Letter Sequence Request |
|---|
EPID:L-2021-LLA-0053, Attachment 2: Updated Summary of Proposed Changes (non-proprietary) (Approved, Closed) CAC:001028, ECCS Response Time Testing (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance
- Supplement
Results
Other: ML21237A176, ML21237A177, ML21288A542, ML22192A218, ML22192A219, ML22192A220, ML22192A222, ML22192A225, ML22194A957, ML22210A147, ML22210A149, ML22210A150, ML22210A153, ML22258A251, ML22336A133, ML22336A135, ML23006A266, ML23006A267, ML23006A268, ML23006A270, ML23006A274, ML23074A102, ML23096A301, ML23128A305, ML23128A307, ML23128A313, ML23181A193, ML23181A194, ML23181A198, ML23181A201, ML23192A032, ML23192A033, ML23192A035, ML23227A249, ML23227A250, ML23227A252, ML23321A246, ML23321A247, ML23321A249, ML23321A254, ML24047A324, ML24065A303, ML24067A184, ML24079A319, ML24100A028, ML24100A030, ML24100A032, ML24100A038, ML24199A238, ML24199A239... further results
|
MONTHYEARML19255E7911997-05-31031 May 1997 Enclosure 1 - Ecological Assessment of the Low Level Waste Depository, Andrews County, Tx Project stage: Other ML19255E7952004-10-25025 October 2004 Enclosure 2 - Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository, Andrews County, Tx Project stage: Other ML19255E7982007-03-16016 March 2007 Enclosure 3 - Supplemental Survey to Ecological Assessment of the Low Level Waste Depository, Andrews County, Texas Project stage: Supplement ML19337B5182007-03-16016 March 2007 Enclosure 10 - Applicable Sections of LLRW License Project stage: Other ML19217A2112007-04-30030 April 2007 Enclosure 1 - Report on Mapping of a Trench Through Pedogenic Calcrete (Caliche) Across a Drainage and Possible Lineament, Waste Control Specialists Disposal Site, Andrews County, Tx (Public) Project stage: Other ML19255E8002008-07-0303 July 2008 Enclosure 4 - Environmental Assessment Report Prepared for Application for Renewal of Radioactive Material License R04971 Waste Control Specialists LLC Andrews County, Texas Project stage: Request ML19217A2142008-07-28028 July 2008 Enclosure 4 - Report on Activities to Satisfy Byproduct RML Conditions 41A, 41C, and 43, July 2008 (Public) Project stage: Other ML19217A2132011-02-22022 February 2011 Enclosure 3 - Oag Water Levels: Empirical and Modeled Relationships Between Precipitation and Infiltration, 2011 (Public) Project stage: Other ML18100A1852013-04-11011 April 2013 Enclosure 6 - Procedure 12751-MNGP-OPS-01, Revision 0, Spent Fuel Cask Welding: 61BT/BTH NUHOMS Canisters Project stage: Other ML18100A1882013-04-11011 April 2013 Enclosure 7 - Procedure 12751-MNGP-QP-9.201, Revision 0, Visual Weld Examination Project stage: Other ML18100A1912014-01-30030 January 2014 Enclosure 9 - Structural Integrity Associates, Inc. Report 130415.402, Revision 0, Review of Trivis Inc. Welding Procedures Used for Field Welds on the Transnuclear NUHOMS 61BTH Type 1 & 2 Transportable Canister for BWR Fuel Project stage: Other ML18100A1902014-05-22022 May 2014 Enclosure 8 - Structural Integrity Associates, Inc. Report 130415.403, Revision 2, Assessment of Monticello Spent Fuel Canister Closure Plate Welds Based on Welding Video Records Project stage: Other ML17318A0872017-11-0909 November 2017 Intent to Pursue Subsequent License Renewal Project stage: Other ML18011A1582017-12-22022 December 2017 International HI-STORE Cis (Consolidated Interim Storage Facility) License Application Responses to Safeguards Related Requests for Supplemental Information Project stage: Supplement ML18016A7232018-01-10010 January 2018 1/10/2018, E-Mail from D. Shaw/Areva to C. Jacobs/Nmss/Dsfm Urgent Need for a Tech Spec Administrative Change Project stage: Request ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML18022A1512018-01-16016 January 2018 Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay Independent Spent Fuel Storage Installation License Project stage: Meeting ML18022A1542018-01-16016 January 2018 Enclosure 3: Handout-PG&E Presentation on Humboldt Bay ISFSI LRA (Memo to A. Hsia Summary of December 12, 2017, Meeting) Project stage: Meeting ML18022A1522018-01-16016 January 2018 Enclosure 1: Meeting Attendees (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML18022A1532018-01-16016 January 2018 Enclosure 2: Agenda (Memo to A. Hsia Summary of December 12, 2017, Meeting with Pacific Gas & Electric Company to Discuss the Upcoming Submittal of the Application for Renewal of the Humboldt Bay ISFSI License) Project stage: Meeting ML18018A0192018-01-17017 January 2018 Enclosurequest for Additional Information (Ltr to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040-Accepted for Review) Project stage: RAI ML18018A0182018-01-17017 January 2018 Letter to K. Manzione Application for Holtec International HI-STORM Umax Multipurpose Canister Storage System License Amendment Request No. 3 to Certificate of Compliance No. 1040 - Accepted