Letter Sequence Approval |
|---|
CAC:001028, ECCS Response Time Testing (Approved, Closed) EPID:L-2018-NEW-0001, International, Issuance of Materials License SNM-2516 for the HI-STORE Consolidated Interim Storage Facility ISFSI (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML17318A087, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI 2018-01-10
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 26, 2019 Ms. Kim Manzione, Licensing Manager Holtec International Holtec Technology Campus One Holtec Boulevard Camden, NJ 08104
SUBJECT:
HOLTEC INTERNATIONALS APPLICATION FOR SPECIFIC INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE FOR THE HI-STORE CONSOLIDATED INTERIM STORAGE FACILITY FOR SPENT NUCLEAR FUEL - REQUEST FOR CLARIFICATION OF RESPONSES RELATED TO EMERGENCY RESPONSE PLAN
Dear Ms. Manzione:
By letter dated March 30, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17115A431), as supplemented on April 13, October 6, December 21 and 22, 2017; and February 23, 2018 (ADAMS Accession Nos. ML17109A386, ML17310A218, ML17362A097, ML18011A158, and ML18058A617, respectively), Holtec International submitted to the U.S. Nuclear Regulatory Commission (NRC) an application for a specific independent spent fuel storage installation license to construct and operate the HI-STORE Consolidated Interim Storage Facility (CISF), in Lea County, New Mexico, in accordance with the requirements of Part 72 of Title 10 of the Code of Federal Regulations, Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste and Reactor-Related Greater than Class C Waste. The license application seeks NRC approval to store up to 8,680 metric tons of commercial spent nuclear fuel in the HI-STORM UMAX Canister Storage System for a 40-year license term.
By letter dated September 13, 2018, the staff issued requests for additional information (RAIs)
(First Request for Additional Information, Part 2; ADAMS Accession No. ML18257A240) in connection with its review of the Emergency Response Plan for the HI-STORE CISF. By letter dated January 31, 2019 (ADAMS Accession No. ML19037A280), Holtec provided responses to the staffs request. The staff has reviewed your responses to staffs RAIs and determined that it needs additional clarification and/or supplementation of your responses to complete its review.
The information needed by the staff is discussed in the enclosure. We request that you provide responses within 60 days from the date of this letter. If you are unable to meet these deadlines, please notify NRC staff in writing, within two weeks of receipt of this letter, of your new submittal date and the reasons for the delay.
K. Manzione 2
Please reference Docket No. 72-1051 and CAC/EPID No. 001028/L-2018-NEW-0001 in future correspondence related to the technical review for this licensing action. If you have any questions, please contact me at (301) 415-0606.
Sincerely,
/RA/
Jose R. Cuadrado, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1051 CAC/EPID Nos.: 001028/L-2018-NEW-0001
Enclosure:
Request for Clarification of Holtecs Responses to First Request for Additional Information, Part 2
K. Manzione 3
SUBJECT:
HOLTEC INTERNATIONALS APPLICATION FOR SPECIFIC INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE FOR THE HI-STORE CONSOLIDATED INTERIM STORAGE FACILITY FOR SPENT NUCLEAR FUEL - REQUEST FOR CLARIFICATION OF RESPONSES RELATED TO EMERGENCY RESPONSE PLAN DOCUMENT DATE: December 26, 2019 DISTRIBUTION:
DFM r/f AKock, NMSS CRegan, NMSS EHouseman, OGC JNguyen, NMSS JCaverly,NMSS ADAMS No. ML19360A047 OFFICE DFM DFM NSIR NSIR NAME JCuadrado WWheatley JArce MNorris DATE 12/17/19 12/18/19 12/18/19 12/18/19 OFFICE NSIR DFM NAME JAnderson DDoyle DATE 12/18/19 12/19/19 OFFICIAL RECORD COPY
Enclosure Request for Clarification of Holtecs Responses to First Request for Additional Information, Part 2 Docket No. 72-1051 Application for Specific Independent Spent Fuel Storage Installation License for the HI-STORE Consolidated Interim Storage Facility in Lea County, New Mexico By letter dated March 30, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17115A431), as supplemented on April 13, October 6, December 21 and 22, 2017; and February 23, 2018 (ADAMS Accession Nos. ML17109A386, ML17310A218, ML17362A097, ML18011A158, and ML18058A617, respectively), Holtec International (Holtec) submitted to the U.S. Nuclear Regulatory Commission (NRC) an application for a specific independent spent fuel storage installation (ISFSI) license to construct and operate the HI-STORE Consolidated Interim Storage (CIS) Facility, in Lea County, New Mexico, in accordance with the requirements of Part 72 of Title 10 of the Code of Federal Regulations (10 CFR Part 72), Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste and Reactor-Related Greater than Class C Waste.
The license application seeks NRC approval to store up to 8,680 metric tons of commercial spent nuclear fuel in the HI-STORM UMAX Canister Storage System for a 40-year license term.
By letter dated September 13, 2018, the staff issued requests for additional information (RAIs)
(First Request for Additional Information, Part 2; ADAMS Accession No. ML18257A240) in connection with its review of the Emergency Response Plan for the HI-STORE CISF. By letter dated January 31, 2019 (ADAMS Accession No. ML19037A280), Holtec provided responses to the staffs request. The staff has reviewed Holtecs responses to staffs RAIs and determined that it needs additional clarification and/or supplementation of Holtecs responses to complete its review. The information required by staff is discussed below:
Emergency Response Plan (ERP) (Report No. HI-2177535, Revision 3)
RAI EP-3-S: Justify the inclusion of additional Emergency Action Levels (EALs) into the ISFSI EAL scheme for the HI-STORE CISF Emergency Response Plan (ERP)
In its response to RAI EP-3, the applicant revised Table 3.1.B of the ERP, CIS Facility Malfunction Initiating Condition Matrix, to accommodate the conditions/requirements listed in the Nuclear Energy Institute (NEI) document, NEI 99-01, Revision 6, Development of Emergency Action Levels for Non-Passive Reactors, dated November 21, 2013 (ADAMS Accession No. ML13091A209).
