{{#Wiki_filter: | {{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 17, 2018 Ms. Kimberly Manzione Licensing Manager Holtec International Holtec Technology Campus 1 Holtec Boulevard Camden, NJ 08104 | ||
Ms. Kimberly Manzione Licensing Manager Holtec International Holtec Technology Campus 1 Holtec Boulevard Camden, NJ 08104 | |||
==SUBJECT:== | ==SUBJECT:== | ||
APPLICATION FOR HOLTEC INTERNATIONAL HI-STORM UMAX | APPLICATION FOR HOLTEC INTERNATIONAL HI-STORM UMAX MULTIPURPOSE CANISTER STORAGE SYSTEM LICENSE AMENDMENT REQUEST NO. 3 TO CERTIFICATE OF COMPLIANCE NO. 1040 - | ||
ACCEPTED FOR REVIEW | ACCEPTED FOR REVIEW | ||
==Dear Ms. Manzione:== | ==Dear Ms. Manzione:== | ||
By letter dated August 30, 2016 (Agencywide Documents Access Management System, (ADAMS) Accession Number, ML16250A393), Holtec International (Holtec) submitted an application for amendment to the certificate of compliance (CoC) for the HI-STORM UMAX multipurpose canister storage system requesting to accommodate non-Holtec canisters (e.g., NUHOMS 24PT1-DSC). The calculation packages that support the amendment request were submitted under a separate letter dated September 9, 2016 (ML16258A213). By letter dated November 2, 2016 (ML16313A170), Holtec supplemented the amendment request. As a result of | By {{letter dated|date=August 30, 2016|text=letter dated August 30, 2016}} (Agencywide Documents Access Management System, (ADAMS) Accession Number, ML16250A393), Holtec International (Holtec) submitted an application for amendment to the certificate of compliance (CoC) for the HI-STORM UMAX multipurpose canister storage system requesting to accommodate non-Holtec canisters (e.g., | ||
NUHOMS 24PT1-DSC). The calculation packages that support the amendment request were submitted under a separate {{letter dated|date=September 9, 2016|text=letter dated September 9, 2016}} (ML16258A213). By {{letter dated|date=November 2, 2016|text=letter dated November 2, 2016}} (ML16313A170), Holtec supplemented the amendment request. As a result of staffs formal request for supplemental information, {{letter dated|date=January 23, 2017|text=letter dated January 23, 2017}} (ML17023A058), and the public meeting held on June 7, 2017 (meeting summary, {{letter dated|date=July 7, 2017|text=letter dated July 7, 2017}}, ML17188A274), Holtec again supplemented the application by letters dated, March 3, 2017 (ML17067A060), June 29, 2017 (ML17187A176), and August 4, 2017 (ML17229B196). Staff performed an acceptance review of Holtecs application to determine if the application contains sufficient technical information in scope and depth to allow the staff to complete the detailed technical review. | |||
This letter acknowledges acceptance of | This letter acknowledges acceptance of Holtecs application. The application appears to contain the information needed to start our technical review. However, we have identified an early request for additional information (RAI). The RAI is provided as an enclosure to this letter. We expect a response to the administrative RAI without delay and response to the thermal RAI within forty-five (45) days from the date of this letter. If Holtec is unable to meet the due date, please inform us in writing at your earliest convenience, but no later than a week prior to the due date. You should also include a new proposed submittal date and the reasons for the delay to assist us in re-scheduling your review. | ||
We have established a schedule for the review. The schedule allows for staff to issue a comprehensive RAI package by May 15, 2018. The schedule allows for staff to issue the CoC/staff evaluation report in October 2018, based on the applicant responding to RAIs by July 29, 2018. If no additional RAI is needed, and based on the staffs evaluation, the | |||
approval may be issued at approximately that time. In general, no additional changes to the application should be submitted except for changes resulting from your response to a RAI. | |||
If you have any questions regarding this matter, please contact me at (301) 415-7465. | If you have any questions regarding this matter, please contact me at (301) 415-7465. | ||
Sincerely, | Sincerely, | ||
/RA J. Nguyen Acting for/ | |||
Pamela Longmire, Ph.D. | |||
Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1040 CAC No.: 001028 EPID: L-2017-LLA-0033 | |||
==Enclosure:== | |||
Request for Additional Information | |||
G:/SFST/HI-STORM UMAX/Amendment 3/Letters to applicant/Acceptance Letter.docx G:/SFST/HI-STORM UMAX/Amendment 3/Letters to applicant/RAI-staggered(1).docx ADAMS Package No.: ML18018A017 C = COVER | APPLICATION FOR HOLTEC INTERNATIONAL HI-STORM UMAX MULTIPURPOSE CANISTER STORAGE SYSTEM LICENSE AMENDMENT REQUEST NO. 3 TO CERTIFICATE OF COMPLIANCE NO. 1040 - ACCEPTED FOR REVIEW, DOCUMENT DATE: JANUARY 17, 2018 DISTRIBUTION: | ||
