International - HI-STORM Umax Amendment 4 FSAR - Changed Pages
ML20104C018
Person / Time
Site: HI-STORM 100, Consolidated Interim Storage Facility
Issue date: 03/30/2020
From:
Holtec
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML20104C014 List:
References
5021060, CAC 001028
Download: ML20104C018 (3)


Text

Table 2.3.2 DESIGN DATA FOR HI-STORM UMAX ISFSI Value (minimum or Type nominal, as Comment applicable)

Strain compatible effective This space may be remediated with

8. 485 ft/sec minimum shear wave velocity in Space vertical reinforcement such as C, V pilings to enhance V.

Strain compatible effective This space will typically contain native

9. shear wave velocity in Space 485 ft/sec minimum soil.

D, V (Figure 2.4.4)

Top of the Grade Horizontal and vertical spectra shown in (Ground surface) Figures 2.4.1 and 2.4.2 are based on 5%

spectra per Figure damping.

2.4.1 with Following the Newmark 100-40-40 horizontal ZPA, aH and response combination technique [2.6.7]

vertical ZPA, aV endorsed by the Regulatory Guide 1.92 scaled as follows: [2.4.7], the resultant ZPA for a 3-D earthquake site is defined as: aR=

aH = 1.0g a1+0.4a2+0.4a3, where a1, a2 and a3 are

10. Design Basis Earthquake aV = 0.75g the sites ZPAs in three orthogonal and foundation surface directions and a1a2a3.

pad spectra per Figure Hence, the DBE resultant ZPAs at 2.4.2 with horizontal ground surface and foundation surface ZPA, aH and vertical elevations are ZPA, aV of:

1.3 gs (=1.0x1.0gs + 0.4x0.75 gs) and aH = 0.93g 1.214 gs (=1.0x0.93gs + 0.4x0.71 gs),

a = 0.71g respectively.

V Permissible long-term Used as the input value in the strength

11. 0.2 inch maximum settlement of the SFP qualification of the SFP.

Density of plain concrete in 12 150 lb/cubic feet Used in shielding calculations the Closure Lid (min nom)

Reference compressive Used in analysis of mechanical loadings 13 strength of plain concrete in 4,000 psi on the Closure Lid the Closure Lid Minimum compressive Used in tornado missile impact analysis 14 strength of SES in Space A 1,000 psi and SSI analysis (see Figure 2.4.4)

Density of CEC plenum 15 120 lb/ cubic feet Used in shielding calculations shield concrete, if applicable HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Rev. 5B 2-86

Table 5.3.2 COMPOSITION OF THE MATERIALS IN THE HI-STORM FW SYSTEM Component Density (g/cm3) Elements Mass Fraction (%)

Metamic 2.642 B-10 4.388 B-11 20.436 Al 68.275 C 6.901 Metamic-HT [PROPRIETARY INFORMATION WITHHELD IN ACCORDANCE WITH 10 CFR 2.390]

Carbon steel 7.82 Fe 99.0 C 1.0 SS304 7.94 Cr 19.0 Mn 2.0 Fe 69.5 Ni 9.5 Concrete 2.4 (150 lb/ft3) O 53.2

[note 1 deleted] Si 33.7 Ca 4.4 Al 3.4 Na 2.9 Fe 1.4 H 1.0 Soil 1.7 H 0.962 O 54.361 Al 12.859 Si 31.818

[Note 1 deleted]

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 5C 5-28

Table 5.4.6 DOSE RATES ADJACENT TO THE HI-STORM UMAX MODULE WITH VERSION B LID FOR NORMAL CONDITIONS MPC-37 DESIGN BASIS ZIRCALOY CLAD FUEL Location Value Side of the VVM lid Adjacent 22 mremr/hr to the Inlet Vent Table 5.4.7 DESIGN BASIS DOSE RATE LIMITS Location Value Side of HI-TRAC 3500 mrem/hr Standard Lid 66 mremr/hr (On the side of the closure lid approximately midheight)

Version B Lid 22 mremr/hr (On the side of the closure lid approximately midheight and adjacent to the inlet vent)

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL HI-2115090 Proposed Rev. 5C 5-45