Letter Sequence Other |
|---|
CAC:001028, ECCS Response Time Testing (Approved, Closed) EPID:L-2021-LLA-0053, Attachment 2: Updated Summary of Proposed Changes (non-proprietary) (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML17318A087, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI 2018-01-10
[Table View] |
Text
Page 1 of 3 Holtec Responses to Action Items listed in Meeting Minutes [1] on HI-STORM FW Amendment 7 RAI 3-10 Response Clarification Call Docket No.72-1032 Holtec International HI-STORM FW Multipurpose Canister Storage System Certificate of Compliance No. 1032 Amendment No. 7 Action 1 Holtec will provide supplemental information on the analysis at higher temperature that bounds the fuel basket, show its correlation to ultimate strength, and the safety margin using 90%
ultimate strength.
Holtec Response:
Holtec has revised Position Paper DS-331 to include additional results for Metamic-HT fuel baskets at higher temperatures (up to 400°C) that bound the thermal analysis results in Chapter 4 of the HI-STORM FW FSAR. The maximum stress in the Metamic-HT basket panels remains below 90% of the materials ultimate strength for all analyzed temperatures (from 275°C to 400°C). A copy of Position Paper DS-331 Rev. 3 is attached.
Action 2 Holtec will provide additional information related to Metamic-HT material property.
Holtec Response:
Holtecs Metamic-HT was first used in the HI-STAR 180 system. A Metamic-HT Qualification Sourcebook [2] was created to support the approval of this material for use in the HI-STAR 180 system. The Summary of Changes for Revision 1 (June 2009) and Revision 2 (August 2009) of the Metamic-HT Sourcebook states that the revisions were made as the result of RAIs and technical interactions with the NRC Staff under Docket No. 71-9325 (HI-STAR 180).
Per the Metamic-HT Sourcebook, To determine its suitability in dry storage applications, Metamic-HTs properties listed in Table 1.2 have been quantified by a testing program that emulates the qualification regimen of an ASTM material. Using the test data, the minimum values of the mechanical and thermo-physical properties are determined in the test program.
Values of properties that are equal to or less than the minimum values are set down as Minimum Guaranteed Values (MGV). Holtecs responses to the HI-STAR 180 Initial Application RAIs [3] explain that the Minimum Guaranteed Value (MGV) is required to be less than the Minimum Measured Value of the property from the entire batch of data in the database. For structural qualification of fuel basket Holtec deploys an approach that is more conservative than the ASME Code. The approach is based on limiting the maximum panel displacement under design basis events. This approach is evaluated in Holtec Position Paper DS-331. Further information can be found in Holtecs responses to the Materials RAIs [3]
Holtec Letter 5018108 Attachment 1
Page 2 of 3 The NRCs SER for 71-9325 CoC Revision 0 [4] describes the basis for approval of Metamic-HT for use in the HI-STAR 180 system.
From 180 SER Section 2.9: The applicant provided data to quantify the performance and characteristics of Metamic-HT in a manner somewhat emulating that of an ASTM/ASME material, but with several deviations from normal ASME Code practice (which the staff uses as a benchmark). One deviation is the establishment of the "minimum guaranteed value" (MGV) for various properties. The MGV values adopted by the applicant differ from the "stress allowable" used by the ASME Code. The Code "stress allowable" is directly used for stress-based design calculations. The applicant's MGV data is primarily used as the Metamic-HT material production QA/QC acceptance criteria. Consequently, a direct comparison of "stress allowable" with MGV's is not valid.
Furthermore, The applicant provided Revision No.2 to the Qualification Sourcebook incorporating major changes largely prompted by the staff's review. In particular, additional coupons tested were added to the respective data tables to broaden the data base for all properties; the coupons data includes separate data sets of up to 30 coupons each for as-extruded as well as thermally aged and irradiated coupons at different temperatures; the use of the statistical approach (mean minus two sigma) has been discontinued in favor of a more conservative approach. Now, the MGV is required to be less than the "Minimum Measured Value" of the property from the entire batch of data in the database to eliminate concerns of data scatter and lot-to-Iot variability; design criteria for structural reliance of Metamic-HT in fuel basket applications have been added to the Sourcebook and a justification provided for the dimensionless maximum lateral deflection in fuel baskets utilizing Metamic-HT panels in lieu of ASME based code stress limits; the production sampling plan has been expanded to establish the link between in-production testing and the required level of reliability of the material's property; Metamic-HT was eventually also approved for use in the HI-STORM FW system, where it was used in a dry storage system for the first time. The NRCs SER for 72-1032 Amendment 0 [5]
describes the basis for approval of Metamic-HT for use in the HI-STORM FW system in the Chapter 8 Materials Evaluation.
