ML19186A212

From kanterella
Jump to navigation Jump to search

International - Attachment 2, Table 3.2.2, Limiting Parameters
ML19186A212
Person / Time
Site: 07201032
Issue date: 07/05/2019
From:
Holtec
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML19186A209 List:
References
5018070, CAC 001028, EPID L-2017-LLA-0030
Download: ML19186A212 (1)


Text

HOLTEC INTERNATIONAL COPYRIGHTED MATERIAL REPORT HI-2114830 Proposed Rev. 5.H 3-45 Table 3.2.2 LIMITING PARAMETERS Item PWR BWR

1.

Minimum fuel assembly length, inch 150 171

2.

Maximum fuel assembly length, inch 199.2 181.53 3a.

Nominal thickness of the lead cylinder in the lowest weight HI-TRAC VW, inch 2.75 (MPC-37) 2.50 3b.

Minimum thickness of the lead in the HI-TRAC VW, inch 3.25 (MPC-32ML)

4.

Maximum nominal thickness of the lead cylinder, inch 4.25 4.25

5.

Nominal (radial) thickness of the water in the external jacket, inch 4.75 4.75 3 Maximum fuel assembly length for the BWR fuel assembly refers to the maximum fuel assembly length plus an additional 5 to account for a Damage Fuel Container (DFC). to Holtec Letter 5018070 Page 1 of 1