Letter Sequence RAI |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, ... further results|Supplement]]
Administration
- Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance, Withholding Request Acceptance
- Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, Meeting, ... further results|Meeting]]
Results
- Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, Approval, ... further results|Approval]]
Other: L-18-006, ISFSI - Site-Specific License Renewal Application, Revision 0, July 2018, L-23-005, Independent Spent Fuel Storage Installation License Renewal Application, Revision 1 (Cac/Epid No. 001028/L-2022-RNW-0007), ML17311A450, ML17318A087, ML18018A018, ML18022A077, ML18022A078, ML18022A079, ML18087A056, ML18087A057, ML18087A058, ML18087A059, ML18087A060, ML18087A061, ML18087A062, ML18100A185, ML18100A188, ML18100A190, ML18100A191, ML18100A193, ML18101A024, ML18108A052, ML18131A047, ML18131A048, ML18141A561, ML18141A562, ML18141A563, ML18141A564, ML18141A565, ML18141A567, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18205A179, ML18222A351, ML18228A530, ML18228A531, ML18228A532, ML18228A533, ML18234A012, ML18248A121, ML18255A093, ML18255A094, ML18255A096, ML18255A097, ML18255A098, ML18255A101, ML18255A102, ML18324A577... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A0572018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update) Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18057A2172018-02-23023 February 2018 Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update Project stage: RAI 2018-01-10
[Table View] |
Text
Denise Elisio Licensing Engineer Holtec International Holtec Technology Campus 1 Holtec Blvd.
Camden, NJ 08104
SUBJECT:
AMENDMENT NO. 16 TO CERTIFICATE OF COMPLIANCE NO. 1014 FOR THE HI-STORM 100 MULTIPURPOSE CANISTER STORAGE SYSTEM -
REQUEST FOR ADDITIONAL INFORMATION FIRST BATCH
Dear Denise Elisio:
By letter dated March 9, 2021 [Agencywide Documents Access and Management System (ADAMS) Accession No. ML21068A360] and supplemented by letters dated August 11, 2021 (ML21223A045), and January 28, 2022 (ML22028A372), Holtec International (Holtec) submitted to the U.S. Nuclear Regulatory Commission a request to amend the Certificate of Compliance No. 1014 for HI-STORM 100 Multipurpose Canister Storage System. By a letter dated February 17, 2022 (ML22048C222), Holtec requested to separate the portion implementing Graded Approach (ML19353D337) from the Amendment No. 16 application.
The NRC staff reviewed your application and determined the need for additional information.
Due to resources and schedules, we will issue staggered requests for additional information (RAIs). The enclosure to this letter contains RAIs for all disciplines except structural, shielding, and materials. We plan to issue the second batch of RAIs in August 2022. We request that you provide the responses to these RAIs within 30 days from the date of this letter. If you are unable to meet this deadline, please notify us in writing, within two weeks of receipt of this letter, of your new submittal date and the reasons for the delay.
July 1, 2022
D. Elisio 2
Please reference Docket No. 72-1014, CAC No. 001028 and EPID No. L-2021-LLA-0039 in future correspondence related to this licensing action. If you have any questions, please contact me at 301-415-1018.
