30002-DI-07 PAGE 1 OF 2 REVISION 0 NAC PROPRIETARY INFORMATION DUKE ENERGY MCGUIRE NUCLEAR STATION DESIGN INPUT 30002-DI-07 REVISION 0 DUKE ENERGY - MCGUIRE NUCLEAR STATION MEMO - CANISTER CONTENTS WEIGHT FOR MAG-TSC-418-099

SUMMARY

This document contains data for the McGuire Nuclear Station.

ATTACHMENT

1. Duke Energy - McGuire Nuclear Station Memorandum - Canister Contents Weight for MAG-TSC-418-099 2 Pages APPROVAL FOR USE Approved for Use 7-3-18 for Eric Shewbridge Date NAC-Duke Energy Project Manager R-238189

Page 1 of 1 Duke Energy Carolinas, Fuel Management & Design, Spent Fuel Management Date:

June 21, 2018 To:

Eric Shewbridge, NAC International From:

Steve Edwards, Manager Spent Fuel Management Steven.Edwards@duke-energy.com (704)-382-9284

Subject:

Canister Contents Weight for MAG-TSC-418-099 This memo is to document generation, review, and approval of canister contents weight for MAG-TSC-418-099. This is to support NAC analysis in resolution of helium backfill issues documented in Duke NCR 02211048.

The canister contents weight is conservatively calculated as 55,906 lbs (53,807 lbs for fuel assemblies and 2,098.4 lbs for nonfuel hardware). This is based on fuel assembly and component types identified in Reference 1 and maximum weights documented in Reference 2.

References:

1. Duke Energy Approved Fuel Selection Package for MAG-TSC-418-099.
2. Assembly Specifications for Fuel Qualification for Dry Storage Canisters at McGuire Nuclear Station, MCC-1553.12-00-0017, Revision 7, Duke Energy Corporation, May, 2018. (Revision 8 pending but does not impact weight calculation)

Prepared By: Matt Keene Senior Engineer, Spent Fuel Management Checked By: Chris Long Senior Engineer, Spent Fuel Management Approved By: Steve Edwards Manager, Spent Fuel Management MEK8842 (218842)

Digitally signed by MEK8842 (218842)

Date: 2018.06.21 12:33:55 -04'00' CGLon3 (271593)

Digitally signed by CGLon3 (271593)

Date: 2018.06.21 15:03:42 -04'00' i32494 (336709)

Digitally signed by i32494 (336709)

Date: 2018.06.21 15:06:37 -04'00' 30002-DI-07 Page 2 of 2