Letter Sequence Approval |
|---|
CAC:001028, SR 3.5.1.2 Notation (Approved, Closed) EPID:L-2021-LLA-0140, International, HI-STORM 100 Multipurpose Canister Storage System Amendment 17 Request (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577, ML18324A594... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18058A6082018-02-23023 February 2018 HI-2177593, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Underground CISF - Financial Assurance & Project Life Cycle Cost Estimates Project stage: Request ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI 2018-01-11
[Table View] |
Text
Enclosure 8 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 FINAL SAFETY EVALUATION REPORT DOCKET NO. 72-1014 HOLTEC INTERNATIONAL CERTIFICATE OF COMPLIANCE NO. 1014 HI-STORM 100 CASK SYSTEM AMENDMENT NO. 17
SUMMARY
This safety evaluation report (SER) documents the U.S. Nuclear Regulatory Commission (NRC) staffs review and evaluation of the amendment request to amend renewed Certificate of Compliance (CoC) No. 1014 for the HI-STORM 100 Cask System. By letter dated July 30, 2021, Holtec International (Holtec, the applicant) submitted an amendment to CoC No. 1014 to update the description of the system in the CoC and final safety analysis report (FSAR) to clarify that only the portions of multi-purpose canister (MPC) components that come into contact with the pool water need to be made of stainless steel or aluminum (Holtec 2021b). The previous description stated that MPC components that may come into contact with pool water are made entirely of stainless steel or aluminum. The amended CoC, when codified through rulemaking, will be denoted as renewed Amendment No. 17 to CoC No. 1014.
The staff's evaluation is based on a review of the applicants amendment application and whether it meets the applicable requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 72 for dry storage of spent nuclear fuel. The staffs evaluation focused on modifications requested in the amendment as supported by the submitted revised FSAR (see Attachment 3 of Holtec 2021b) and did not reassess previous revisions of the FSAR nor previous amendments to the CoC. In its review, the staff followed the guidance in NUREG-2215, Standard Review Plan for Spent Fuel Dry Storage Systems and Facilities (NRC 2020).
1.0 GENERAL DESCRIPTION The objective of this chapter is to review the changes requested to renewed CoC No. 1014 for the HI-STORM 100 Cask System to ensure that the applicant provided an adequate description of the pertinent features of the storage system and the changes requested in the application.
The applicant proposed to update the HI-STORM 100 system description in FSAR section 1.2.1.1, as well as the CoC, to clearly indicate that only the portions of the MPC components that come into contact with the pool water need to be made of stainless steel or aluminum. Staff reviewed the changes and determined that the changes to both the FSAR and CoC are editorial in nature. Staff also provided a more detailed evaluation of the change in section 8.0 of this SER. Based on a review of the application information, staff finds the change acceptable.
2.0 PRINCIPAL DESIGN CRITERIA The applicant did not propose any changes that affect the staffs previous evaluation of the principal design criteria that was provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
3.0 STRUCTURAL EVALUATION The applicant did not propose any changes that affect the staffs previous structural evaluation that was provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
4.0 THERMAL EVALUATION The applicant did not propose any changes that affect the staffs thermal evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos.
1 through 15. Therefore, the staff determined that a new evaluation was not required.
5.0 CONFINEMENT EVALUATION The applicant did not propose any changes that affect the staffs confinement evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
6.0 SHIELDING EVALUATION The applicant did not propose any changes that affect the staffs shielding evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
7.0 CRITICALITY EVALUATION
The applicant did not propose any changes that affect the staffs criticality evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos.
1 through 15. Therefore, the staff determined that a new evaluation was not required.
8.0 MATERIALS EVALUATION The objective of the staffs review is to evaluate whether the proposed clarification to the storage system description in the CoC and FSAR represents a change to the system design and, if so, evaluate the effects of the change on the ability of the storage system to meet the requirements of 10 CFR Part 72.
The staff reviewed the CoC and FSAR, including the associated drawings, and noted that the proposed changes have no effect on the system design as evidenced by:
The CoC and FSAR description updates proposed no changes to the drawings in section 1.5 of the FSAR. In addition, staff reviewed the drawings and determined that the description updates are consistent with the drawings because the drawings already note that the MPC lid may be either a one-piece design made entirely of stainless steel, or a two-piece design with the top part made entirely of stainless steel and the bottom part made of either stainless steel or carbon steel, with all surfaces that may come in contact with pool water coated or covered with stainless steel.
The CoC and FSAR description updates proposed no changes to the materials and components tables of FSAR section 2. In addition, staff reviewed the materials and components tables of FSAR section 2 and determined that they already identify that the bottom part of the MPC Lid two-piece design can be made of either stainless steel or carbon steel.