}} | SFM R/F JTapp ARigato EGoldfeiz CBajwa JSolis JSmith DTarantino YDiaz-Sanabria PSilva TTate MRahimi G:/SFST/HI-STORM UMAX/Amendment 3/Letters to applicant/Acceptance Letter.docx G:/SFST/HI-STORM UMAX/Amendment 3/Letters to applicant/RAI-staggered(1).docx ADAMS Package No.: ML18018A017 C = COVER E = COVER & ENCLOSURE N = NO COPY OFC NMSS/DSFM NMSS/DSFM NMSS/DSFM NAME PLongmire WWheatley MRahimi DATE 12/21/2017 1/11/2018 1/17/2018 OFFICIAL RECORD COPY}} | ||
Latest revision as of 05:25, 7 January 2025
| ML18018A018 | |
| Person / Time | |
|---|---|
| Site: | HI-STORM 100 |
| Issue date: | 01/17/2018 |
| From: | Pamela Longmire Spent Fuel Licensing Branch |
| To: | Manzione K Holtec |
| Longmire P | |
| Shared Package | |
| ML18018A017 | List: |
| References | |
| CAC 001028, EPID L-2017-LLA-0033 | |
| Download: ML18018A018 (3) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 17, 2018 Ms. Kimberly Manzione Licensing Manager Holtec International Holtec Technology Campus 1 Holtec Boulevard Camden, NJ 08104
SUBJECT:
APPLICATION FOR HOLTEC INTERNATIONAL HI-STORM UMAX MULTIPURPOSE CANISTER STORAGE SYSTEM LICENSE AMENDMENT REQUEST NO. 3 TO CERTIFICATE OF COMPLIANCE NO. 1040 -
ACCEPTED FOR REVIEW
Dear Ms. Manzione:
By letter dated August 30, 2016 (Agencywide Documents Access Management System, (ADAMS) Accession Number, ML16250A393), Holtec International (Holtec) submitted an application for amendment to the certificate of compliance (CoC) for the HI-STORM UMAX multipurpose canister storage system requesting to accommodate non-Holtec canisters (e.g.,
NUHOMS 24PT1-DSC). The calculation packages that support the amendment request were submitted under a separate letter dated September 9, 2016 (ML16258A213). By letter dated November 2, 2016 (ML16313A170), Holtec supplemented the amendment request. As a result of staffs formal request for supplemental information, letter dated January 23, 2017 (ML17023A058), and the public meeting held on June 7, 2017 (meeting summary, letter dated July 7, 2017, ML17188A274), Holtec again supplemented the application by letters dated, March 3, 2017 (ML17067A060), June 29, 2017 (ML17187A176), and August 4, 2017 (ML17229B196). Staff performed an acceptance review of Holtecs application to determine if the application contains sufficient technical information in scope and depth to allow the staff to complete the detailed technical review.
This letter acknowledges acceptance of Holtecs application. The application appears to contain the information needed to start our technical review. However, we have identified an early request for additional information (RAI). The RAI is provided as an enclosure to this letter. We expect a response to the administrative RAI without delay and response to the thermal RAI within forty-five (45) days from the date of this letter. If Holtec is unable to meet the due date, please inform us in writing at your earliest convenience, but no later than a week prior to the due date. You should also include a new proposed submittal date and the reasons for the delay to assist us in re-scheduling your review.
We have established a schedule for the review. The schedule allows for staff to issue a comprehensive RAI package by May 15, 2018. The schedule allows for staff to issue the CoC/staff evaluation report in October 2018, based on the applicant responding to RAIs by July 29, 2018. If no additional RAI is needed, and based on the staffs evaluation, the
approval may be issued at approximately that time. In general, no additional changes to the application should be submitted except for changes resulting from your response to a RAI.
If you have any questions regarding this matter, please contact me at (301) 415-7465.
Sincerely,
/RA J. Nguyen Acting for/
Pamela Longmire, Ph.D.
Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1040 CAC No.: 001028 EPID: L-2017-LLA-0033
Enclosure:
Request for Additional Information
APPLICATION FOR HOLTEC INTERNATIONAL HI-STORM UMAX MULTIPURPOSE CANISTER STORAGE SYSTEM LICENSE AMENDMENT REQUEST NO. 3 TO CERTIFICATE OF COMPLIANCE NO. 1040 - ACCEPTED FOR REVIEW, DOCUMENT DATE: JANUARY 17, 2018 DISTRIBUTION:
SFM R/F JTapp ARigato EGoldfeiz CBajwa JSolis JSmith DTarantino YDiaz-Sanabria PSilva TTate MRahimi G:/SFST/HI-STORM UMAX/Amendment 3/Letters to applicant/Acceptance Letter.docx G:/SFST/HI-STORM UMAX/Amendment 3/Letters to applicant/RAI-staggered(1).docx ADAMS Package No.: ML18018A017 C = COVER E = COVER & ENCLOSURE N = NO COPY OFC NMSS/DSFM NMSS/DSFM NMSS/DSFM NAME PLongmire WWheatley MRahimi DATE 12/21/2017 1/11/2018 1/17/2018 OFFICIAL RECORD COPY