ML21063A212

From kanterella
Jump to navigation Jump to search

Letter: CoC 1025 RAI Transmittal
ML21063A212
Person / Time
Site: 07201025
Issue date: 03/23/2021
From: Christopher Markley
Storage and Transportation Licensing Branch
To: Fowler W
NAC International
Markley C
Shared Package
ML21063A211 List:
References
CAC 001028, CoC No. 1025, EPID L-2019-RNW-0029
Download: ML21063A212 (3)


Text

W. Fowler 2

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 23, 2021 Mr. Wren Fowler Director, Licensing, Engineering NAC International 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE TECHNICAL REVIEW OF THE APPLICATION FOR RENEWAL OF THE CERTIFICATE OF COMPLIANCE NO. 1025 (CAC/EPID NOS. 001028/L-2019-RNW-0029)

Dear Mr. Fowler:

By letter dated December 18, 2019, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19357A178), NAC International (NAC) submitted an application for renewal of Certificate of Compliance (CoC) No. 1025 for the NAC-Multi-Purpose Canister (NAC-MPC). In my letter dated, May 4, 2020, I acknowledged acceptance of your application for a detailed technical review and provided a proposed schedule for the U.S. Nuclear Regulatory Commission (NRC) review (ADAMS Accession No. ML20125A133).

In connection with the NRC staffs technical review, we need the information identified in the enclosed request for additional information (RAI). Discussion of the RAIs and RAI response date occurred on February 18, 2021 (ML21060B437). Per that discussion we request that you provide this information by June 1, 2021. Inform us at your earliest convenience, but no later than May 14, 2021, if you are not able to provide the information by that date. To assist us in rescheduling your review, you should include a new proposed submittal date and the reasons for the delay. Also, as noted in the proprietary determination letter (ADAMS Accession No. ML20064E622), we agreed it would be beneficial to provide a high-level summary of the findings and conclusions made in Enclosure 6, Appendix E 30013-R-01, Maine Yankee NAC-UMS System Pre-Application Inspection Report, Rev. 0. This summary can be provided in the next update or supplement to the CoC renewal application.

Please reference Docket No. 72-1025 and CAC/EPID Nos. 001028/L-2019-RNW-0029 in future correspondence related to this request. The NRC staff is available to clarify these questions, and if necessary, to meet and discuss your proposed responses.

W. Fowler 2

If you have any questions regarding this matter, please contact me at (301) 415-6293 or at Christopher.Markley@nrc.gov.

Sincerely, Christopher T. Markley, Systems Performance Analyst Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1025 CAC No. 001028 EPID No. L-2019-RNW-0029

Enclosure:

As stated

W. Fowler 3

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE TECHNICAL REVIEW OF THE APPLICATION FOR RENEWAL OF THE CERTIFICATE OF COMPLIANCE NO. 1025 (CAC/EPID NOS. 001028/L-2019-RNW-0029)

DOCUMENT DATE: March 23, 2021 DISTRIBUTION:

NMSS/DSFM r/f RidsOpaMail Resource KBanovac, NMSS ADAMS Package Accession No.: ML21063A211

  • concurrence via email OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NAME CMarkley TAhn*

WWheatley*

DATE 2/18/2021 2/4/2021 3/5/2021 OFFICE NMSS/DFM NMSS/DFM NAME TBoyce*

JMcKirgan*

DATE 2/4/2021 3/12/2021 OFFICIAL RECORD COPY