3/22/2021 E-mail Request for Clarification of 2/26/2021 Rsi Response for GEH-Morris License Renewal Application
ML21085A859
Person / Time
Site: 07200001
(SNM-2500)
Issue date: 03/22/2021
From: Kristina Banovac
Storage and Transportation Licensing Branch
To: Mcfadden A
GE Hitachi Nuclear Energy
KLBanovac - NMSS/DFM/STL - 301.415.7116
References
CAC 001028, EPID L-2020-RNW-0024
Download: ML21085A859 (2)


Text

From:

Banovac, Kristina To:

McFadden, Anthony E (GE Power Portfolio); Murray, Scott P. (GE Power Portfolio)

Subject:

RE: RE: ACTION: request clarification of 2/26/21 RSI response for GEH-Morris license renewal application Date:

Monday, March 22, 2021 2:40:00 PM Hi Tony,

Thank you for your response and the clarification.

As the NRC staff reviews the license renewal application, the staff will refer to the current FSAR as the current design bases for the site. Therefore, please submit the current operating FSAR for the site (CSAR Revision 15, dated and implemented on February 23, 2021) on the docket. Please let me know if you have any questions about this request.

Thank you, Kris

From: McFadden, Anthony E (GE Power Portfolio) <anthony.mcfadden@ge.com>

Sent: Friday, March 19, 2021 10:18 AM To: Banovac, Kristina <Kristina.Banovac@nrc.gov>; Murray, Scott P. (GE Power Portfolio)

<Scott.Murray@ge.com>

Subject:

[External_Sender] RE: ACTION: request clarification of 2/26/21 RSI response for GEH-Morris license renewal application

Hi Kris,

Yes, Rev 15 dated Feb 23.2021 is the current operating FSAR for the site. There are no subsequent revisions in effect. As mentioned in the response, what we sent in June was a preview to Rev 15, but not the final. So, the June submittal did not include the steel expansion gate at that time, and was added for the formal implemented revision in February of this year.

r/

Tony

Tony McFadden Site Manager Morris Operation GE Hitachi Nuclear Energy O - (815) 942-5590 x174 C - (815) 953-8211

From: Banovac, Kristina <Kristina.Banovac@nrc.gov>

Sent: Friday, March 19, 2021 8:36 AM To: Murray, Scott P. (GE Power Portfolio) <Scott.Murray@ge.com>

Cc: McFadden, Anthony E (GE Power Portfolio) <anthony.mcfadden@ge.com>

Subject:

EXT: ACTION: request clarification of 2/26/21 RSI response for GEH-Morris license renewal application

Good morning Scott,

The NRC staff is currently reviewing GEHs 2/26/2021 response to the request for supplemental information (RSI) regarding the GEH-Morris license renewal application (ADAMS Accession No. ML21057A119). We are requesting one clarification regarding the RSI response, as follows.

GEHs response to RSI-1 notes: Effective Feb 23, 2021, CSAR Revision 15 has been implemented. CSAR, Rev 15 revision summaries for each Section, as well as a 10 CFR 72.48 evaluation for changes are submitted as Attachment 6.

of the RSI response notes that in Section 11.3.d of the CSAR Revision 15, steel expansion gate was added to the list of SSCs important to safety.

However, this change is not reflected in the CSAR Revision 15 that was provided with the license renewal application submittal in June 2020.

REQUEST: Could you please confirm that the CSAR Revision 15 is the current operating FSAR for the site and there is no subsequent revision in effect?

Please note that when you respond to this email, I will add your response to ADAMS as part of the docket for this licensing action.

Thank you, Kris

Kristina Banovac, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission 301-415-7116

Docket No. 72-01 License No. SNM-2500 CAC/EPID Nos. 001028/L-2020-RNW-0024 and 000993/L-2020-LNE-0004