Letter Sequence Approval |
|---|
CAC:001028, ECCS Response Time Testing (Approved, Closed) EPID:L-2022-LLA-0228, Independent Spent Fuel Storage Installation - Annual Radiological Environmental Monitoring Report for 2021 (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML17318A087, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI 2018-01-10
[Table View] |
Text
Humboldt Bay ISFSI Amendment 5 Technical Specification Page Changes Remove Page Table of Contents 3.1-2 3.1-6 4.0-2 5.0-1 5.0-2 Insert Revised Page Table of Contents 3.1-2 3.1-6 4.0-2 5.0-1 5.0-2
TABLE OF CONTENTS 1.0 USE AND APPLICATION..........................................................................................................1.1-1 1.1 Definitions........................................................................................................................1.1-1 1.2 Logical Connectors..........................................................................................................1.2-1 1.3 Completion Times............................................................................................................1.3-1 1.4 Frequency........................................................................................................................1.4-1 2.0 APPROVED CONTENTS..........................................................................................................2.0-1 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY.........................................3.0-1 3.0 SURVEILLANCE REQUIREMENT (SR) APPLICABILITY........................................................3.0-2 3.1 Spent Fuel Storage Cask (SFSC) Integrity......................................................................3.1-1 3.1.1 Multi-Purpose Canister (MPC-HB)...................................................................................3.1-1 3.1.2 Overpack Heat Removal System.....................................................................................3.1-3 3.1.3 Deleted.............................................................................................................................3.1-6 4.0 DESIGN FEATURES.................................................................................................................4.0-1 4.1 Design Features Significant to Safety..............................................................................4.0-1 4.1.1 Criticality Control.............................................................................................................4.0-1 4.2 Codes and Standards......................................................................................................4.0-1 4.2.1 Alternatives to Design Codes, Standards, and Criteria....................................................4.0-1 4.3 Cask Handling..................................................................................................................4.0-2 4.3.1 Cask Transporter.............................................................................................................4.0-2 4.3.2 Storage Capacity.............................................................................................................4.0-2 4.3.3 SFSC Load Handling Equipment.....................................................................................4.0-2 5.0 ADMINISTRATIVE CONTROLS................................................................................................5.0-1 5.1 Administrative Programs..................................................................................................5.0-1 5.1.1 Technical Specifications (TS) Bases Control Program....................................................5.0-1 5.1.2 Radioactive Effluent Control Program..............................................................................5.0-1 5.1.3 Deleted.............................................................................................................................5.0-1 5.1.4 ISFSI Operations Program...............................................................................................5.0-2 5.1.5 Cask Transportation Evaluation Program........................................................................5.0-2 5.1.6 Deleted.............................................................................................................................5.0-2 5.1.7 Quality Assurance Program Changes..............................................................................5.0-2 HUMBOLDT BAY ISFSI T of C Renewed License Amendment 5
MPC-HB 3.1.1 ACTIONS (continued)
CONDITION REQUIRED ACTION COMPLETION TIME C.
MPC-HB helium leak rate limit for vent and drain port cover plate welds not met.
C.1 Perform an engineering evaluation to determine the impact of increased helium leak rate on heat removal capacity.
AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> C.2 Develop and initiate corrective actions necessary to return the MPC-HB to an analyzed condition.
7 days SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.1.1.1 Verify MPC-HB cavity vacuum drying pressure is 3 torr for 30 min.
OR Once, prior to TRANSPORT OPERATIONS.
While recirculating helium through the MPC-HB cavity, verify that the gas temperature exiting the demoisturizer is 21F for 30 min or the dew point of the gas exiting the MPC is < 22.9F for 30 min.
SR 3.1.1.2 Verify MPC-HB helium backfill pressure is 45.2 psig and 48.8 psig at a reference temperature of 70F.
Once, prior to TRANSPORT OPERATIONS.
SR 3.1.1.3 Verify that the total helium leak rate through the MPC-HB vent and drain port cover plate welds is 1.0E-7 atm-cc/sec (He).
Once, prior to TRANSPORT OPERATIONS.
HUMBOLDT BAY ISFSI 3.0 Renewed License Amendment 5 3.1-2
3.1 SFSC INTEGRITY 3.1.3 Deleted HUMBOLDT BAY ISFSI 3.0 Renewed License Amendment 5 3.1-6
Design Features 4.0 4.0 DESIGN FEATURES (continued) 4.3 Cask Handling 4.3.1 Cask Transporter A cask transporter is used to transport the SFSC. The requirements for the cask transporter are as follows:
a.