for Review Project stage: Other ML18018B2972018-01-19019 January 2018 Federal Registered Notice: Correction of Certificate of Compliance No. 1004, Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A6122018-01-19019 January 2018 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System-Request for Additional Information Project stage: RAI ML18022A0772018-01-22022 January 2018 Letter to J. Bondre Correction to Tn Americas LLC Technical Specifications for Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 to Standardized NUHOMS Certificate of Compliance No. 1004 for Spent Fuel Storage Casks Project stage: Other ML18022A0782018-01-22022 January 2018 Enclosure 1: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 11, Revision 1 Enclosure 1 Project stage: Other ML18022A0762018-01-22022 January 2018 Package: Correction to Title of Figure 1-15 in Technical Specifications for Certificate of Compliance 1004 Renewed Amendments No. 11, Revision 1 and No. 13, Revision 1 Project stage: Request ML18022A0792018-01-22022 January 2018 Enclosure 2: Revised Title for Figure 1-5 Corrected Technical Specifications for Certificate of Compliance No. 1004 Renewed Amendment No. 13, Revision 1 Project stage: Other ML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML17311A4502018-01-31031 January 2018 ISFSI License Renewal Final Environmental Assessment Project stage: Other ML18031A4572018-01-31031 January 2018 Submittal Date for Response to NRCs Requests for Additional Information (Rais) for License Amendment Request 1032-4 to HI-STORM FW CoC No. 1032 (CAC No. 001028) Project stage: Request ML18036A2222018-02-0101 February 2018 International - Transmittal of HI-STORM Umax License Amendment Request No. 3 - Administrative RAI Response Project stage: Request ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2272018-02-0606 February 2018 Enclosurenewed License SNM-2507 Technical Specifications (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2242018-02-0606 February 2018 Enclosure 1: Preamble-SNM-2507 License Renewal Order (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2222018-02-0606 February 2018 Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Approval ML18031A2282018-02-0606 February 2018 Enclosure 2: Safety Evaluation Report (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18031A2252018-02-0606 February 2018 Enclosurenewed License SNM-2507 (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation) Project stage: Approval ML18031A2312018-02-0808 February 2018 Federal Register Notice - Notice of Issuance for License Renewal (Letter to D. G. Stoddard Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station ISFSI) Project stage: Approval ML18053A2342018-02-15015 February 2018 Enclosure 6: Proposed Amendment 1, Revision 0 Changes to the NUHOMS Eos System Updated Final Safety Analysis Report, Chapters 1 to 14 Project stage: Request ML18053A2222018-02-15015 February 2018 Application for Amendment 1 to the NUHOMS Eos System, Revision O (Docket No. 72-1042) Project stage: Request ML18053A2332018-02-15015 February 2018 Enclosure 4: CoC 1042 Amendment 1 Proposed Technical Specifications, Revision 0 Project stage: Request ML18058A6082018-02-23023 February 2018 HI-2177593, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Underground CISF - Financial Assurance & Project Life Cycle Cost Estimates Project stage: Request ML18058A0242018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation) Project stage: RAI ML18057A2182018-02-23023 February 2018 Enclosurequest for Additional Information (Letter to A. Zaremba Request for Additional Information for Review of Duke Energys Decommissioning Funding Plan Update) Project stage: RAI ML18058A0232018-02-23023 February 2018 Letter to G. Van Noordennen Request for Additional Information Regarding Zionsolutions, LLCs Decommissioning Funding Plan Update for Zion Independent Spent Fuel Storage Installation Project stage: RAI ML18058A0562018-02-23023 February 2018 Letter to J. Giddens Request for Additional Information Regarding Entergy Operations, Inc.S Decommissioning Funding Plan Update Project stage: RAI ML18058A6072018-02-23023 February 2018 HI-2177565, Rev 0, Holtec International & Eddy Lea Energy Alliance (Elea) Cis Facility - Decommissioning Cost Estimate and Funding Plan Project stage: Request 2018-01-10
[Table View] |
Text
HOL TEC INTERNATIONAL May 6. 2021 Yen-Ju Chen Division of Fuel Management Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 72-1032. Certificate of Compliance (CoC) No. 1032
Subject:
HJ-STORM FW Amendment 7 Request
Dear Ms. Chen:
1 Ioltec International herein submits a request to amend Certificate of Compliance (CoC) 72-1032 for the III-STORM fW MPC Storage System. The proposed changes include two additional MPC types, and the addition of the option to deploy the HJ-STORM FW system in an unventilated configuration.
