NRC FORM 699 ** ~**"**,.'.<.

(03-2013) f ~~

u_s_ NUCLEAR REGULATORY COMMISSION

\\~Yli

.,.o CONVERSATION RECORD NAME OF PERSON(S) CONTACTED OR IN CONTACT WITH YOU Glenn Mathues E-MAIL ADDRESS glenn.mathues@orano.group ORGANIZATION TN Americas LLC LICENSE NUMBER($)

CoC I 042 EOS Amendment # I SUBJECT DOCKET NUMBER(S}

72-1042 CONTROL NUMBER($}

Clarification Call on RAJ # I response for CoC 1042 EOS Amendment #1.

SUMMARY

Participants:

DATE OF CONTACT 05/22/2019 TELEPHONE NUMBER (410) 910-6538 DATE OF SIGNATURE 05/23/2019 TYPE OF CONVERSATION DE-MAIL 0 TELEPHONE D

INCOMING 0 OUTGOING TN: Prakash Narayanan, Peter Shih, Yenkata Venigalla, Philippe Pham, Don Shaw, Hoi Yee Tom, Hui Liu, Laura Picard, Richard Migliore, Glenn Mathues, Karan Mauskar NRC: Christian Jacobs, John McKirgan, Veronica Wilson, JoAnn Ireland, Zhian Li, Jorge Solis, Ghani Zigh, Norma Garcia Santos, Yen Chen Continue on Page 2 ACTION REQUIRED (IF ANY)

TN to provide supplemental information to RAJ #I (date not yet specified). TN requesting follow-up clarification call for RAJ 6-7 (date to be determined).

Continue on Page 3 NAME OF PERSON DOCUMENTING CONVERSATION Christian Jacobs SIGNATURE J.

~I~,_,.,,_ __

NRC FORM 699 (03-2013)

Page 1 of 2

NRC FORM699 (03-2013)

U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD (continued)

SUMMARY

(Continued from page 1)

A clarification call requested by TN was held on May 22, 2019, with NRC staff for two purposes:

I) TN was seeking clarification on why the proposed supplemental response to RAJ 4-6 ( discussed during the May I, 20 l 9, clarification call - ADAMS Accession Number ML91923A113) would not adequately address RAI 4-6, and

2) TN proposed an approach to resolving RAJ 6-7.

RAJ 4-6: NRC staff provided clarification to TN as to why the proposed supplemental response to RAJ 4-6 would not adequately address the RAI. TN is revising their thermal model and will provide a supplemental response to adequately address NRC's concerns.

RAJ 6-7: TN provided a draft revised approach to resolving NRC concerns with regard to this RAJ. TN's draft approach can be found in ADAMS ML 19143A I I 2. NRC staff had several questions regarding the revised approach on the following topics:

- relationship between decay heat and source term

- instructions on how the users are to use the proposed table in the technical specifications (TS)

- how to treat outliers, instructions in the TS or Operating Procedures

- only using GWd units instead ofGWd/MTU units The applicant has agreed to provide supplemental information for RAJ 4-6, but has requested a follow-up clarification call on RAI 6-7 (to be scheduled).

Any correspondence or transmittal of supplemental information should include the following:

CAC: 001028 Docket: 72-1042 EPID: L-20 I 8-LLA-0043 NRC FORM 699 (03-2013)

Page 2 of 2