Denise Elisio Holtec International Holtec Technology Campus 1 Holtec Blvd.

Camden, NJ 08104

SUBJECT:

AMENDMENT NO. 7 TO CERTIFICATE OF COMPLIANCE NO. 1032 FOR THE HI-STORM FLOOD/WIND MULTIPURPOSE CANISTER STORAGE SYSTEM -

REQUEST FOR ADDITIONAL INFORMATION BATCH 5

Dear Denise Elisio:

By a letter dated May 6, 2021 (Agencywide Documents Access and Management System

[ADAMS] Accession No. ML21126A266) and supplemented by letters dated October 15, 2021 (ML21288A521), February 17, 2022 (ML22048C221), July 11, 2022 (ML22192A215), July 13, 2022 (ML22194A954), July 29, 2022 (ML22210A145), September 15, 2022 (ML22258A250),

October 3, 2022 (ML22276A281), December 1, 2022 (ML22336A132), and January 6, 2023 (ML23006A263), Holtec International submitted to the U.S. Nuclear Regulatory Commission a request to amend the Certificate of Compliance No. 1032 for HI-STORM Flood/Wind Multipurpose Canister Storage System, as Amendment No. 7.

The staff reviewed the application and supplemental information, and determined additional information is needed to complete this review. The enclosed request for additional information (RAI) contains 11 structural RAIs. We request that you provide the responses to these RAIs within 30 days from the date of this letter. If you are unable to meet this deadline, please notify us in writing, within 2 weeks of receipt of this letter, of your new submittal date and the reasons for the delay.

March 23, 2023

D. Elisio 2

Please reference Docket No. 72-1032, CAC No. 001028, and EPID No. L-2021-LLA-0053 in future correspondence related to this licensing action. If you have any questions, please contact me at 301-415-1018.

Sincerely, Yen-Ju Chen, Sr. Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1032 CAC No.: 001208 EPID: L-2021-LLA-0053

Enclosure:

Request for Additional Information Signed by Chen, Yen-Ju on 03/23/23

ML23074A101; Ltr ML23074A102 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/MSB NMSS/DFM/MSB NAME YChen WWheatley JCurry for PKoch TBoyce DATE Mar 20, 2023 Mar 22, 2023 Mar 21, 2023 Mar 22, 2023 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NAME YDiaz-Sanabria YChen DATE Mar 22, 2023 Mar 23, 2023