Letter Sequence Request |
|---|
EPID:L-2017-NEW-0002, Interim Storage Partners (ISP) First Request for Additional Information (RAI) Proposed Submittal Schedule, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 (Open) CAC:001028, SR 3.5.1.2 Notation (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement
Results
Other: ML19150A559, ML19156A038, ML19156A039, ML19156A041, ML19156A042, ML19156A044, ML19182A107, ML19184A160, ML19184A161, ML19184A163, ML19184A164, ML19190A182, ML19190A183, ML19190A185, ML19190A187, ML19211D027, ML19217A210, ML19217A211, ML19217A212, ML19217A213, ML19217A214, ML19217A215, ML19217A216, ML19235A149, ML19235A150, ML19235A153, ML19235A154, ML19235A156, ML19255E791, ML19255E795, ML19268A116, ML19283B557, ML19337B504, ML19337B505, ML19337B506, ML19337B508, ML19337B509, ML19337B512, ML19337B514, ML19337B515, ML19337B516, ML19337B517, ML19337B518, ML20015A450, ML20015A451, ML20015A453, ML20015A454, ML20028D891, ML20028D892, ML20028D893... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A6082018-02-23023 February 2018 HI-2177593, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Underground CISF - Financial Assurance & Project Life Cycle Cost Estimates Project stage: Request ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI 2018-01-11
[Table View] |
Text
OpenPortionoftheMeeting TechnicalDiscussion January10,2019 WCSCISFNRCRAIPart1Meeting
Purpose and Agenda
- Discuss several first RAIs, Part 1
RAI NP-2.4-3 3
- Provide clarification as to what is the exact design of WCS CISF rail side track, in particular the section east of the storage area.
- Figures in Chapter 1 of the SAR are consistent with the flood plain analysis.
- State that the design of the WCS CISF rail side track is consistent with the flood plain analysis and as shown in Figure 2-35 of the SAR.
- The figures in Chapter 2 in question that show the rail in a slightly different position will be updated to indicate that the rail is shown for orientation purposes only and point to Figure 2-35.
RAI NP-15-1
- 1. Provide an applicable reference for minimal corrosion of the DSC shells during an 80-year exposure to a severe marine environment
- During the preparation of the CoC 1029 application TN Americas LLC was requested, by the lead utility, to prepare a calculation describing the expected life of the various NUHOMS components proposed for use at San Onofre Nuclear Generating Station.
This calculation prepared in 2002 shows a life expectancy of various stainless steels for the DSC shell is greater than 100 years for the worst case assumed marine environment (Kure Beach, NC data).
- ISP will provide a copy of the calculation prepared in 2002 - Suitability of Materials for a Dry Storage Facility for 100 Years Service in a Marine Atmosphere Environment 4
RAI NP-15-1
- 2. Clarify the range of environmental conditions expected for the DSC internals
- Revise statement as follows: The DSC internals are enveloped in a dry, helium-inerted environment and are designed to withstand the loads from all normal, off-normal and accident conditions.
5
RAI NP-15-1
- 3. Clarify the design life of 80 years for the HSM given reference UFSARs provide varying design lives.
- The differences in the reported life expectancy between the Rancho Seco Site license and the general licenses for CoC 1004 and CoC 1029 can be explained by the time frame in which each was written and the purpose for each.
- Suitability of Materials for a Dry Storage Facility for 100 Years Service in a Marine Atmosphere Environment also provides evaluations for the materials used for HSMs.
6
RAIs NP-15-2, NP-15-3, NP-15-4, and NP-15-9
- The CISF application includes Appendix H on the Canistered GTCC Waste to be stored.
- It incorporates the systems that currently are part of approved UFSAR documents from the sites that store GTCC.
- There are pointers in Appendix H to specific SARs that are incorporated in our application.
- RAI NP-15-2 seems to go beyond information needed for the MP-187 system (and beyond the GTCC canister) since our application includes all information from the currently approved license at that facility.