Although Table 3.1B, and Appendix C, Facility Emergency Action Levels, have been revised to incorporate the guidance of NEI 99-01, Revision 6, some of the emergency action levels (EALs) added to the table are more applicable to a non-passive light water reactor and are not consistent with the guidance for an ISFSI.
The guidance in Section 8 of NEI 99-01-, Revision 6, states, in part:
E-HU1, Damage to a loaded cask CONFINEMENT BOUNDARY, covers the spectrum of credible natural and man-made events included within the scope of an ISFSI design.
2 Table 3.1B of the ERP includes a proposed E-HU1 EAL, similar to that provided in Section 8 of NEI 99-01, Rev. 6. In addition, the Basis discussion for E-HU1 in Section 8 of NEI 99-01 provides for the inclusion of security-related events for ISFSIs, which the applicant included in Table 3.1B of the ERP as proposed H-HU1 and H-HA1. However, the following EALs proposed in Table 3.1B are not described in Section 8 of NEI 99-01, Revision 6:
H-HU2 - Seismic event greater than OBE [operating basis earthquake],
H-HU3 - Hazardous event, H-HU4 - Fire potentially degrading the level of safety of the facility, and H-HA6 - Primary Alarm Station evacuation resulting in transfer of plant control to alternate locations.
This information is necessary to determine compliance with 10 CFR 72.32(a)(3).
RAI EP-5-S: Provide justification why the duties of the Site Emergency Director (SED),
identified in Section 4.3.3 of the ERP, do not include the notification to the offsite response organizations and the NRC for the declaration of an Unusual Event classification.
In its response to RAI EP-5, the applicant updated Section 4.2.1 of the ERP to remove the list of duties, and to include a statement referencing Section 4.3.3 [Site Emergency Director (SED)] for the list of duties for the Site Emergency Director. This list of duties was revised to include decision to declare an Unusual Event and decision to escalate to an Alert. Specifically, Section 4.3.3 states, in part:
These duties include:
Decision to declare an Unusual Event Decision to escalate to an Alert.
Activation of onsite emergency response organization.
Prompt notification of offsite response authorities to inform them that an Alert has been declared (normally within 15 minutes of declaring an Alert).
Notification to the NRC Operations Center at 301-816-5100 immediately after notification of offsite authorities, and in any case within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of the declaration of an Alert.
Although the regulations only require the Alert classification, the proposed ERP proposes a classification for an Unusual Event. However, the SED duties do not include a notification to the offsite response organizations and the NRC for the declaration of an Unusual Event classification.
This information is necessary to determine compliance with 10 CFR 72.32(a)(3).
RAI EP-24-S: Supplement the Appendix D of the proposed ERP to address the following observations:
- 1. There are no agreements in Appendix D, or a commitment to establish such agreements, for the Maljamar, New Mexico; Monument, New Mexico, and Eunice City Fire Departments.
- 2. While there is an agreement with the Eddy County Fire Service, this agency is not identified as a responder in the ERP.
3
- 3. While there is an agreement in Appendix D for Lea Regional Medical Center, there are no agreements, or a commitment to establish such agreements, for the Carlsbad Medical Center or Permian Regional Medical Center.
- 4. There is no agreement in Appendix D, or a commitment to establish such agreement, for the City of Hobbs Ambulance Service.
- 5. There are no agreements, or a commitment to establish such agreements, in Appendix D for the Eddy County Sheriffs Department, nor the New Mexico State Police.
In its response to RAI EP-24, the applicant included appropriate MOUs [memoranda of understanding] as an appendix to the Emergency Response Plan. However, in several sections of the proposed ERP, the applicant identifies several additional organizations with emergency response responsibilities for which an MOU, or a commitment to establish such agreement, has not been provided. The specific organizations and ERP sections referenced are discussed below:
Section 4.3.11, Local Off-site Assistance, states the following:
The Maljamar Fire Department in Maljamar, New Mexico is located approximately 28 miles from the site. The Monument, New Mexico and the Eunice, New Mexico Fire Departments are located 36 miles and 38 miles respectively from the CIS Facility. Each of these departments are equipped to respond to structural fires, oil well fires, and chemical tank explosions.
Section 5.3.1 Mitigation of Fires, states, The Eunice Fire Department may also respond and is also known for fighting large fires and has worked with other firefighting teams in the field. Radiological response training will be offered to the Maljamar, New Mexico, Monument, New Mexico, and Eunice City Fire Department as a precaution.
Section 4.3.11 further provides the following:
Carlsbad Medical Center, located in Carlsbad, New Mexico is the first choice for incidents involving radiologically contaminated individuals; unless life threatening injuries are present. Life threatening injuries would be treated at Lea Regional Medical Center or Permian Regional Medical Center.
Section 4.3.11 further provides the following:
The City of Hobbs, New Mexico has ambulance service available for the CIS Facility.
Ambulance services are capable of handling incidents involving radiologically contaminated individuals.
Section 5.3.1, further states in part,
[]the Lea and Eddy County Sheriffs Departments and/or the New Mexico State Police are responsible for directing traffic and limiting access of the general public to the affected area.
4 This information is necessary to determine compliance with 10 CFR 72.32(a)(15).