CAC:000993, (Approved, Closed) CAC:001028, (Approved, Closed) EPID:L-2018-LNE-0004, Independent Spent Fuel Storage Installation - Submittal of Application for the License Renewal (Approved, Closed) EPID:L-2018-RNW-0005, Independent Spent Fuel Storage Installation - Submittal of Application for the License Renewal (Approved, Closed) |
Results
Other: ML18101A024, ML18108A052, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18222A351, ML18303A232, ML19112A158, ML19121A263, ML19121A265, ML19121A267, ML19121A268, ML19184A181, ML19184A184, ML19184A186, ML19184A187, ML19204A242, ML19204A244, ML19204A248, ML19204A251, ML19259A012, ML20065N277, ML20065N278, ML20065N280, ML20065N281, ML20065N285, ML22089A167
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI ML18058A6082018-02-23023 February 2018 HI-2177593, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Underground CISF - Financial Assurance & Project Life Cycle Cost Estimates Project stage: Request ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request 2018-01-11
[Table View] |
Text
DPG 18-114 Page 1 of 4 June 25, 2018 Attn: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket 72-11 Rancho Seco Independent Spent Fuel Storage Installation License No. SNM-2510 RESPONSE TO REQUEST FOR SUPPLEMENTAL INFORMATION FOR ACCEPTANCE REVIEW OF THE APPLICATION FOR THE RENEWAL OF 10 CFR PART 72 SPECIAL NUCLEAR MATERIALS LICENSE NO. SNM-2510 FOR THE RANCHO SECO INDEPENDENT SPENT FUEL STORAGE INSTALLATION (CAC/EPID NOS. 001028/L-2018-RNW-0005;000993/L-2018-LNE-0004)
Reference:
Letter from Wendy A. Reed (NRC) to Dan Tallman (SMUD), REQUEST FOR SUPPLEMENTAL INFORMATION FOR ACCEPTANCE REVIEW OF THE APPLICATION FOR RENEWAL OF THE RANCHO SECO INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE NO. SNM-2510 (CAC/EPID NOS. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004),
dated May 29, 2018
Dear Mr. Layton:
This submittal provides responses to the Request for Supplemental Information (RSI) forwarded by the letter referenced above. Enclosure 2 herein provides responses to the RSI items and nearly all Observation (OBS) items. Each RSI and OBS response has an impact section that describes any changes made to the Rancho Seco ISFSI License Renewal Application (LRA) as a result of the RSI or OBS. Enclosure 3 provides a proprietary version of the entire LRA, updated to Revision 1. Enclosure 4 provides a public version of the entire Revision 1 LRA. Enclosures 5 through 9 provide proprietary calculations that are requested by RSIs 2, 3, and 4. Changes in the Revision 1 LRA are tracked and indicated by revision bars. All changes are based on the RSI and OBS responses.
Enclosures transmitted herein contain SUNSI. When separated from enclosures, this transmittal document is decontrolled.
Powering forward. Together.
DPG 18-114 Page 2 of 4 Certain portions of this submittal include proprietary information, which may not be used for any purpose other than to support the NRC staffs review of the LRA. In accordance with 10 CFR 2.390, TN Americas LLC is providing an affidavit (Enclosure 1) specifically requesting that this proprietary information be withheld from public disclosure. Because the Enclosures 5 through 9 calculations are entirely proprietary, public versions are not included.
This submittal is being provided as an electronic submission, using the optical storage media (OSM) provision from Section 4 of the NRC Guidance for Electronic Submissions to the NRC.
Accordingly, we have included a Document Components listing and OSM#l and OSM#2 listings at the end of this cover letter.
SMUD is submitting this license renewal application update under oath or affirmation (Enclosure 10). Accordingly, pursuant to 10 CFR 72.16(b ), I declare under penalty of perjury that the information contained in SMUD letter DPG 18-114, "RESPONSE TO REQUEST FOR SUPPLEMENTAL INFORMATION FOR ACCEPTANCE REVIEW OF THE APPLICATION FOR THE RENEWAL OF 10 CFR PART 72 SPECIAL NUCLEAR MATERIALS LICENSE NO. SNM-2510 FOR THE RANCHO SECO INDEPENDENT SPENT FUEL STORAGE INSTALLATION (CAC/EPID NOS. 001028/L-2018-RNW-0005;000993/L-2018-LNE-0004)"
is true and correct to the best of my knowledge.
Should you have questions or require additional information, please contact me directly at (916) 73 2-4893.