- RAI NP-15-4 and NP-15-9 seem to ask for information that is already included in the application.
7
RAI NP-15-4
- RAI NP-15-4 asks for the complete set of drawings for the GTCC canisters currently stored atMY...and for the applicable codes and standards for the design and construction of these casks, noting that the drawings in Appendix H are only of the MPC, not the basket or the contents.
- With respect to contents, Appendix H.3.1.1 specifically states that the GTCC waste is described in the NAC-UMS transportation cask SAR, Section 1.3.1.1.2, and lists the reference.
- That reference details the contents (isotopes) and identifies the table that presents the source terms and the location of the drawings, the structural evaluation of the basket, its thermal evaluation, the containment and shielding evaluations. The waste does not contain any significant fissile material.
8
RAI NP-15-4
- RAI NP-15-4 Maine Yankee (MY) Example (Continued)
- The waste basket is pointed out in SAR Section H.4.8 as Sheets 1 through 2 of Section 1.3.4 of the SAR for the UMS Universal Transport Cask. These drawings show the GTCC Waste Basket and identify the Codes.
- The application addresses the identical question for MY, CY, Rowe, and Zion.
9
RAIs NP-15-2, NP-15-3, NP-15-4, and NP-15-9
- The RAIs state that information is needed to determine compliance with 72.24.
- It is our understanding that ISG-17 defines what is required to comply with 72.24.
- We have incorporated by reference the existing SF systems currently approved by NRC at Rancho Seco (includes GTCC), San Onofre, MY, CY, Rowe, and Zion, as well as the SF system at Lacrosse.
- The canisters that will be stored are the ones that are currently in use at these locations.
- RAI NP-15-2 requests information that is not included in the application as it was not included as part of the approval for the SMUD site specific license.
Appendix H provides the same level of detail provided in Appendix C of the SMUD UFSAR for all GTCC canisters included in this application.
10
RAIs NP-15-2, NP-15-3, NP-15-4, and NP-15-9
- Information requested in RAIs 15-4 and 15-9 appears to be already provided.
- RAI NP-15-2 appears to request information beyond what was required for the NRC to approve the DSCs, Transfer Cask (MP-187) and GTCC canisters in the SMUD site specific license.
- For RAI NP-15-3, ISP has provided information related to the GTCC canister and contents to the same level of detail as that provided in the SMUD site specific license used by the NRC to approve the SMUD site specific license.
- Much material that is presented already exceeds a strict conventional reading of ISG-17.
11
RAIs NP-15-2, NP-15-3, NP-15-4, and NP-15-9
- We want to be sure we understand these RAIs properly.
- If information different from that provided is needed, we request that these RAIs be withdrawn or revised as needed.
- RAIs seem to requests information beyond that which was required by the NRC in the past. As these canisters are already in use under existing dockets, adding new information impacts the incorporation by reference structure of our application.
12
RAI NP-15-13
- Incorporate the approved aging management programs for the NUHOMS-61BT and NUHOMS-61BTH Type 1 DSCs that are part of CoC No. 1004.
- In accordance with the proposed license condition 20(1) The Licensee shall commit to the AMPs committed to in the approved License Renewal of CoC 1004 for all NUHOMS Spent Fuel Canisters and storage overpacks. Interim Storage Partners (ISP) has incorporated in each applicable Appendix (Appendix A - D) the applicable AMPs from the Renewed CoC 1004 for all NUHOMS DSCs and HSMs.
13
RAI NP-15-13
- ISP Planned Approach Continued
- Include discussion for why CoC No 1004 AMPs bound the NUHOMS-MP187 Cask System
- HSM Model 80 included in CoC No 1004
- Reviewed and documented the evaluation of the subcomponents of the FO, FC, FF &
GTCC DSCs and compare them to corresponding DSC subcomponents evaluated in the Renewed CoC 1004 and concluded that no aging management activity (AMA) is required, or that the AMPs in CoC 1004 are applicable.