Sincerely, Yen-Ju Chen, Sr. Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1014 CAC No.: 001028 EPID No.: L-2021-LLA-0039
Enclosure:
RAI First Batch Signed by Chen, Yen-Ju on 07/01/22
D. Elisio 3
SUBJECT:
AMENDMENT NO. 16 TO CERTIFICATE OF COMPLIANCE NO. 1014 FOR THE HI-STORM 100 MULTIPURPOSE CANISTER STORAGE SYSTEM -
REQUEST FOR ADDITIONAL INFORMATION FIRST BATCH, DOCUMENT DATE:
DISTRIBUTION PKoch, DFM HLindsay, DFM EGoldfeiz, DFM LHowe, DFM J Colaccino, DFM MDiaz-Maldonado, DFM ADAMS Accession Number: ML22167A120 (Ltr and Enc)
OFFICE:
NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NAME:
YChen WWheatley JChang JWoodfield DATE:
6/16/2022 6/21/2022 6/16/2022 6/21/2022 OFFICE:
NMSS/DFM NMSS/DFM NMSS/DFM NAME:
DMarcano ARivera-Varona BWhite for YDiaz-Sanabria DATE:
6/22/2022 6/29/2022 6/30/2022 OFFICIAL USE ONLY July 1, 2022
Enclosure Request for Additional Information Docket No. 72-1014 Certificate of Compliance No. 1014 Amendment No. 16 to HI-STORM 100 Multipurpose Canister Storage System The staff identified additional information needed in connection with its review of the application of Amendment No. 16 to the Certificate of Compliance (CoC) No. 1014 for HI-STORM 100 Multipurpose Canister Storage System as provided in the request for additional information (RAI) discussed below. Each question describes information needed by the staff to complete its review of the application and to determine whether the applicant has demonstrated compliance with regulatory requirements in Title 10 of the Code of Federal Regulations (10 CFR), Part 72.
Thermal RAI RAI 4-1 (A) Justify the use of concrete conductivity of 1.50 Btu/hr-ft-°F for the HI-STORM 100 unventilated with high density concrete (UVH) overpack and (B) describe how conduction test is determined and performed at the site for using a higher concrete conductivity (>1.50 Btu/hr-ft-°F) for the UVH overpack.
The applicant listed a minimum concrete conductivity of 1.50 Btu/hr-ft-°F in the proposed final safety analysis report (FSAR) table 1.D.1 for the UVH overpack and stated in Note 3 of table 1.D.1 that the listed value of thermal conductivity is a lower bound and is considered to be acceptable a priori as in most cases it would likely be exceeded. A higher conductivity of plain concrete may be used in a site-specific safety qualification if supported by appropriate conduction tests.
(A)
A concrete conductivity of 1.05 Btu/hr-ft-°F (FSAR Revision 20 [ADAMS Accession No. ML20167A018] table 4.2.2) was used for the ventilated overpack. Justify the use of the concrete conductivity of 1.50 Btu/hr-ft-°F for the UVH overpack. Using a higher concrete conductivity (1.50 Btu/hr-ft-°F) for the UVH overpack is considered less conservative for analysis.
(B)
Describe how the conduction test is determined and performed at the site for using a higher concrete conductivity (>1.50 Btu/hr-ft-°F) for the UVH overpack.
The staff needs this information to determine compliance with 10 CFR 72.236(f).
RAI 4-2 Justify in the application: (A) the different temperature limits for overpack inner shell and remainder of the overpack steel structure ONLY under long-term normal condition of storage and (B) the temperature limit of the multipurpose canister (MPC) baseplate is changed from 400°F (Amendment No. 15, FSAR Revision 22
[ML21221A329]) to 440°F in the proposed FSAR table 2.2.3 for long-term normal condition of storage.
(A)
The proposed FSAR Table 2.2.3 shows that both overpack inner shell and remainder of the overpack steel structure share the same temperature limits of 700°F, 800°F, and 450°F for short-term events, off-normal condition, and
2 accident condition, respectively, but have different temperature limits for long-term normal condition (475°F for overpack inner shell and 400°F for remainder of the overpack inner shell) while both components are made of steel. Justify the different temperature limits used for overpack inner shell and remainder of the overpack steel structure under long-term normal condition of storage.
(B)
Justify the temperature limit of the MPC baseplate is changed from 400°F (Amendment No. 15) to 440°F in the proposed FSAR Table 2.2.3 for long-term normal condition of storage while the temperature limits remain unchanged for off-normal and accident conditions of storage.
This information is needed to determine compliance with 10 CFR 72.236(f).
RAI 4-3 Demonstrate the initial backfill pressure limits for MPC helium and annulus air pressure, shown in the proposed FSAR table 4.IV.1.3, are adequate for heat removal for MPC-32M and MPC-68M stored in HI-STORM UVH overpack.
