==Reference:==
==Reference:==
[1] HI-STORM Flood/Wind (FW) Storage System Amendment 7: Holtec Proposed Approach to NRCs Clarification Questions, Conversation Record between Holtec and   NRC   associates   dated February   28,   2024. ADAMS   Accession   No.
[1] HI-STORM Flood/Wind (FW) Storage System Amendment 7: Holtec Proposed Approach to NRCs Clarification Questions, Conversation Record between Holtec and NRC associates dated February 28, 2024. ADAMS Accession No.
ML24079A318.
ML24079A318.
[1] HI-STORM FW Amendment 7 RAI Response Clarifications (Part 5) Response Schedule, letter from D. Elisio (Holtec) to Y. Chen (NRC) dated March 13, 2024.
[1] HI-STORM FW Amendment 7 RAI Response Clarifications (Part 5) Response Schedule, letter from D. Elisio (Holtec) to Y. Chen (NRC) dated March 13, 2024.
Line 40: Line 40:


==Dear Ms. Chen:==
==Dear Ms. Chen:==
On a call February 28th, 2023, Holtec and the NRC discussed further clarification questions the NRC had on Amendment 7. The clarification questions were included as an attachment to the Conversation Record [1]. Holtec established plans to respond to the clarification questions by April 11th, 2024 [2]. A subsequent follow-up and check-in call occurred between Holtec and the NRC on March 20th, 2024 [3]. This letter contains the additional clarifications Holtec is submitting to the NRC for their review of Amendment 7.
On a call February 28th, 2023, Holtec and the NRC discussed further clarification questions the NRC had on Amendment 7. The clarification questions were included as an attachment to the Conversation Record [1]. Holtec established plans to respond to the clarification questions by April 11th, 2024 [2]. A subsequent follow-up and check-in call occurred between Holtec and the NRC on March 20th, 2024 [3]. This letter contains the additional clarifications Holtec is submitting to the NRC for their review of Amendment 7.
contains Holtecs responses to the clarification questions. Attachment 2 is a proprietary copy of the responses. Changes to the FSAR resulting from the additional clarifications are included in Attachments 3 and 4 for both proprietary and non-proprietary versions, respectively. All proposed changes in Attachments 3 and 4 based on the RAI response Document ID 5018117 Page 1 of 3 Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909
contains Holtecs responses to the clarification questions. Attachment 2 is a proprietary copy of the responses. Changes to the FSAR resulting from the additional clarifications are included in Attachments 3 and 4 for both proprietary and non-proprietary versions, respectively. All proposed changes in Attachments 3 and 4 based on the RAI response Document ID 5018117 Page 1 of 3 Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909


clarifications are highlighted in blue to facilitate the NRC staffs review. Attachments 5 through 9 contain proprietary supporting documents.
clarifications are highlighted in blue to facilitate the NRC staffs review. Attachments 5 through 9 contain proprietary supporting documents.


Since some attachments to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 10.
Since some attachments to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 10.


If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3326.
If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3326.

Latest revision as of 18:07, 4 October 2024

HI-STORM FW Amendment 7 RAI Response Clarifications (Part 5)
ML24100A028
Person / Time
Site: 07201032
Issue date: 04/08/2024
From: Elisio D
Holtec
To: Yen-Ju Chen
Office of Nuclear Material Safety and Safeguards, Document Control Desk
Shared Package
ML24100A027 List:
References
5018117, CAC 001028, EPID L-2021-LLA-0053
Download: ML24100A028 (1)


Text

Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909

April 8, 2024

Yen-Ju Chen, Sr. Project Manager Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards

U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 CAC No. 001028, EPID No. L-2021-LLA-0053

Subject:

HI-STORM FW Amendment 7 RAI Response Clarifications (Part 5)

Reference:

[1] HI-STORM Flood/Wind (FW) Storage System Amendment 7: Holtec Proposed Approach to NRCs Clarification Questions, Conversation Record between Holtec and NRC associates dated February 28, 2024. ADAMS Accession No.

ML24079A318.

[1] HI-STORM FW Amendment 7 RAI Response Clarifications (Part 5) Response Schedule, letter from D. Elisio (Holtec) to Y. Chen (NRC) dated March 13, 2024.

ADAMS Accession No. ML24073A336.

[3] HI-STORM Flood/Wind (FW) Storage System Amendment 7: Check-in on response progress, Conversation Record between Holtec and NRC associates dated March 20, 2024. ADAMS Accession No. ML24092A227.

Dear Ms. Chen:

On a call February 28th, 2023, Holtec and the NRC discussed further clarification questions the NRC had on Amendment 7. The clarification questions were included as an attachment to the Conversation Record [1]. Holtec established plans to respond to the clarification questions by April 11th, 2024 [2]. A subsequent follow-up and check-in call occurred between Holtec and the NRC on March 20th, 2024 [3]. This letter contains the additional clarifications Holtec is submitting to the NRC for their review of Amendment 7.

contains Holtecs responses to the clarification questions. Attachment 2 is a proprietary copy of the responses. Changes to the FSAR resulting from the additional clarifications are included in Attachments 3 and 4 for both proprietary and non-proprietary versions, respectively. All proposed changes in Attachments 3 and 4 based on the RAI response Document ID 5018117 Page 1 of 3 Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909

clarifications are highlighted in blue to facilitate the NRC staffs review. Attachments 5 through 9 contain proprietary supporting documents.

Since some attachments to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 10.

If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3326.

Sincerely,

Denise Elisio

Licensing Engineer, Holtec International

cc:(via email)

Yoira Diaz-Sanabria (USNRC)

Kimberly Manzione (Holtec)

Attachments: : Summary of Additional Clarifications Submitted for Review (proprietary) : Summary of Additional Clarifications Submitted for Review (non-proprietary) : HI-STORM FW FSAR Proposed Revision 10L, changed pages (proprietary) : HI-STORM FW FSAR Proposed Revision 10L, changed pages (non-proprietary) : Appendixes B, C, D, F, and G to Holtec Report HI-2200503 Revision 9, Analysis of the Non-Mechanistic Tipover Event of the Loaded HI-STORM FW Version E Storage Cask (proprietary) : Appendixes B, F, G, N, and N1 to Holtec Report HI-2094353 Revision 21, Analysis of Non-Mechanistic Tipover and Drop Events of Loaded HI-STORM FW Storage Cask (proprietary) : Appendix D to Holtec Report HI-2210313 Revision 3, Analysis of the Non-Mechanistic Tipover Event of the Loaded HI-STORM FW Version UVH Storage Cask (proprietary) : Holtec Report HI-2166998 Revision 4, Analysis of the Non-Mechanistic Tipover

Document ID 5018117 Page 2 of 3 Holtec Technology Campus, One Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909

Event of the HI-STORM FW Storage Cask Loaded with MPC-32ML (proprietary) : Holtec Dry Storage Position Paper DS-331, Structural Acceptance Criteria for the Metamic-HT Fuel Basket, Revision 4 (proprietary) 0: Affidavit in Accordance with 10CFR2.390

Document ID 5018117 Page 3 of 3