ML23103A420
Letter Sequence Approval | |
---|---|
CAC:001028, (Approved, Closed) EPID:L-2018-NEW-0001, International, Issuance of Materials License SNM-2516 for the HI-STORE Consolidated Interim Storage Facility ISFSI (Approved, Closed) | |
Initiation
Administration Questions
Answers Results
Other: L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML19150A559, ML19182A107, ML20002A442, ML20009D008, ML20010D564, ML20015A450, ML20015A451, ML20015A454, ML20028E845, ML20028E846, ML20049A082, ML20052E146, ML20052E154, ML20065N281, ML20071F156, ML20076D696, ML20099A180, ML20104C015, ML20104C018, ML20104C019, ML20105A135, ML20105A136, ML20105A137, ML20105A138, ML20105A139, ML20105A173, ML20111A240, ML20136A050, ML20136A051, ML20150A335, ML20150A421, ML20155K741, ML20155K743, ML20155K744, ML20161A088, ML20163A702, ML20163A703, ML20163A704, ML20181A211, ML20181A212, ML20192A328, ML20192A329, ML20212L768, ML20212L769, ML20261H420, ML20269A259, ML20279A577, ML20279A586, ML20289A493... further results | |
MONTHYEARML18088A0302018-03-28028 March 2018
[Table View]Letter to J. Tomlinson Holtec International'S Application for Specific ISFSI License for the HI-Store Consolidated Interim Storage Facility for Spent Nuclear Fuel-First Request for Additional Information, Part 1 (W/Enclosure) Project stage: RAI ML20052D9362018-07-0303 July 2018 Response to Nrg Request for Additional Information (RAI) Regarding NAC Magnastor Cask Loaded to Incorrect Helium Backfill Density Project stage: Request ML18267A2142018-08-29029 August 2018, 25 September 2018 Package: Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) Project stage: Request ML18257A2402018-09-13013 September 2018 Letter to K. Manzione Holtec International'S Application for Specific ISFSI License for the HI-STORE Consolidated Interim Storage Facility for Spent Nuclear Fuel - First Request for Additional Information, Part 2 (W/Enclosure 1) Project stage: RAI ML18267A2112018-09-25025 September 2018 Memorandum to A. Rivera-Varona Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) Project stage: Meeting ML18284A4272018-10-11011 October 2018 Letter to E. Mayer Holtec International'S Application for Specific ISFSI License for the HI-STORE Consolidated Interim Storage Facility for Spent Nuclear Fuel - First Request for Additional Information, Part 3 Project stage: RAI ML18320A1842018-11-16016 November 2018 Letter to J. Isakson Interim Storage Partners' License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrews County, Texas, Dkt No. 72-1050 - First RAI, Part 1 (W/Enclosure 1) Project stage: RAI ML19032A2302019-02-0404 February 2019 Summary of Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the Interim Storage Partner Consolidated Isfs Application for a Facility at Andrews County, Texas (W/Encl. 1&2) Project stage: RAI ML19065A0192019-03-0606 March 2019 Letter to J. Isakson Interim Storage Partners Llc'S License Application to Construct and Operate the WCS Consolidated Interim Storage Facility, Andrews County, Texas, Docket No. 72.1050 - First Request for RAI Part 2 (W/Enclosure 1) Project stage: RAI ML19072A1562019-03-14014 March 2019 Summary of Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx (W/Encl. 1&2) Project stage: RAI ML19126A0682019-04-0303 April 2019, 6 May 2019 Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: Request ML19105B2172019-04-19019 April 2019 Memorandum to C. Regan Summary of March 20, 2019, Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the Interim Storage Partners Consolidated Isf Application (W/Enclosures 1 and 2) Project stage: RAI ML19120A4282019-04-23023 April 2019 Letter to J. Isakson Interim Storage Partners Llc'S License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrews County, Texas, Dkt No. 72-1050 - First RAI (W/Enclosure) Project stage: RAI ML19126A0662019-05-0606 May 2019 Memorandum to C. Regan Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas (W/Enclosure 1 & 2) Project stage: RAI ML20015A4502019-05-31031 