The applicant provided initial backfill pressure limits for MPC helium and annulus air, in the proposed FSAR table 4.IV.1.3, for MPC-32M and MPC-68M stored in the UVH overpack. The applicant needs to provide derivations (e.g., calculations) in the application to demonstrate the initial backfill pressure limits in the proposed FSAR table 4.IV.1.3 are adequate for heat removal for the UVH overpack.
This information is needed to determine compliance with 10 CFR 72.236(f).
RAI 4-4 Provide information to Questions (A) and (B) below for using nitrogen (or another non-oxidizing gas) for backfill gas within MPC and annulus of the UVH overpack.
The applicant stated, in the proposed FSAR section 8.IV.1.7, step 7, that evacuate air within the MPC and the annulus of the UVH overpack and replace air with dry nitrogen (or another non-oxidizing gas) using couplings provided in the small penetrations in the cask body. The applicant provided the description of the UVH overpack annulus evacuation system and the nitrogen (or another non-oxidizing gas) backfill system in the proposed FSAR table 8.IV.1.6. The applicant also stated, in FSAR section 8.IV.1.7, step 7, that the target fill pressure of the non-oxidizing fill gas shall be as indicated in table 4.IV.1.3.
(A)
Nitrogen (or another non-oxidizing gas) has different material properties from helium (e.g., viscosity, thermal conductivity, etc.), and the difference in properties may cause changes in flow pattern and heat removal capacity within the MPC. With differences existing in material properties between helium and nitrogen (or another non-oxidizing gas), justify the target backfill pressure limits of the non-oxidizing fill gas remain the same as the backfill pressure limits for the helium, as indicated in table 4.IV.1.3, set for the MPC and the annulus for MPC32M and MPC-68M stored within the UVH overpack.
(B)
Clarify whether the annulus of the UVH overpack can be filled with the air when the MPC is backfilled with nitrogen (or another non-oxidizing gas) for storage.
This information is needed to determine compliance with 10 CFR 72.236(f).
3 Operating Procedure RAI 8-1 Revise the proposed FSAR section 8.IV.1.7 to provide clear step-by-step instructions on the installation of lid studs, washers, and hex nuts after the lid is placed on top of the gasket, prior to movement of the storage cask to the ISFSI pad.
In HI-STORM 100 Amendment No. 16 proposed FSAR, section 8.IV.0, Introduction, states:
The operations associated with the use of the HI-STORM 100 UVH system, are like the operations for the standard HI-STORM 100 system. The following sections describe those operations that are, in any respect, unique to the HI-STORM 100 UVH system and thus supplement the information presented in Chapter 8. Where practical, the section numbers used below directly reference the corresponding sections in Chapter 8. For example, Section 8.IV.3.5 supplements the operations described in Subsection 8.3.5. The guidance provided in this supplement shall be used along with the operations procedures provided in Chapter 8 to develop the site-specific operating procedures for the HI-STORM 100 UVH.
The proposed FSAR section 8.IV.1.7, Placement of HI-STORM 100 UVH into Storage, states that it shall incorporate the following instructions as additional steps to the generic guidance in section 8.1.6 (should be 8.1.7) on loading operations for unventilated cask models in the official HI-STORM 100 FSAR revision 23 (ML22108A277).
The proposed FSAR section 8.IV.1.7 step 1 states, Before installing the Closure Lid on the cask body, the lid gasket is placed on the top of the casks top ring.
The proposed FSAR section 8.IV.1.7 step 3 states, Place cask lid on top of the gasket.
The proposed FSAR section 8.IV.1.7 step 5 states, After the cask is placed in its storage location on the ISFSI pad install lid studs, washers, and hex nuts onto the cask.
The proposed FSAR section 8.IV.1.7 step 6 states, Tighten lid hex nuts to the point of contact with the washer. Then loosen nut to provide a nominal axial gap of 0.5 inches.
