3.4 Tables Certificate of Compliance No. 1032 Amendment No. 75 Appendix A 3.4-1 Table 3-1 MPC Cavity Drying Limits Fuel Burnup (MWD/MTU)

MPC Type MPC Heat Load (kW)

Method of Moisture Removal (Notes 1 and 2)

All Assemblies 45,000 MPC-37 29 (Table 2.3-9A of Appendix B or pattern developed in accordance with Table 2.3-9B of Appendix B) 44.09 (Pattern A in Tables 2.3-1A, B, C of Appendix B) 45.00 (Pattern B in Table 2.3-1A of Appendix B) 37.4 (Figures 2.3-1 through 2.3-3 of Appendix B) 39.95 (Figures 2.3-4 through 2.3-6 of Appendix B) 44.85 (Figures 2.3-7 through 2.3-9 of Appendix B)

VDS (Notes 3 and 4) or FHD (Note 4)

MPC-32ML 44.16 (Pattern A in Table 2.3-5 of Appendix B)

MPC-37P 44.09 (Pattern A in Tables 2.3-1A of Appendix B) 45.00 (Pattern B in Table 2.3-1A of Appendix B) 45.00 (Table 2.3-7A of Appendix B)

MPC-44 28 (Table 2.3-13 of Appendix B) 44 (Table 2.3-8A of Appendix B)

MPC-89 29 (Table 2.3-10A of Appendix B or pattern developed in accordance with Table 2.3-10B of Appendix B) 46.36 (Table 2.3-2A of Appendix B) 46.2 (Figures 2.3-10 and 2.3-11 of Appendix B) 46.14 (Figures 2.3-12 and 2.3-13 of Appendix B)

Holtec Letter 5018094 Attachment 3

3.4 Tables Certificate of Compliance No. 1032 Amendment No. 75 Appendix A 3.4-2 Fuel Burnup (MWD/MTU)

MPC Type MPC Heat Load (kW)

Method of Moisture Removal (Notes 1 and 2)

One or more assemblies

> 45,000 MPC-37 29 (Table 2.3-9A of Appendix B or pattern developed in accordance with 2.3-9B of Appendix B) 29.6 (Table 2.3-3 of Appendix B)

VDS (Notes 3 and 4) or FHD (Note 4)

MPC-32ML 28.70 (Pattern B in Table 2.3-5 of Appendix B)

MPC-37P 33.3 (Table 2.3-7B of Appendix B)

MPC-44 28 (Table 2.3-13 of Appendix B) 30 (Table 2.3-8B of Appendix B)

MPC-89 29 (Table 2.3-10A of Appendix B or pattern developed in accordance with and 2.3-10B of Appendix B) 30.0 (Table 2.3-4 of Appendix B)

One or more assemblies

> 45,000 MPC-37 44.09 (Pattern A in Tables 2.3-1A, B, C of Appendix B) 45.00 (Pattern B in Table 2.3-1A of Appendix B) 37.4 (Figures 2.3-1 through 2.3-3 of Appendix B) 39.95 (Figures 2.3-4 through 2.3-6 of Appendix B) 44.85 (Figures 2.3-7 through 2.3-9 of Appendix B)

VDS (Notes 3, 4, and 5) or FHD (Note 4)

MPC-32ML 44.16 (Pattern A in Table 2.3-5 of Appendix B)

MPC-37P 44.09 (Pattern A in Tables 2.3-1A, B, C of Appendix B) 45.00 (Pattern B in Table 2.3-1A of Appendix B) 45.00 (Table 2.3-7A of Appendix B)

MPC-44 44 (Table 2.3-8A of Appendix B)

Holtec Letter 5018094 Attachment 3