From FW SER Section 8.1: Since Metamic HT is a new structural material, a comprehensive test program was necessary to fully determine its physical properties and characteristics. The testing program emulated that typically employed to qualify an American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code structural material. Holtec provided extensive data from their testing program for staff review. The data and analyses were documented in the Holtec comprehensive proprietary report; Metamic HT Qualification Sourcebook. Since this document and data are proprietary, the staff summarizes the testing program and findings in lieu of excerpting detailed technical discussion from the applicants documents.
From FW SER Section 8.1.1: Using the guidance of ASME Section II, Appendix 5, Holtec determined mechanical properties (as listed previously) at room temperature and also at several temperatures ranging from minus 40 degrees C to 500 degrees C. The test data was analyzed using statistical methods and minimum, average, and mean values of the various properties were determined. Additionally, a design value for the various properties was established which is called the Minimum Guaranteed Value (MGV). The MGV is a numerical value (for any given Holtec Letter 5018108 Attachment 1
Page 3 of 3 property) which was chosen to be below the lowest measured value from the test data. The MGV is then demonstrated (guaranteed) to be exceeded for every manufactured lot of Metamic HT through lot testing. Any lot which fails to meet one (or more) MGV values is discarded. Lot testing sample size is controlled by a statistical sampling approach. If any lot of material fails to meet any one of the various MGVs, then an enhanced sampling plan is invoked for subsequent production lots.
The FW SER Section 8.1.10: Conclusions used the same language as was used in the HI-STAR 180 SER: The applicant has provided data to quantify the performance and characteristics of Metamic HT in a manner somewhat emulating that of an ASTM/ASME material, but with several deviations from normal ASME Code practice (the staff uses the ASME Code as a benchmark).
One deviation is the establishment of the MGV for various properties. The MGV values adopted by the applicant differ from the stress allowable used by the ASME Code. The Code stress allowable is directly used for stress-based design calculations. The applicants MGV data is primarily used as the Metamic HT material production QA/QC acceptance criteria.
The HI-STORM FW FSAR [6] lists the applicable Metamic-HT MGVs in Table 1.2.8a and the qualification tests for the material are discussed in Sections 10.1.3 and 10.1.6.2 and Tables 10.1.6 through 10.1.8. The enhanced sampling plan mentioned in the SER quote above is described in the notes to Table 10.1.7. All Metamic-HT used in all HI-STORM FW canisters, both past and present, has been subjected to these tests to provide additional assurance that the properties continue to meet the required values.
Metamic-HT was never presented as an ASME material. However, the data presented in the Metamic-HT Sourcebook, unchanged from previous NRC reviews, and the continued use of approved qualification testing provided, and should continue to provide, the same confidence level for the use of Metamic-HT in Holtec equipment as exists for any ASME qualified material, and for all prior approvals of the HI-STORM FW.
References:
[1] Clarification Call with Holtec on HI-STORM FW Amendment 7 Request for Additional Information (RAI) 3-10 Conversation Record between Holtec and NRC associates dated August 3, 2023. ADAMS Accession No. ML23216A217.
[2] HI-2084122 Revision 14 (latest revision), Metamic-HT Qualification Sourcebook
[3] Transmittal of Response to Additional Information on HI-STAR 180 Transport Cask letter from T. Morin (Holtec) to P. Saverot (NRC) dated July 13, 2009. ADAMS Accession No. ML091970336.
[4] NRCs SER for HI-STORM 180 CoC No. 71-9325 Revision 0. ADAMS Accession No. ML092890297
[5] NRCs SER for HI-STORM FW CoC No. 72-1032 Amendment 0. ADAMS Accession No. ML111950325.
[6] HI-2114830, Final Safety Analysis Report for HI-STORM FW MPC Dry Storage System, Latest Revision Holtec Letter 5018108 Attachment 1