May 2019 Sprint Andrews County Disposal Facility, Andrews County, Texas- Railroad Commission of Texas Commercial Processing and Disposal Facility Permit Application Project stage: Other ML19150A5592019-06-0303 June 2019 Letter to J. Isakson Site Audit Plan for Interim Storage Partners Proposed Application for a Site-Specific License of an Away-from-Reactor Independent Spent Fuel Storage Installation Project stage: Other ML19156A1132019-06-0404 June 2019 Enclosuaudit Plan (Letter to E. Mayer Audit Plan for NRC Staff Visit of Proposed Site for the HI-STORE Consolidated Interim Storage Facility) Project stage: Other ML19156A1142019-06-0404 June 2019 Letter to E. Mayer Audit Plan for NRC Staff Visit of Proposed Site for the HI-STORE Consolidated Interim Storage Facility Project stage: Other ML19182A1072019-07-0101 July 2019 Letter to J. Isakson Interim Storage Partners Llc'S Application for a Specific ISFSI for the Waste Control Specialists Consolidated Interim Storage Facility for Spent Nuclear Fuel - Revised Review Schedule Project stage: Other ML19182A1472019-07-0101 July 2019 Letter to K. Manzione Holtec International'S Application for Specific ISFSI License for the HI-STORE Consolidated Interim Storage Facility for Spent Nuclear Fuel - Revised Review Schedule Project stage: Other ML20015A4512019-08-22022 August 2019 Report No. R1432-01, Acoustical Analysis of ISP Cisf Project stage: Other ML19322C2602019-11-14014 November 2019 Holtec International'S Application for Specific Independent Spent Fuel Storage Installation License for the Hi-Store Consolidated Interim Storage Facility for Spent Nuclear Fuel Project stage: Other ML20015A4542019-11-30030 November 2019 Socioeconomic Impacts of the Proposed Spent Nuclear Fuel Consolidated Interim Storage Facility, Andrews County, Texas, Revision 5 Project stage: Other ML19357A1762019-12-18018 December 2019 NAC International - Submission of a Request to Renew the U.S. Nuclear Regulatory Commission Certificate of Compliance No. 1025 for the NAC-MPC Cask System Project stage: Request ML19354A7142019-12-20020 December 2019 Approval of Tn America Request for Withholding Information from Public Disclosure for Coc 1029 Renewal Request for Supplemental Information Responses (CAC No. 001028) Project stage: Withholding Request Acceptance ML20002A4422019-12-20020 December 2019 International _Affidavit Project stage: Other ML19360A0472019-12-26026 December 2019 Internationals Application for Specific Independent Spent Fuel Storage Installation License for the Hi-Store Consolidated Interim Storage Facility for Spent Nuclear Fuel - Request for Clarification of Responses Related to Emergency Response Project stage: Approval ML20009D0512020-01-0606 January 2020 Notification of NRC Acceptance of the Standardized Advanced NUHOMS CoC 1029 Renewal Application for Review Project stage: Acceptance Review ML20009D0082020-01-0606 January 2020 Acknowledgement of NRC Receipt of CoC 1025 (NAC-MPC) Renewal Application Project stage: Other ML20015A4522020-01-0606 January 2020 Interim Storage Partners LLC - Submittal of Supplemental Information in Support of RAI, Part 3 - Clarification Related to the Response to RAI AQ-6 Project stage: Supplement ML19354B6372020-01-0707 January 2020 Exemption Request for NAC Magnastor Cask Loaded to Incorrect Helium Backfill Density Request for Additional Information Project stage: RAI ML20010D5642020-01-10010 January 2020 Proprietary Determination Letter for HI-STAR 100 CoC Renewal Submittals Project stage: Other ML20028E8462020-01-17017 January 2020 Enclosure 3 - RAIs and Responses Project stage: Other ML20028E8452020-01-17017 January 2020 Enclosure 1 - Affidavits Project stage: Other ML20031D0562020-01-29029 January 2020 Interim Storage Partners, LLC - Submittal of ISP Updated Draft Responses for Rals NP-8-1, NP-8-2 and Associated SAR Markups from First Request for Additional Information, Part 2, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Draft Request