The proposed changes do not reduce any or the safety metrics.
operational flexibility. or radiation protection features imbedded in the HI-STORM FW system.
In addition, the proposed changes include the reorganization of the CoC.
A summary of all of the proposed changes (SOPC ), with more detailed description of the changes, reason for the changes and justification for the changes, is provided in Attachment 1.
Attachments 2 through 4 contain changes for the current draft CoC and its appendices. and 6 provide the changed pages of the HI-STORM FW FSAR which support this LAR in proprietary and non-proprietary versions.
All proposed changes in Attachments 2 through 6 are provided in mark-up format to facilitate the Staffs review, with the exception of Supplement r. Since this supplement is completely new, no changes are marked. Note that the marked changes are only those associated with this LAR 1032-7.
Changes associated with previous amendments, up to and including HI-STORM FW Amendment 6, are included but not marked as changes, since that LAR request is under separate technical review.
Supporting proprietary documents, including a drawing and calculation packages, are included as Attachments 7 through 21. Attachments 22 through 24 contain the reorganized CoC and its appendices following RJRP-1-16-01, with Attachments 25 through 28 containing the supporting reorganization matrix and evaluations.
Since some attachments to this letter contain Holtec proprietary information, an affidavit requesting this information be withheld in accordance with 1 0CFR2.390 is included as Document ID 5018083 Page I of2
Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 HOLTEC INTERNATIONAL 9.
Telephone (856) 797-0900 Fax (856) 797-0909 Please contact me at (856) 797-0900 Extension 3931 if you have any questions or require any additional information.
Sincerely, Brian Seawright Licensing Engineer, Holtcc International cc:
John McKirgan (NRC)
Kim Manzione (Holtec)
Attachments: : HI-STORM FW Amendment 7 Summary of Proposed Changes : HI-STORM FW Amendment 7 Certificate of Compliance : HI-STORM FW Amendment 7 Certificate of Compliance, Appendix A : HI-STORM FW Amendment 7 Certificate of Compliance, Appendix B : HI-STORM FW FSAR Proposed Revision 9 revised pages (proprietary) : HI-STORM FW FSAR Proposed Revision 9 revised pages (non-proprietary) : Proposed Revised Licensing Drawings (proprietary) : Redundant Port Cover Closure Summary (proprietary) : Critical Dimension Report for MPC Baskets (proprietary) 0: Critical Dimension Report for HI-STORM FW Version UVH (proprietary) 1: Structural Calculation Package with Supplements 1, 43, 44, 45, 46, and 47 (proprietary) 2: HI-STORM FW Version UVH Non-Mechanistic Tipover Analysis (proprietary) 3: HI-STORM FW Version E Non-Mechanistic Tipover Analysis with Appendices C and D (proprietary) 4: HI-STORM FW Tornado Missile Analysis with Appendices I and J (proprietary) 5: Shielding Calculation Package (proprietary) 6: Criticality Calculation Package (proprietary) 7: Thermal Calculation Package (proprietary) 8: Thermal Evaluation of HI-STORM Version UVH (proprietary)
Document ID 5018083 Page 2 of3
Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 HOLTEC INTERNATIONAL Telephone (856) 797-0900 Fax (856) 797-0909 9: Thermal Evaluation of MPC-3 7P (proprietary) 0: Effective Thermal Properties of PWR Fuel (proprietary) 1: Effective Thermal Properties of PWR and BWR Fuel Assemblies of HI-STORM Version UVH (proprietary) 2: HI-STORM FW Amendment 7 Certificate of Compliance Reorganization 3: HI-STORM FW Amendment 7 Certificate of Compliance, Appendix A Reorganization 4: HI-STORM FW Amendment 7 Certificate of Compliance, Appendix B Reorganization 5: HI-STORM FW Amendment 7 Certificate of Compliance Reorganization Matrix 6: HI-STORM FW Amendment 7 Certificate of Compliance Reorganization Evaluation Form 7: HI-STORM FW Amendment 7 Certificate of Compliance, Appendix A Reorganization Evaluation Form 8: HJ-STORM FW Amendment 7 Certificate of Compliance, Appendix B Reorganization Evaluation Form 9: Affidavit in Accordance with 10 CFR 2.390 Document ID 50 I 8083 Page 3 of3