Letter Sequence Meeting |
|---|
CAC:001028, (Approved, Closed) EPID:001028, Package: Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) (Approved, Closed) EPID:L-2018-LRM-0051, License Renewal (Open) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577, ML18324A594... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML18030A1722018-01-29029 January 2018 Letter to J. P. Zimmerman Request for Additional Information for the Technical Review of the Application for Renewal of the Three Mile Island Unit 2 Independent Spent Fuel Storage Installation License No.: SNM-2508 Project stage: RAI ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2212018-02-0606 February 2018, 8 February 2018 Package: Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Request ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18040A0502018-02-0606 February 2018 Conversation Record with Dominion Energy Virginia Discuss North Power Station (NAPS) Independent Spent Fuel Storage Installation (ISFSI) Technical Specification Project stage: Other ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18058A6082018-02-23023 February 2018 HI-2177593, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Underground CISF - Financial Assurance & Project Life Cycle Cost Estimates Project stage: Request ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI 2018-01-16
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 14, 2018 MEMORANDUM TO: Michael C. Layton, Director Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards FROM:
Kristina L. Banovac, Project Manager
/RA/
Renewals and Materials Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards
SUBJECT:
SUMMARY
OF NOVEMBER 7, 2018, MEETING WITH GE-HITACHI NUCLEAR ENERGY AMERICAS, LLC TO DISCUSS THE UPCOMING SUBMITTAL OF THE APPLICATION FOR RENEWAL OF THE MORRIS INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE (SNM-2500) (CAC/EPID NOS. 001028/L-2018-LRM-0065)
=
Background===
On November 7, 2018, a meeting was held in Rockville, MD, between representatives of GE-Hitachi Nuclear Energy Americas, LLC (GEH) and the U.S. Nuclear Regulatory Commission (NRC) to discuss the upcoming submittal of the application for renewal of the Morris Independent Spent Fuel Storage Installation (ISFSI) license (SNM-2500). The list of meeting attendees is provided in Enclosure 1.
The meeting was noticed on October 17, 2018 (Agencywide Documents Access and Management System Accession No. ML18291A681).
Discussion The meeting discussion followed the meeting agenda, which is provided in Enclosure 2. GEHs presentation is provided in Enclosure 3. GEH provided an overview of the Morris ISFSI operations and the planned license renewal application. The Morris ISFSI is the only wet storage facility licensed under 10 CFR Part 72. GEH noted the static nature of the facility and that no fuel movements have occurred since the initial placement of fuel in the fuel storage basin. The license for the Morris ISFSI (SNM-2500) was previously renewed for a 20-year term, and the current expiration date is May 31, 2022. The timely renewal due date for the submittal of the renewal application is May 31, 2020. GEH plans to submit the renewal application in the first quarter of 2020 and plans to request an additional 20-year term. GEH noted it is in the early planning stages for the renewal application, and it may request a second pre-application meeting with the NRC staff after it further develops the application, potentially in fall 2019.
CONTACT: Kristina Banovac, NMSS/DSFM (301) 415-7116
The following items were discussed between GEH and NRC representatives during the meeting:
GEH clarified several aspects of the Morris ISFSI design bases: (1) material stored includes spent fuel from multiple sites, both boiling-water reactor and pressurized-water reactor spent fuel, and zircaloy clad and stainless steel clad spent fuel; (2) water chemistry is maintained within approved technical specifications through filtration and addition of ultra pure water; (3) criticality control is based on geometry and the configuration of the basin, baskets, and fuel; neutron absorbers and borated water are not used; and (4) the accident analyses are in Chapter 8 of the final safety analysis report (which is called the Consolidated Safety Analysis Report (CSAR) for the Morris ISFSI), and include analysis of a tornado-generated missile accident.
The NRC staff asked about the confinement boundary. GEH noted that the fuel cladding is considered the primary confinement barrier, and the basin is the secondary confinement barrier. The NRC staff noted that if the confinement boundary is not clear in the CSAR, GEH can clarify this in the renewal application.
The NRC staff asked what structures, systems, and components (SSCs) are necessary to ensure retrievability at the end of storage, and how these will be considered in the renewal application. GEH noted that these SSCs include equipment (e.g., cranes, grapples) for moving fuel bundles or fuel baskets; this equipment is laid away and will be inspected prior to use.
The NRC staff noted that in the license renewal application, GEH may summarize the changes made to the CSAR (e.g., via 10 CFR 72.48 changes) since the last biennial submittal, or it may submit the current version of the CSAR (even if outside the biennial submittal window) to reflect the current design bases to support the renewal application.
The NRC staff noted that although NUREG-1927, Revision 1 (Standard Review Plan for Renewal of Specific Licenses and Certificates of Compliance for Dry Storage of Spent Nuclear Fuel) is not intended to be used for the review of renewal applications for wet storage facilities, it still contains guidance that is relevant to the renewal application for the Morris ISFSI. Chapter 1 contains guidance on the general information to be included in a 10 CFR Part 72 renewal application; Chapter 2 contains guidance on determining what SSCs are within the scope of renewal; and Chapter 3 contains guidance on the aging management review, including guidance on time-limited aging analyses and the elements of an aging management program (AMP).