ML20049A0812020-01-31031 January 2020 Holtec International - HI-STORM 100 Storage CoC Renewal Application Project stage: Request ML20049A0822020-01-31031 January 2020 International - HI-STORM 100 Storage CoC Renewal Application Project stage: Other ML20034E8352020-02-0303 February 2020 Letter-Materials Request for Additional Information Clarification with Enclosure Project stage: RAI ML20034E9872020-02-11011 February 2020 Meeting Summary - Meeting with Westinghouse Electric Company, LLC, Pre-Application Amendment No. 5 of Storage CoC No. 1026 for the Fuelsolutions Spent Fuel Management System, November 21, 2019 Project stage: Meeting ML20052D9962020-02-14014 February 2020 Interim Storage Partners, LLC - Submission of ISP Responses for RAIs and Associated Document Markups from First Request for Additional Information, Part 2, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Request ML20052E1462020-02-17017 February 2020 Interim Storage Partners, LLC - Submittal of Revision 3 of the Environmental Report for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Other ML20052E1542020-02-17017 February 2020 WCS Consolidated Interim Spent Fuel Storage Facility Environmental Report, Revision 3 - Part 2 of 3 Project stage: Other ML20064F6162020-02-29029 February 2020 January 15, 2020, Summary of Meeting with Holtec International, Inc., to Discuss the Upcoming Submittal of the Application for Renewal of the Storage Certificate of Compliance No. 1014 for the HI-Storm 100 Cask System Project stage: Meeting ML20063M0152020-03-0303 March 2020 HI-STORM 100 Renewal Presubmittal Meeting (Holtec Slides, 1-15-20) Project stage: Meeting ML20064E6222020-03-0303 March 2020 U.S. Nuclear Regulatory Commission Approval of NAC International Request for Withholding Information from Public Disclosure for Coc 1025 Renewal (CAC No. 001028) Project stage: Withholding Request Acceptance ML20071F1562020-03-0505 March 2020 Interim Storage Partners, LLC - Affidavit Project stage: Other ML20071J0552020-03-0505 March 2020 Notice of Cancelled Meeting with the U.S. Department of Energy, Idaho Operations Office to Discuss the Upcoming Submittal of the Application for Renewal of the Idaho Spent Fuel Facility License (SNM-2512) Project stage: Meeting ML20065J4272020-03-0505 March 2020 Submittal of Renewal Application for the TN-32 Dry Storage Cask - CoC 1021 Project stage: Request ML20071F1532020-03-0505 March 2020 Interim Storage Partners, LLC - Supplemental Information in Support of NRCs Environmental Review Project stage: Supplement ML20066K5782020-03-0606 March 2020 Acceptance Review of Request for Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Acceptance Review 2019-05-31 |
ML23103A420 | |
Person / Time | |
---|---|
Site: | HI-STORE |
Issue date: | 05/09/2023 |
From: | Shana Helton Division of Fuel Management |
To: | Cooper D Apache Tribe of Oklahoma |
Shared Package | |
ML23103A414 | List: |
References | |
CAC 001028, EPID L-2018-NEW-0001 | |
Download: ML23103A420 (2) | |
Similar Documents at HI-STORE | |
---|---|
Category:Letter
MONTHYEARML24267A2392024-09-23023 September 2024
[Table view]Letter to E. C. Allison from Carrie M. Safford, Responds to Letter of September 10, 2024, Concerning Issuance of Licenses for Consolidated Interim Storage Facilities ML24257A1782024-09-10010 September 2024 Letter - E.C. Allison to Helton, 09-10-24 (Short Version) ML24256A1992024-09-10010 September 2024 Letter - E.C. Allison to J. Lubinski, 09-10-2024 (Short Version) ML24295A0752024-09-10010 September 2024 Letter - E.C. Allison to R Lewis, 09-10-2024 (Short Version) ML24257A0782024-09-10010 September 2024 Letter -E.C. Allison to J Lubinski, 09-10-24 (Full Report Version) ML24260A1162024-09-10010 September 2024 Letter - E.C. Allison to K. Morgan-Butler, 09-10-2024 (Short Version) ML24257A1792024-09-10010 September 2024 Letter - E.C. Allison to Helton 9-10-24 (Full Report Version) ML24260A1172024-09-10010 September 2024 Letter - E.C. Allison to C. Roman, 09-10-24 (Short