The staff had previously evaluated the possible use of carbon steel in MPC components, as evidenced by the NRCs description of the HI-STORM 100 Cask System provided in NUREG-2214, Managing Aging Processes in Storage (MAPS) Report (NRC 2019). Section 4.3.2 and table 4-7 of NUREG-2214 described the bottom portion of the two-piece lid having a material option of steel coated with stainless steel.
Finally, the staff considered whether the proposed revision would change the staffs prior conclusions for the renewal of CoC No. 1014 (NRC 2023). The staff verified that, in table 3.3-1 of the application for renewal, Aging Management Review of MPC Enclosure Vessel Subcomponents, the applicant appropriately evaluated the potential aging mechanisms and effects for the two-piece lid, including the option to use carbon steel on the bottom portion of the lid (Holtec 2021a). Consequently, the staff finds that the aging management activities approved for the renewed storage term for CoC No. 1014 remain adequate to ensure that structures, systems, and components (SSCs) will maintain their intended functions for the period of extended operation.
Based on the staffs review of the drawings, FSAR text, and CoC, the staff finds that the proposed change to the system description is consistent with the storage system design previously reviewed and approved by the staff. The applicant is proposing an editorial change to the CoC and FSAR that is consistent with the storage system materials of construction. The revision neither revised the system design, nor introduced new technical considerations that were not already considered in the staffs prior review of the HI-STORM 100 system. Therefore, the staff finds the revision to the CoC and FSAR to be acceptable.
9.0 OPERATING PROCEDURES EVALUATION The applicant did not propose any changes that affect the staffs operating procedures evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
10.0 ACCEPTANCE TESTS AND MAINTENANCE PROGRAM EVALUATION The applicant did not propose any changes that affect the staffs acceptance tests and maintenance program evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
11.0 RADIATION PROTECTION EVALUATION The applicant did not propose any changes that affect the staffs radiation protection evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
12.0 ACCIDENT ANALYSIS EVALUATION The applicant requested no changes to the principal design criteria related to the SSCs important to safety. For this reason, the staff finds the applicant complied with the relevant general criteria established in 10 CFR Part 72 and does not require an accident analysis evaluation of the principal design criteria.
13.0 TECHNICAL SPECIFICATIONS The applicant did not propose any changes to the HI-STORM 100 Cask System technical specifications. Therefore, the staff determined that a new evaluation was not required.
14.0 QUALITY ASSURANCE EVALUATION The applicant did not propose any changes that affect the staffs quality assurance program evaluation provided in previous safety evaluations for CoC No. 1014, Renewed Initial Certificate and Amendment Nos. 1 through 15. Therefore, the staff determined that a new evaluation was not required.
15.0 CONCLUSION
S The staff has performed a comprehensive review of the amendment application, during which the following requested changes to the HI-STORM 100 Cask System were considered:
Update the system description in the CoC to clearly indicate that only the portions of MPC components that come into contact with the pool water need to be made of stainless steel or aluminum.
Based on the statements and representations provided by the applicant in its amendment application, the staff concludes that the changes described above to the HI-STORM 100 Cask System do not affect the ability of the cask system to meet the requirements of 10 CFR Part 72.
Amendment No. 17 to renewed CoC No. 1014 for the HI-STORM 100 Cask System should be approved.
Issued with Renewed Certificate of Compliance No. 1014, Amendment No. 17 On December 5, 2023.
References Holtec. 2021a. Holtec International, Submittal of RAI Clarification Responses on HI-STORM 100 License RenewalUpdated Attachment. Holtec Letter 5014923. April 23, 2021.
Agencywide Documents Access and Management System (ADAMS) Accession No. ML21113A201.
Holtec. 2021b. HI-STORM 100 Multipurpose Canister Storage System Amendment 17 Request. Holtec Letter 5014929. July 30, 2021. ADAMS Accession No. ML21211A603.
NRC. 2019. Managing Aging Processes in Storage (MAPS) Report. NUREG-2214. Final Report. July 2019. ADAMS Accession No. ML19214A111.
NRC. 2020. Standard Review Plan for Spent Fuel Dry Storage Systems and Facilities.
NUREG-2215. Final Report. April 2020. ADAMS Accession No. ML20121A190.
NRC. 2023. Renewal of Initial Certificate and Amendment Nos. 1 - 15 of the Certificate of Compliance No. 1014 for the HI-STORM 100 Cask System. June 2023. ADAMS Accession No. ML23068A384.