ML20052D787

From kanterella
Jump to navigation Jump to search

Submittal of HI-STORM FW Multipurpose Canister Storage System Amendment Request 1032-7
ML20052D787
Person / Time
Site: 07201032
Issue date: 02/07/2020
From: Manzione K
Holtec
To: Andrea Kock
Document Control Desk, Office of Nuclear Material Safety and Safeguards
Shared Package
ML20052D786 List:
References
5018075
Download: ML20052D787 (2)


Text

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018075 Page 1 of 2 February 7, 2020 Ms. Andrea Kock Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032

Subject:

Holtec International HI-STORM FW Multipurpose Canister Storage system Amendment Request 1032-7

Dear Ms. Kock:

We request DSFMs review of LAR#7 for our HI-STORM FW system which adds heat load patterns to facilitate efficient decommissioning of a nuclear plant planning to shut down. The proposed changes include a new heat load pattern for the MPC-89. The limited scope of this submittal is reflected in the extent of required changes to the FSAR, a summary of which is contained in Attachment 1. The proposed changes do not reduce any of the safety metrics including the computed margins of safety, operational flexibility or radiation protection features imbedded in the HI-STORM FW system. The new pattern follows the same thermal and shielding methodology already reviewed by the NRC under other amendments.

Based on the extremely limited scope, Holtec is requesting that this amendment be effective for use within 14 months. contains changes for the CoC and its appendices. Attachments 3 and 4 provide the proposed changed pages of the HI-STORM FW FSAR, which supports the LAR, in proprietary and non-proprietary versions. All proposed changes are provided in mark-up format to facilitate the Staffs review. Note that the marked changes are only those associated with LAR 1032-7.

Changes associated with previous amendments or revisions to amendment, up to and including HI-STORM FW Amendment 5, are included but not marked as changes, since that LAR request is already under NRC review.

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID 5018075 Page 2 of 2 Attachments 5 and 6 calculation packages for the changes requested in the thermal and shielding disciplines. Since these calculation packages are considered proprietary, Attachment 7 contains an affidavit in accordance with 10CFR2.390 requesting that the information be withheld from public disclosure.

Please contact at me (856) 797-0900 ext. 3951 if you have any questions.

Sincerely, Kimberly Manzione Licensing Manager, Holtec International cc:

(via email)

Ms. Yen-Ju Chen, USNRC Attachments: : Summary of Proposed Changes for HI-STORM FW LAR 1032-7 (non-proprietary) : Proposed CoC 1032 Amendment 7 (non-proprietary) : HI-STORM FW FSAR Proposed Changed pages (proprietary) : HI-STORM FW FSAR Proposed Changed pages (non-proprietary) : Thermal Calculation Package, HI-2094400R29, Appendix W (proprietary) : Shielding Calculation Package, HI-2094431R24, Appendix V (proprietary) : Affidavit Pursuant to 10 CFR 2.390 to Withhold Information from Public Disclosure