Version) ML24260A1152024-09-0303 September 2024 Letter - E.C. Allison to K. Morgan-Butler, 09-03-24 (Short Version) ML24257A1812024-09-0303 September 2024 Letter - E.C. Allison to Helton 9-03-24 (Full Report Version) ML23257A1862023-09-27027 September 2023 Response Letter to Marcia Schneider Regarding Holtec Consolidated Interim Storage Facility ML23206A1782023-07-25025 July 2023 International, HI-STORE Cis (Consolidated Interim Storage Facility) Final Safety Analysis Report ML23125A1282023-05-10010 May 2023 Letter to E Mayer, Final Safety Evaluation Report for Physical Security, Security Training, and Safeguards Contingency Plan for the HI-STORE CISF ML23103A4192023-05-0909 May 2023 Letter to M. Woommavovaha, Comanche Nation, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4262023-05-0909 May 2023 Letter to M. A. Lente, Pueblo of Isleta, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4152023-05-0909 May 2023 Letter to E. Martinez, Mescalero Apache Tribe, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4212023-05-0909 May 2023 Letter to D. Jackson, Lea County Board of County Commissioners, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4232023-05-0909 May 2023 Letter to New Mexico Governor Lujan Grisham, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4182023-05-0909 May 2023 Letter to T. Nuvangyaoma, Hopi Tribe, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4202023-05-0909 May 2023 Letter to D. Cooper, Apache Tribe of Oklahoma, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4222023-05-0909 May 2023 Letter to W. Echo-Hawk, Pawnee Nation of Oklahoma, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4252023-05-0909 May 2023 Letter to E. M. Silvas, Pueblo of Ysleta Del Sur, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23055B1142023-05-0909 May 2023 Letter to K. Manzione, Holtec International, Issuance of Materials License No. SNM-2516 for the HI-STORE Consolidated Interim Storage Facility ISFSI ML23103A4172023-05-0909 May 2023 Letter to E. Velarde, Jicarilla Apache Tribe, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4272023-05-0909 May 2023 Letter to B. Nygren, Navajo Nation, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4162023-05-0909 May 2023 Letter to L. Spottedbird, Kiowa Tribe, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23103A4242023-05-0909 May 2023 Letter to M. Herrera, Pueblo of Tesuque, Re Issuance of Record of Decision and Materials License for Holtec HI-STORE CISF ML23116A1802023-05-0202 May 2023 Letter to K. Manzione, Holtec International, Re Request for Withholding Information from Public Disclosure - HI-STORE CISF License Application ML23076A2792023-03-20020 March 2023 Letter to K. Manzione, Holtec Internationals License Application for the HI-STORE CISF, Revised Schedule for Final Licensing Decision ML23096A0762023-03-14014 March 2023 CISF EIS - Species List New Mexico Ecological Services Field Office March 2023 ML23027A0322023-01-27027 January 2023 International, Letter Regarding Status of the NRC Review of the Joint HI-STORE Consolidated Interim Storage Facility (CISF) Between Holtec and the Eddy-Lea Energy Alliance ML23025A3502023-01-26026 January 2023 Letter to K. Manzione - Revised Review Schedule for Holtec Internationals License Application for the HI-STORE CISF ML23020A1292023-01-20020 January 2023 International HI-STORE Cis (Consolidated Interim Storage Facility) Additional Supplemental Information ML22357A1182022-12-23023 December 2022 International HI-STORE Cis (Consolidated Interim Storage Facility) Additional Supplemental Information ML22331A0032022-11-23023 November 2022 International HI-STORE Cis (Consolidated Interim Storage Facility) Additional Supplemental Information ML22299A1702022-10-28028 October 2022 Letter to William Nelson, Chairman, Comanche Nation; Re., Holtec CISF Supplement 1 ML22299A1612022-10-28028 October 2022 Letter to E. Michael Silvas, Governor, Yslea Del Sur Pueblo; Re., Holtec CISF Supplement 1 ML22299A1602022-10-28028 