- Include discussion for why CoC No 1004 AMPS bound the Standardized Advanced NUHOMS System
- Reviewed and documented the evaluations of the subcomponents of the 24PT1 DSCs and AHSM and compared them to corresponding DSC and HSM subcomponents evaluated in the Renewed CoC 1004 and concluded that no aging management activity (AMA) is required, or that the AMPs in CoC 1004 are applicable
- Note the HSM Model 152 (AHSM without ties) included in CoC No 1004 14
RAI NP-15-13
- ISP Planned Approach Continued
- The following changes are made to the AMPs from CoC No. 1004 to reflect operation at the WCS CISF:
- Rearranged program element requirements to align with NUREG-1927 Rev 1.
- Did not include the high burnup (HBU) AMP - not authorized for NUHOMS Systems
- Did not include the Transfer Cask AMPs
- Explanation/ Justification - The Part 71 transportation casks used to transport the DSCs from the originating ISFSIs to the WCS CISF will also be used to transfer the DSCs from the cask handling building to the HSMs. The inspections and maintenance performed on the transportation casks (i.e., to ensure the casks meet the Part 71 requirements) will be relied upon to ensure the casks are able to perform their intended functions as transfer casks. Therefore, no Part 72 Transfer Cask AMP is required.
- Removed references to renewal and the CoC 1004 Amendments
- Defined extended period of operation
- Changed reference from Part 50 Appendix B program to TN Americas 10 CFR Part 72, Subpart G Program 15
RAI NP-15-13
- ISP Planned Approach Continued
- The following changes are made to the AMPs from CoC No. 1004 to reflect operation at the WCS CISF:
- Changed reference from general licensees to ISP
- Removed reference to 72.212 report
- Clarified that minimum DSCs for inspection are from each originating ISFSI
- Removed reference to Standardized NUMOMS dry storage system
- Removed sentence for licensees not committed to ACI 349.3R
- Various editorial changes
- Various editorial changes were made to improve readability of the AMPs and to reflect that ISP is responsible for implementing the AMPs rather than a general licensee.
16
RAI EP-6
- Clarify the individual on site at all times with the authority and responsibility to accurately and timely perform emergency classification and notify offsite agencies and the NRC.
- It is our understanding that there is no requirement that the person with the responsibility to accurately and timely perform emergency classification and notify offsite agencies and the NRC to be on site.
- The IC or alternate is either on site or on call 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day and can perform his/her duties while off site.
- The security officer stationed at the CAS has the responsibility to contact the IC immediately who then makes the required determinations and notifications.
17
RAI EP-20
- Justify the Alert criteria and dose thresholds used for the radiological plume incident in Appendix C.
- The information included in Appendix C of the ISP Draft CERP is for the existing WCS Storage, Processing and Disposal Facility and does not apply to the WCS CISF.
- The CERP will be updated to specify the facility (WCS CISF or WCS Storage, Processing and Disposal Facility) to which each section applies.
- In addition, the information will be updated to the NRC-endorsed EAL guidance.
18
ClosedPortionoftheMeeting TechnicalDiscussion January10,2019 WCSCISFNRCRAIPart1Meeting
RAI P-2.6-2
- Criteria for Backfill Compaction and Quality Control
- Provide reference in the SAR to the backfill compaction and quality control requirements in Section 4.2.2 Structural Soil Fill of Attachment E to SAR Section 7.6.2.1.
20
RAI P-2.6-5
- Justify why the selected stratum depth of is adequate for evaluating settlement at the WCS CISF
- The selected stratum depth is the shallowest auger refusal depth (obtained in boring B-101). Borehole auger refusal depths are from boreholes B-101, B-111, TF-1, and TF-4.
- Seismic data (shear wave velocities) to 100 feet provide confirmation that significant settlement does not occur below auger refusal.
21
Thank-you for your time 22