The NRC staff also noted that, similar to the review of the first Morris renewal application, it will use applicable guidance in NUREG-1801 (Generic Aging Lessons Learned (GALL)
Report), related to wet spent fuel storage facilities.
The NRC staff noted that the license renewal application should include an evaluation of any relevant operating experience, including results from surveillances and AMP inspections at the Morris ISFSI and wet storage facilities in general, to inform the proposed AMPs.
Operating experience is considered element 10 of an AMP.
GEH noted that it will submit an updated environmental report, showing any changes to the affected environment. The NRC staff noted that the environmental report should discuss the
potential environmental impacts of any aging management activities proposed in the renewal application.
GEH noted that its next triennial submittal of the decommissioning funding plan, per 10 CFR 72.30(c), is due in December 2018. The submittal will include updates since the 2015 submittal, such as the change in the financial assurance mechanism. The NRC staff clarified that 10 CFR 72.30(c) requires a decommissioning funding plan update to be submitted at the time of renewal. The NRC staff noted that if there are no changes to the latest docketed decommissioning funding plan submittal, GEH can reference the previous submittal in its renewal application. The NRC staff also noted for GEH awareness that the draft proposed rule on Regulatory Improvements for Production and Utilization Facilities Transitioning to Decommissioning (SECY-18-0055, ADAMS Accession No. ML18012A019) contains proposed changes to 10 CFR 72.30(c); the draft proposed rule is currently with the Commission for its review and approval.
After GEH and NRC representatives completed their discussion, the meeting was opened to public comments or questions. There were no questions or comments from the public attendee.
Action Items/Next Steps GEH may request a second pre-application meeting in the fall 2019 timeframe when it is further along with the development of its license renewal application. GEH plans to submit the renewal application in the first quarter 2020.
Docket No. 72-01 CAC/EPID Nos. 001028/L-2018-LRM-0051
Enclosures:
- 1. Meeting Attendees
- 2. Agenda
- 3. Handout - GEH Presentation on Morris SNM-2500 License Renewal
SUBJECT:
SUMMARY
OF NOVEMBER 7, 2018, MEETING WITH GE-HITACHI NUCLEAR ENERGY AMERICAS, LLC TO DISCUSS THE UPCOMING SUBMITTAL OF THE APPLICATION FOR RENEWAL OF THE MORRIS INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE (SNM-2500) (CAC/EPID NOS. 001028/L-2018-LRM-0065), DOCUMENT DATE: November 14, 2018 DISTRIBUTION:
NMSS/DSFM R/F RidsOpaMail Resource NMSS_DSFM_RMB Distribution JMcKirgan, NMSS TTate, NMSS DTang, NMSS ARigato, NMSS JIreland, NMSS CKenny, NMSS MKunowski/RIII REdwards, RIII JDalzell, RIII G:\\SFST\\GE Morris\\License Renewal (Subsequent)\\11-7-18 Public Meeting\\11-7-18 GEH Morris renewal meeting summary.docx ADAMS Package No.: ML18319A255 Memo: ML18319A256 : ML18319A257 OFFICE NMSS/DSFM NMSS/DSFM NMSS/DSFM NAME KBanovac WWheatley MRahimi DATE 11 / 8 / 18 11 / 13 / 18 11 / 14 / 18 OFFICIAL RECORD COPY
MEETING ATTENDEES Meeting with GE-Hitachi Nuclear Energy Americas, LLC to discuss the upcoming submittal of the application for renewal of the Morris Independent Spent Fuel Storage Installation license (SNM-2500)
November 7, 2018, 1:00 p.m. - 3:00 p.m.
Kristina Banovac NRC/NMSS/DSFM/RMB Tae Ahn NRC/NMSS/DSFM/RMB David Tarantino (via teleconference)
NRC/NMSS/DSFM/RMB John Wise (via teleconference)
NRC/NMSS/DSFM/RMB John McKirgan NRC/NMSS/DSFM/SFLB Travis Tate NRC/NMSS/DSFM/CSRAB David Tang NRC/NMSS/DSFM/CSTB Antonio Rigato NRC/NMSS/DSFM/CSTB JoAnn Ireland (via teleconference)
NRC/NMSS/DSFM/CSTB Caylee Kenny (via teleconference)
NRC/NMSS/DSFM/CSTB Mike Kunowski (via teleconference)
NRC/Region III Rhex Edwards (via teleconference)
NRC/Region III Jennifer Dalzell (via teleconference)
NRC/Region III Scott Murray GEH Bobbie Lockwood GEH Tony McFadden GEH Franklin Bo Partney (via teleconference)
GEH Jamie Wilkey (via teleconference)
GEH Robert Haimer (via teleconference)
American Electric Power
MEETING AGENDA Meeting with GE-Hitachi Nuclear Energy Americas, LLC (GEH)
November 7, 2018 1:00 p.m. - 3:00 p.m. (Eastern Standard Time)
One White Flint North Building, Room O-16D3
Purpose:
Meeting with GEH to discuss the upcoming submittal of the application for renewal of the Morris Independent Spent Fuel Storage Installation license (SNM-2500)
Agenda:
Welcome, introductions, and meeting objectives GEH presentation and discussion Public questions or comments Wrap-up and closing remarks Meeting adjourned
HANDOUTS