October 2022 Letter to Darrell Paiz, President, Jicarilla Apache Nation; Re., Holtec CISF Supplement 1 ML22299A1752022-10-28028 October 2022 Letter to Bobby Komardley, Chairman, Apache Tribe of Oklahoma; Re., Holtec CISF Supplement 1 ML22299A1682022-10-28028 October 2022 Letter to Timothy Nuvangyaoma, Chairman, Hopi Tribe; Re., Holtec CISF Supplement 1 ML22299A1692022-10-28028 October 2022 Letter to Walter Echo-Hawk, President, Pawnee Nation of Oklahoma; Re., Holtec CISF Supplement 1.docx ML22299A1632022-10-28028 October 2022 Letter to Gabe Aguilar, President, Mescalero Apache Tribe; Re., Holtec CISF Supplement 1 ML22299A1622022-10-28028 October 2022 Letter to Earl Samuel, Governor, Pueblo of Tesuque; Re., Holtec CISF Supplement 1 ML22299A1662022-10-28028 October 2022 Letter to Matthew Komalty, Chairman, Kiowa Tribe of Oklahoma; Re., Holtec CISF Supplement 1 ML22299A1642022-10-28028 October 2022 Letter to Joe Pat Padilla, Council President, Pueblo of Isleta; Re., Holtec CISF Supplement 1 ML22299A1652022-10-28028 October 2022 Letter to Jonathan Nez, President, Navajo Nation; Re., Holtec CISF Supplement 1 ML22300A1642022-10-27027 October 2022 Letter to Ed Mayer Re Notice of Availability of the Holtec CISF Final EIS Supplement 1 ML22227A1572022-08-15015 August 2022 International HI-STORE Cis (Consolidated Interim Storage Facility) Additional Supplemental Information ML22265A1932022-08-15015 August 2022 EPA Comment Letter for the NRC Holtec Spent Nuclear Fuel Final Environmental Impact Statement (Feis) ML22180A1372022-07-14014 July 2022 Feis Carlsbad Nm Library Letter 2024-09-03 |
Text
Durell Cooper, Chairman Apache Tribe of Oklahoma P.O. Box 1220 Anadarko, OK 73005
SUBJECT:
RECORD OF DECISION AND ISSUANCE OF LICENSE TO HOLTEC INTERNATIONAL FOR THE HI-STORE CONSOLIDATED INTERIM STORAGE FACILITY IN LEA COUNTY, NEW MEXICO (DOCKET NUMBER: 72-1051)
Dear Chairman Cooper:
On behalf of the U.S. Nuclear Regulatory Commission (NRC), I write to inform you that today I signed and issued a license under Title 10 of the Code of Federal Regulations (10 CFR), Part 72, Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste, to Holtec International (Holtec) to construct and operate the HI-STORE Consolidated Interim Storage Facility in Lea County, New Mexico. The license is issued pursuant to the NRCs authority under the Atomic Energy Act of 1954, as amended, based on the determination that Holtecs license application meets the standards and requirements of the Act and the NRCs regulations.
The NRC has also issued a record of decision in support of the NRCs decision to issue the license. Both documents will be available at Agencywide Documents Access and Management System (ADAMS) Package No. ML23075A179 by May 9, 2023. NRC maintains the ADAMS system, which provides text and image files of NRCs public documents. The ADAMS system is accessible on the Internet at http://www.nrc.gov/reading-rm/adams.html. If you do not have access to ADAMS or have problems accessing the documents located in ADAMS, please contact the NRC Public Document Room (PDR) staff at 1-800-397-4209, 301-415-4737, or pdr.resource@nrc.gov.
The license and record of decision will also be publicly available through the NRC web site at https://www.nrc.gov//waste/spent-fuel-storage/cis/holtec-international.html by May 9, 2023.
May 9, 2023
D. Cooper 2
Should you have any questions concerning the decision to issue the license, please contact Yoira Diaz-Sanabria of my staff at 301-415-8064, or via email at Yoira.Diaz-Sanabria@nrc.gov.
Sincerely, Shana R. Helton, Director Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1051 CAC/EPID No. 001028/07201051/
L-2018-NEW-0001 Signed by Helton, Shana on 05/09/23
ML23103A414; Ltr ML23103A420 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB OGC/GCRPS
/HLWFCNS/NLO NAME JCuadrado-Caraballo WWheatley YDiaz-Sanabria ABell DATE Apr 18, 2023 Apr 20, 2023 Apr 21, 2023 Apr 21, 2023 OFFICE NMSS/DFM NAME SHelton DATE May 9, 2023