ML19123A113

From kanterella
Jump to navigation Jump to search

Conversation Record with G. Mathues/Tn Americas LLC Clarification Call on RAI 1 Response for CoC 1042 Eos Amendment 1, Conversation Held on May 1, 2019
ML19123A113
Person / Time
Site: 07201042
Issue date: 05/03/2019
From: Christian Jacobs
Spent Fuel Licensing Branch
To: Mathues G
TN Americas LLC
Jacobs C
References
CAC 001028, EPID L-2018-LLA-0043
Download: ML19123A113 (2)


Text

NRC FORM 699 (03-2013)

U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD NAME OF PERSON(S) CONTACTED OR IN CONTACT WITH YOU Glenn Mathues E-MAIL ADDRESS glenn.mathues@orano.group ORGANIZATION TN Americas LLC LICENSE NUMBER(S)

Coe 1042 EOS Amendment # I SUBJECT DOCKET NUMBER(S) 72-1042 CONTROL NUMBER(S)

Clarification Call on RAJ # I response for CoC I 042 EOS Amendment# I.

SUMMARY

Participants:

DATE OF CONTACT 05/01 /2019 TELEPHONE NUMBER

( 410) 910-6538 DATE OF SIGNATURE 05/03/2019 TYPE OF CONVERSATION DE-MAIL

[Z] TELEPHONE D

INCOMING

[Zj OUTGOING TN: Prakash Narayanan, Peter Shih, Raheel Haroon, Yenkata Venigalla, Philippe Pham, Don Shaw, Hoi Yee Tom, Hui Liu, Laura Picard, Richard Migliore, Si Hwan Park, Jake Stefanick, Veeresh Sayagavi, Christophe Yiaud, Glenn Mathues NRC: Christian Jacobs, Travis Tate, John McKirgan, Veronica Wilson, JoAnn Irelan, Zhian Li, Meraj Rahimi, Darrell Dunn, Yen Chen, Continue on Page 2 ACTION REQUIRED (IF ANY)

TN to provide supplemental information to RAJ # I. Date not yet specified.

Continue on Page 3 NAME OF PERSON DOCUMENTING CONVERSATION Christian Jacobs SIGNA~ ~'"""'-----

NRC FORM 699 03-2013 I

Page 1 of 2

NRC FORM 699 (03-2013)

U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD (continued)

SUMMARY

(Continued from page 1)

A clarification call requested by NRC staff was held on May 1, 2019, with the applicant to seek clarification on responses to a request for additional information (RAJ # 1 ).

Specifically, NRC staff requested clarification on the responses to RAis 4-6, 6-4, 6-5, 6-7, 6-8, 6-9, 6-11, 6-16, 6-17, 6-18, 7-1, 8-2, 8-6, 8-7, and 9-2. Original responses to these RAis can be found in ADAMS Accession Number ML J 9058A410.

The applicant has agreed to provide supplemental information to support the completion of the review of CoC I 042 EOS Amendment

  1. I for the following RAis:

4-6 7-1 8-2 (items I and 2) 8-6 (Part I : items 2 and 5, and Part 2: item I) 8-7 (I, 2, 3, 4) 9-2 (1) 6-4 6-5 6-7 6-8 6-11 6-17 6-18 For RAis 6-9 and 6-16, TN provided clarification to NRC staff (specifically, that the information could be found in Table 6-30 and Table 6-8 respectively in the SAR). NRC staff has taken the action to re-review those tables and associated information in the SAR.

No further supplemental information is needed at this time with regard to RA!s 6-9 and 6-16.

Any correspondence or transmittal of supplemental information should include the following:

CAC: 001028 Docket: 72-1042 EPID: L-2018-LLA-0043 NRC FORM 699 (03-2013)

Page 2 of 2