Letter to B. Jenkins Request for Additional Information for the Technical Review of the Application for Renewal of the Trojan Independent Spent Fuel Storage Installation License No. SNM-2509 (CAC No. 001028)
ML19035A610
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 02/04/2019
From: Christopher Markley
Renewals and Materials Branch
To: Jenkins B
Portland General Electric Co
Markley C
Shared Package
ML19035A609 List:
References
CAC 001028, EPID L-2017-RNW-0011
Download: ML19035A610 (4)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 4, 2019 Mr. Bradley Y. Jenkins Vice President, Power Supply Generation Portland General Electric 121 SW Salmon Street Portland, OR 97204

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE TECHNICAL REVIEW OF THE APPLICATION FOR RENEWAL OF THE TROJAN INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE NO. SNM-2509 (CAC NO.

001028)

Dear Mr. Jenkins:

By letter dated March 23, 2017, Portland General Electric Company (PGE) submitted an application for renewal of License No. SNM-2509 for the Trojan Independent Spent Fuel Storage Installation (ISFSI) (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17086A039) for an additional 40 year period beyond the end of the current license term. The original 20 year ISFSI license expires on March 31, 2019. In my letter dated, May 31, 2017, I acknowledged acceptance of your application for a detailed technical review and provided a proposed schedule for the U.S. Nuclear Regulatory Commission (NRC) review (ADAMS Accession No. ML17144A197).

In connection with the NRC staffs technical review, we need the information identified in the enclosed request for additional information (RAI). Discussion of the RAI and RAI response date occurred on February 4, 2019. Per that discussion we request that you provide this information by February 22, 2019.

Please reference Docket No. 72-17 and CAC/EPID No. 001028/L-2017-RNW-0011 in future correspondence related to this request. The NRC staff is available to clarify these questions, and if necessary, to meet and discuss your proposed responses.

B. Jenkins 2 If you have any questions regarding this matter, please contact me at (301) 415-6293 or at Christopher.Markley@nrc.gov.

Sincerely,

/RA/

Christopher T. Markley, Systems Performance Analyst Renewals and Materials Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-17 License No. SNM-2509 CAC No. 001028 EPID No. L-2017-RNW-0011

Enclosure:

RAI cc: Trojan Service List

Trojan ISFSI Renewal Service List cc:

Chairman of the Board of County Commissioners Columbia County St. Helens, OR 97501 Mr. Todd Cornett, Siting Division Administrator Oregon Department of Energy 550 Capitol Street NE, 1st Floor Salem, OR 97301 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Mark E. Tursa PGE Trojan ISFSI Manager 71760 Columbia River Hwy Rainier, OR 97048 Lloyd K. Marbet, Executive Director Oregon Conservancy Foundation 19140 SE Bakers Ferry Road Boring, OR 97009 Jay Dudley, Esq.

Vice President, General Counsel and Corporate Compliance Officer Portland General Electric 121 S.W. Salmon Street Portland, OR 97204 Ken Niles Assistant Director for Nuclear Safety Oregon Department of Energy 625 Marion Street NE Salem, OR 97301

ML19035A609 OFFICE NMSS/DSFM NMSS/DSFM NRR/DLP NMSS/DSFM WWheatley ABowers MRahimi NAME CMarkley By e-mail By e-mail By e-mail DATE 1/28/19 1/30/19 1/30/19 2/4/19