ML19337C6332019-11-21021 November 2019 Independent Spent Fuel Storage Installation, Revision to the Renewal Application (Cac/Epid No. 001028/L-2018-RNW-0016) Project stage: Request ML20161A0252020-06-10010 June 2020 Letter to J. Welsch Re. Issuance of Renewed License No. SNM-2514 Project stage: Approval 2018-09-20
[Table View] |
|
---|
Category:Request for Additional Information (RAI)
MONTHYEARML22340A5372022-12-19019 December 2022 Encl - Humboldt Bay RAI, HBI-L6, Humboldt Bay ISFSI Quality Assurance Plan, Rev. 1 ML22340A5362022-12-19019 December 2022 Independent Spent Fuel Storage Installation (ISFSI) Revision 1 to Humbold Bay ISFSI Quality Assurance Plan ML21091A0472021-04-0101 April 2021 Request for Additional Information on License Amendment Request to Revise the License Termination Plan ML20261H5512020-08-12012 August 2020 E-Mail Dated August 12, 2020, from John Hickman, NRC, to William Barley, Pg&E, Forwarding a Request for Additional Information on the Humboldt Bay Caisson Final Status Survey Report ML19122A2302019-04-30030 April 2019 Enclosurai (Letter to J. Welsch Request for Additional Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2514 (CAC No. 001028)) ML18267A1922018-09-20020 September 2018 Enclosurequest for Supplemental Information: (Letter to J. Welsch Request for Supplemental Information for the Technical Review of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License No. SNM-2 ML13357A7672013-12-24024 December 2013 E. Halpin Ltr. Request for Additional Information Regarding Amendment Request to Add License Condition 2.C.5 ML13347B3092013-12-16016 December 2013 E. Halpin Ltr. Request for Additional Information for the Decommissioning Funding Status for Humboldt Bay ML1126304822011-09-22022 September 2011 Letter to John T. Conway Humboldt Bay Decommissioning Funding Request for Additional Information ML0829500802008-10-20020 October 2008 E-mail, Humbolt and Diablo Canyon Rais for Use of Weighting Factors for Ede ML0511805012005-05-10010 May 2005 Request for Additional Information for License Transfer Applications ML0434403502004-12-0909 December 2004 Request for Additional Information Regarding Spent Fuel Pool Davit Crane Design Application (TAC No. L52634) 2022-12-19
[Table view] |
Text
REQUEST FOR SUPPLEMENTAL INFORMATION Pacific Gas & Electric Company License Renewal Application Docket No. 72-27 License No. SNM-2514 This request for supplemental information (RSI) identifies information needed by the U.S.
Nuclear Regulatory Commission (NRC) staff in connection with its review of the renewal application. NUREG-1927, Revision 1, Standard Review Plan for Renewal of Specific Licenses and Certificates of Compliance for Dry Storage of Spent Nuclear Fuel was used by the staff in its review of the application. Each RSI describes information needed by the staff for it to begin its technical review of the application to determine whether the applicant has demonstrated compliance with the regulatory requirements.
In responding to the following RSIs, the staff notes that activities a licensee is performing during the current licensing period may be credited towards aging management in the renewed period, provided that the applicant demonstrates that the activities can effectively manage the effects of aging.
Humboldt Bay (HB) ISFSI Renewal RSI HB1: Provide a justification (e.g., analysis, test, inspection, etc.) for treating the external environment of the HI-STAR Humboldt Bay (HB) greater than Class C (GTCC) Waste Container (GWC) as embedded (i.e., with no potential ingress of moisture or contaminants).
The application states that the external HI-STAR HB GWC subcomponents are exposed to the internal HI-STAR GTCC overpack environment (i.e., enclosed air environment), which is ambient air. The application also states that no overpack drying was implemented during the closure of the bolted overpack, thus, the enclosed air environment, while isolated during the long-term storage period, is considered saline air (Table 3.1-2). The application also states the bolted overpack does not allow for the opportunity to introduce additional water or oxygen to the environment after initial overpack bolting and is thus similar to an embedded environment.
Table 3.7-1 of the application includes localized corrosion (crevice corrosion and pitting corrosion) as a possible aging mechanism in the Aging Management Review of GWC. The applicant excluded the potential for localized corrosion and chloride-induced stress corrosion cracking (CISCC) because the GWC was assumed to be maintained in an embedded environment, consistent with guidance provided in NUREG-2214. However, there is no justification to support the assumption that the enclosed air environment performs similar to an embedded environment in the bolted overpack without seals.
The staff requests that the applicant provide a justification (e.g., analysis, test, inspection, etc.) for treating the external environment of the GWC as embedded, such that localized corrosion and CISCC can be excluded during the renewal period.
This information is needed for evaluating the HI-STAR Humboldt Bay (HB) ISFSI Renewal, in compliance with 10 CFR 72.42 (a)(1).
Enclosure
RSI HB2: Provide an aging management review and aging management activities for the cask transportation system and lid retention device or, alternatively, provide justification that these components will not be used after they reach 20 years of service.
Table 2-1 of the license renewal application (LRA) states that the important-to-safety cask transportation system and lid retention device are not in scope of renewal. The LRA supports this position for the transportation system by citing the shared use of the system with Diablo Canyon, the potential re-certification of the system after it reaches 20 years of service, and current maintenance requirements. For the lid retention device, the table states that this component does not support a long-term storage function.
The guidance in NUREG-1927, Section 2.4.2 states that all important-to-safety components should be included within the scope of the renewal. The shared use of the transportation system and its maintenance or re-certification activities do not preclude the need to provide an aging management program to manage the effects of aging. However, the staff notes that maintenance or re-certification activities may be credited in an aging management program, provided that these activities are demonstrated to adequately manage any aging effects identified in an aging management review.
Regarding the lid retention device, the staff notes that the use of this component is described in the safety analysis report, Section 4.4.1.2.5, Unloading Operations, and Section 5.1.1.4, Off-Normal Event Recovery Operations. Thus, it appears that this component supports a long-term function.
This information is required to determine compliance with 10 CFR 72.42(a).
2