Sincerely, Dan Tallman Manager, Rancho Seco Asset Ra ncho Se co N uclea r Ge ne rat ing Station I 14440 Twin Ciues Road I He rald. CA 95638-9799 I 1. 209.333.2935 smucl. org
DPG 18-114 Page 3 of 4
Enclosures:
- 1. TN Americas LLC Affidavit Pursuant to 10 CFR 2.390
- 2. RSIs and Observations and Responses
- 3. Rancho Seco ISFSI License Renewal Application, Revision 1 (proprietary version)
- 4. Rancho Seco ISFSI License Renewal Application, Revision 1 (non-proprietary version)
- 5. TN Calculation 502917-AMR03, Revision 0 (Proprietary)
- 6. TN Calculation 502917-0501, Revision 0 (Proprietary)
- 7. TN Calculation 502917-0201, Revision 1 (Proprietary)
- 8. TN Calculation 502917-0200, Revision 0 (Proprietary)
- 9. TN Calculation 502917-0500, Revision 0 (Proprietary)
- 10. California All Purpose Acknowledgment of SMUD Affirmation Pursuant to 10 CFR 72.16(b) cc: Wendy Reed, NRC - five electronic copies of the entire submittal (i.e., five OSM#1 disks)
William Allen, NRC, (w/o enclosures)
Meraj Rahimi, NRC, (w/o enclosures)
Administrator, NRC Region IV (w/o enclosures)
Radiological Health Branch of the California State Department of Health Services (w/o enclosures)
DPG 18-114 Page 4 of 4 Document Components:
001 Public Transmittal Letter.pdf, 1,179,958 bytes 002 Public Encl 1 TN Affidavit.pdf, 513,077 bytes 003 Public Encl 2 RSI and OBS responses.pdf, 139,117 bytes 004 SUNSI Encl 3 LRA proprietary version.pdf, 39,723,922 bytes, Proprietary 005 Public Encl 4 LRA public version.pdf, 40,069,370 bytes 006 SUNSI Encl 5 LRA TN Calc 502917-AMR03 R0.pdf, 14,080,233 bytes, Proprietary 007 SUNSI Encl 6 LRA TN Calc 502917-0501 R0.pdf, 12,908,834 bytes, Proprietary 008 SUNSI Encl 7 LRA TN Calc 502917-0201 R1.pdf, 2,329,648 bytes, Proprietary 009 SUNSI Encl 8 LRA TN Calc 502917-0200 R0.pdf, 5,350,755 bytes, Proprietary 010 SUNSI Encl 9 LRA TN Calc 502917-0500 R0.pdf, 12,336,954 bytes, Proprietary 011 Public Encl 10 CA Acknowledgment of SMUD Affirmation.pdf, 1,111,259 bytes OSM#1 (Entire Submittal) (Disk):
001 Public Transmittal Letter.pdf, 1,179,958 bytes 002 Public Encl 1 TN Affidavit.pdf, 513,077 bytes 003 Public Encl 2 RSI and OBS responses.pdf, 139,117 bytes 004 SUNSI Encl 3 LRA proprietary version.pdf, 39,723,922 bytes, Proprietary 005 Public Encl 4 LRA public version.pdf, 40,069,370 bytes 006 SUNSI Encl 5 LRA TN Calc 502917-AMR03 R0.pdf, 14,080,233 bytes, Proprietary 007 SUNSI Encl 6 LRA TN Calc 502917-0501 R0.pdf, 12,908,834 bytes, Proprietary 008 SUNSI Encl 7 LRA TN Calc 502917-0201 R1.pdf, 2,329,648 bytes, Proprietary 009 SUNSI Encl 8 LRA TN Calc 502917-0200 R0.pdf, 5,350,755 bytes, Proprietary 010 SUNSI Encl 9 LRA TN Calc 502917-0500 R0.pdf, 12,336,954 bytes, Proprietary 011 Public Encl 10 CA Acknowledgment of SMUD Affirmation.pdf, 1,111,259 bytes OSM#2 (Public Information Only) (Disk):
001 Public Transmittal Letter.pdf, 1,179,958 bytes 002 Public Encl 1 TN Affidavit.pdf, 513,077 bytes 003 Public Encl 2 RSI and OBS responses.pdf, 139,117 bytes 005 Public Encl 4 LRA public version.pdf, 40,069,370 bytes 011 Public Encl 10 CA Acknowledgment of SMUD Affirmation.pdf, 1,111,259 bytes