In the official HI-STORM 100 FSAR revision 23, the existing section 8.1.7, Placement of HI-STORM into Storage, step 18.a states: Remove the alignment device. Step 18.e states: Install the HI-STORM lid and the lid studs and nuts or lid closure bolts. See Table 8.1.5 for bolting Requirements. Step 18.i states: Secure HI-STORM to the transporter device as necessary. Step 20 states: Transfer the HI-STORM to its designated storage location at the appropriate pitch.
It is clear from the existing instruction in FSAR section 8.1.7, steps 18.a, 18.e, 18.i and 20, that a ventilated overpack lid must be mechanically fastened down (attached) to the overpack body prior to transferring the HI-STORM 100 to its storage location at an ISFSI. However, it is not clear whether the cask lid for the UVH is to be mechanically fastened down (attached) to the overpack body after placing the lid on
4 top of the gasket prior to transferring the MPC loaded HI-STORM 100 UVH to its storage location at an ISFSI. The proposed FSAR section 8.IV.1.7 step 5 only states that after the UVH cask is in its storage location on the ISFSI pad to install the lid studs, washers, and hex nuts onto the cask.
With the lid resting on the UVH cask without fastening it to the cask during cask transport is an unanalyzed condition. The UVH cask cannot be transported to its final location on a ISFSI pad after the stack up operation and having its lid placed on the top of the gasket without being mechanically fastened (attached) to the UVH cask. If a transport trailer is used to transport a MPC loaded UVH cask, the cask lid must first be mechanically attached to the UVH cask. Provide clear new step-by-step instructions in FSAR section 8.IV.1.7 that after the lid is placed on the top of the gasket, how will the lid studs, washers, and hex nuts be installed and the lid hex nuts hand tightened to contact the washers. Only after the UVH cask is at its final ISFSI location shall the nuts be loosened to provide a 0.5-inch axial gap.
If a Vertical Cask Transporter (VCT) is used to transport a MPC loaded UVH cask, revise the proposed FSAR section 8.IV.1.7 to provide procedural steps on how to attach the VCT special lifting devices so that the mechanical connection does not crush the gasket under the lid. If a VCT is used for transport, only after the UVH cask is at its final location on the ISFSI pad and the VCT special lifting devices removed, invoke new section 8.IV.1.7 steps 5 and 6.
This information is needed to determine compliance with 10 CFR 72.234(f).
Editorial Changes Consider the following editorial changes to the HI-STORM 100 Amendment No. 16 proposed FSAR:
A) In section 8.IV.1 paragraph, change Subsection 8.1.1 through 8.1.5 to Subsection 8.1.1 through 8.1.6.
B) In section 8.IV.1.7 first paragraph change Section 8.1.6 to Section 8.1.7.
C) Table 8.IV.1.8 should reference main table 8.1.8 instead of table 8.2.3.
D) The paragraph in section 8.IV.4 should reference section 8.4 instead of section 8.3.
E) The first sentence of the section 8.IV.5 paragraph should read: When the MPC is received from transport and transferred to a HI-STORM 100 UVH Overpack the procedures from Section 8.5 are used. The current statement is incorrect.
F) The paragraph in section 9.IV.2 should reference Supplement IV, not #I.
G) The sentence in section 9.IV.2.3 should read: The HI-STORM 100 UVH does not have vents and will not have the option of a monitoring system which must be maintained.
Ltr ML22167A120 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/CTCFB NMSS/DFM/IOB NAME YChen WWheatley FChang JWoodfield DATE Jun 16, 2022 Jun 21, 2022 Jun 21, 2022 Jun 21, 2022 OFFICE OEDO NMSS/DFM/CTCFB NMSS/DFM/STLB NMSS/DFM/STLB NAME ARivera-Varona DMarcano YDiaz-Sanabria BWhite for YChen DATE Jun 29, 2022 Jun 22, 2022 Jun 30, 2022 Jul 1, 2022