TRANSPORT OPERATIONS shall be conducted using the cask transporter.
b.
The cask transporter fuel tank shall not contain 50 gallons of diesel fuel at any time.
c.
The cask transporter shall be designed, fabricated, inspected, maintained, operated, and tested in accordance with the applicable guidelines of NUREG-0612.
d.
The cask transporter lifting towers shall have redundant drop protection features.
4.3.2 Storage Capacity The Humboldt Bay ISFSI can accommodate up to 400 spent fuel assemblies. The ISFSI storage capacity can accommodate up to six SFSCs.
4.3.3 SFSC Load Handling Equipment Lifting of a SFSC shall be performed with load handling equipment that is designed, fabricated, inspected, maintained, operated and tested in accordance with the applicable guidelines of NUREG-0612, "Control of Heavy Loads at Nuclear Power Plants.
HUMBOLDT BAY ISFSI 4.0 Renewed License Amendment 5 4.0-2
Administrative Controls 5.0 5.0 ADMINISTRATIVE CONTROLS 5.1 Administrative Programs The following programs shall be established, implemented, and maintained:
5.1.1 Technical Specifications (TS) Bases Control Program This program provides a means for processing changes to the Bases of these TS.
a.
Changes to the TS Bases shall be made under appropriate administrative controls and reviews.
b.
Changes to the TS Bases may be made without prior NRC approval in accordance with the criteria in 10 CFR 72.48.
c.
The TS Bases Control Program shall contain provisions to ensure that the TS Bases are maintained consistent with the Humboldt Bay ISFSI SAR.
d.
Proposed changes that do not meet the criteria of 5.1.1.b above shall be reviewed and approved by the NRC prior to implementation. Changes to the TS Bases implemented without prior NRC approval shall be provided to the NRC on a frequency consistent with 10 CFR 72.48 (d) (2).
5.1.2 Radioactive Effluent Control Program a.
This program is established and maintained to implement the requirements of 10 CFR 72.44 (d) or 72.126, as appropriate. There are no radioactive gaseous or liquid effluents released from the Humboldt Bay Independent Spent Fuel Storage Installation (ISFSI) during operation. Therefore, a radioactive effluent monitoring system is not required, routine monitoring for effluents is not performed, and the licensee is exempted from the reporting requirements under 10 CFR 72.44(d)(3).
b.
Deleted 5.1.3 Deleted (continued)
HUMBOLDT BAY ISFSI 5.0 Renewed License Amendment 5 5.0-1
Administrative Controls 5.0 5.0 ADMINISTRATIVE CONTROLS (continued) 5.1.4 ISFSI Operations Program This program will implement the Humboldt Bay ISFSI SAR requirements for ISFSI operations. It will include criteria to be verified and controlled:
a.
SFSC cask storage location.
b.
Design features listed in Section 4.0 and design basis ISFSI parameters consistent with the Humboldt Bay ISFSI SAR analysis.
5.1.5 Cask Transportation Evaluation Program This program will evaluate and control the transportation of loaded SFSCs. Included in this program will be pre-transport evaluation and control during transportation of the following:
Transportation route road surface conditions.
Onsite hazards along the transportation route.
Security, including control of the 100 meter boundary.
Transporter control functions and operability.
Offsite marine hazards from barge transport.
Severe weather.
5.1.6 Deleted 5.1.7 Quality Assurance Program Changes a.
Changes to the Quality Assurance Program shall be reviewed and approved in accordance with administrative procedures.
b.
Changes may be made to the Quality Assurance Program without prior NRC approval provided the changes do not:
Reduce the commitments in the quality assurance program previously approved by the NRC.
Involve a change to the Humboldt Bay ISFSI License or Technical Specifications.
c.
Changes made to the Quality Assurance Program without prior NRC approval shall be submitted to the NRC consistent with the frequency in 10 CFR 72.70(c)(6).
d.
Proposed changes which do not meet the criteria in 5.1.7.b shall be approved by the NRC prior to implementation.
HUMBOLDT BAY ISFSI 5.0 Renewed License Amendment 5 5.0-2
ML22214A115; ML22214A118 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/CTCFB OEDO NAME DHabib WWheatley JSolis ARivera-Varona DATE Aug 8, 2022 Aug 10, 2022 Aug 15, 2022 Aug 17, 2022 OFFICE NMSS/DFM/CTCFB OGC/GCHA/AGCOR
/NLO*
NMSS/DFM/STLB NAME DMarcano JMcManus YDiaz-Sanabria DATE Aug 17, 2022 Oct 7, 2022 Oct 11, 2022