{{#Wiki_filter:Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 July 13, 2022 Yen-Ju Chen, Sr. Project Manager Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 CAC No. 001028, EPID No. L-2021-LLA-0053
{{#Wiki_filter:Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909
 
July 13, 2022
 
Yen-Ju Chen, Sr. Project Manager Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards
 
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
 
Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 CAC No. 001028, EPID No. L-2021-LLA-0053


==Subject:==
==Subject:==
Line 29: Line 37:


==Dear Ms. Chen:==
==Dear Ms. Chen:==
By {{letter dated|date=July 11, 2022|text=letter dated July 11, 2022}} [2], Holtec responded to the NRCs request for additional information (RAIs) [1] needed to complete their review of HI-STORM FW Amendment 7 to the Certificate of Compliance No. 1032. Holtec indicated that we would provide additional supporting documents for the RAI responses. This letter contains those additional supporting documents in Attachments 1 and 2.


By {{letter dated|date=July 11, 2022|text=letter dated July 11, 2022}} [2], Holtec responded to the NRCs request for additional information (RAIs) [1] needed to complete their review of HI-STORM FW Amendment 7 to the Certificate of Compliance No. 1032. Holtec indicated that we would provide additional supporting documents for the RAI responses. This letter contains those additional supporting documents in Attachments 1 and 2.
Since Attachments 1 and 2 to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 3.
Since Attachments 1 and 2 to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 3.
Document ID 5018095 Page 1 of 2
Document ID 5018095 Page 1 of 2


Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3326.
Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909
Sincerely, Denise Elisio Licensing Engineer, Holtec International cc:(via email)
 
If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3326.
 
Sincerely,
 
Denise Elisio Licensing Engineer, Holtec International
 
cc:(via email)
Yoira Diaz-Sanabria (USNRC)
Yoira Diaz-Sanabria (USNRC)
Kimberly Manzione (Holtec)
Kimberly Manzione (Holtec)
Attachments: : Appendix Y to Holtec Report HI-2094431, HI-STORM FW and HI-TRAC VW Shielding Analysis (Revision 30) (proprietary) : Holtec Report HI-2200191, Thermal Analysis of HI-STORM FW UVH System (Revision 3) (proprietary) : Affidavit in Accordance with 10CFR2.390 Document ID 5018095 Page 2 of 2}}
 
Attachments: : Appendix Y to Holtec Report HI-2094431, HI-STORM FW and HI-TRAC VW Shielding Analysis (Revision 30) (proprietary) : Holtec Report HI-2200191, Thermal Analysis of HI-STORM FW UVH System (Revision 3) (proprietary) : Affidavit in Accordance with 10CFR2.390
 
Document ID 5018095 Page 2 of 2}}

Revision as of 08:10, 16 November 2024

International, HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 1 - Additional Supporting Documents
ML22194A954
Person / Time
Site: 07201032
Issue date: 07/13/2022
From: Elisio D
Holtec
To: Yen-Ju Chen
Document Control Desk, Office of Nuclear Material Safety and Safeguards
Shared Package
ML22194A953 List:
References
CAC 001028, EPID L-2021-LLA-0053, 5018095
Download: ML22194A954 (2)


Text

Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909

July 13, 2022

Yen-Ju Chen, Sr. Project Manager Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 CAC No. 001028, EPID No. L-2021-LLA-0053

Subject:

HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 1 - Additional Supporting Documents

Reference:

[1] Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System - Request for Additional Information First Batch, letter from Y. Chen (NRC) to D. Elisio (Holtec) dated June 10, 2022. ADAMS Accession No. ML22129A216.

[2] HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 1, letter from D. Elisio (Holtec) to Y. Chen (NRC) dated July 11, 2022. ADAMS Accession No. ML22192A216.

Dear Ms. Chen:

By letter dated July 11, 2022 [2], Holtec responded to the NRCs request for additional information (RAIs) [1] needed to complete their review of HI-STORM FW Amendment 7 to the Certificate of Compliance No. 1032. Holtec indicated that we would provide additional supporting documents for the RAI responses. This letter contains those additional supporting documents in Attachments 1 and 2.

Since Attachments 1 and 2 to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 3.

Document ID 5018095 Page 1 of 2

Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909

If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3326.

Sincerely,

Denise Elisio Licensing Engineer, Holtec International

cc:(via email)

Yoira Diaz-Sanabria (USNRC)

Kimberly Manzione (Holtec)

Attachments: : Appendix Y to Holtec Report HI-2094431, HI-STORM FW and HI-TRAC VW Shielding Analysis (Revision 30) (proprietary) : Holtec Report HI-2200191, Thermal Analysis of HI-STORM FW UVH System (Revision 3) (proprietary) : Affidavit in Accordance with 10CFR2.390