MONTHYEARML21033A3532021-01-14014 January 2021 Gns Gesellschaft Fur Nuklear-Service Mbh, Application for 10 CFR 71 Approval for the Castor geo69 Spent Nuclear Fuel Transportation Package Project stage: Request ML21092A1072021-05-0707 May 2021 Non-proprietary Enclosure - Request for Supplemental Information Model for Castor geo69 Project stage: Other ML21196A3742021-07-0202 July 2021 Response on Request for Supplemental Information for 10 CFR 71 Application of the Castor geo69 Spent Nuclear Fuel Transportation Package (Docket No. 71-9383; EPID No. L-2021-NEW-0002) Project stage: Supplement ML21245A2032021-08-25025 August 2021 Response on Request for Supplemental Information for 10 CFR 71 Application of the Castor Geo69 Spent Nuclear Fuel Transportation Package - Submission of Revised SAR Project stage: Supplement ML21245A2052021-08-25025 August 2021 Enclosure 5: 1014-SR-00001, Revision 1, Safety Analyses Report Type B(U)F Transport Package Castor geo69 Project stage: Other ML21245A2342021-08-25025 August 2021 Response on Request for Supplemental Information for 10 CFR 71 Application of the Castor Geo69 Spent Nuclear Fuel Transportation Package - Submission of Revised SAR Project stage: Request ML21245A2012021-08-25025 August 2021 Enclosure 3: Response on Request for Supplemental Information Dated May 7, 2021 Project stage: Supplement ML21308A3762021-12-21021 December 2021 Acceptance Letter and Early non-proprietary RAI for Castor geo69 Project stage: RAI ML22073A0092022-03-0202 March 2022 Gns - Response on Request for Additional Information for 10 CFR 71 Application of the Castor geo69 Spent Nuclear Fuel Transportation Package - Submission of Revised SAR Project stage: Request ML23046A1122023-03-16016 March 2023 Castor geo69 Transport Package RAI Letter Project stage: RAI ML23046A1102023-03-16016 March 2023 Enclosure 1 - Castor geo69 Transport Package - Non-Proprietary Project stage: Other ML23046A1092023-03-16016 March 2023 Castor geo69 Transport Package RAI Project stage: Request ML23257A0912023-08-25025 August 2023 Enclosure 3: Gns Gesellschaft Fur Nuklear-Service Mbh, Response on Request for Additional Information Dated March 16 2023 Model No. Castor geo69 Project stage: Request ML23257A0872023-08-30030 August 2023 Gns Gesellschaft Fur Nuklear-Service Mbh, Response on First Request for Additional Information and Submittal of Related Revised Documents Project stage: Request ML24038A2892024-02-22022 February 2024 Application for Certificate of Compliance for the Model No. Castor Geo69 Package - Second Request for Additional Information Project stage: RAI ML24038A2682024-02-22022 February 2024 Enclosure 1: Request for Additional Information Round 2 (Non-proprietary) Project stage: RAI ML24053A0232024-02-22022 February 2024 Notice of Meeting with Gns to Discuss the Recently Issued Request for Additional Information on the Castor Geo69 Round 2 Transportation Package Project stage: RAI ML24038A2662024-02-22022 February 2024 Castor Geo-69 Transportation Package, Certificate of Compliance No. 9383, Rev 3, Second Request for Additional Information Project stage: Request ML24073A0552024-03-0404 March 2024 Gns. 10 CFR71 Application of the Castor geo69 Spent Nuclear Fuel Transportation Package (Docket No. 71-9383; EPID No. L-2021-NEW-0002) and 10 CFR72 Application of the Castor geo69 Dry Storage System (Docket No. 72-1052; EPID No. L-2021-NEW- Project stage: Other ML24192A1822024-06-27027 June 2024 GNS-QAPD-001, Rev. 2, Quality Assurance Program Description (QAPD) Project stage: Other ML24192A1842024-06-28028 June 2024 Gns - Response on Second Request for Additional Information and Submittal of Related Revised Documents Project stage: Request ML24281A1762024-09-25025 September 2024 9/25/2024 Conference Call Summary - Supplemental Information to Proposed RAI Responses Related to the Criticality Safety Review of the Model No. Castor geo69 Transport and Storage Systems (Docket Nos. 71-9383 and 72-1052, Respectively) Project stage: Supplement ML24281A1742024-09-25025 September 2024 Enclosure 1, Non-Proprietary Information, Supplemental Information to Proposed RAI Responses Related to the Criticality Safety Review of the Model No. Castor geo69 Transport and Storage Systems Project stage: Supplement ML24285A1832024-09-26026 September 2024 Gns Gesellschaft Fur Nuklear-Service Mbh, Submittal of Revised SAR Sections Project stage: Other ML24305A2662024-11-15015 November 2024 Enclosure 1 - Certificate of Compliance 9383 Revision 0 Project stage: Other ML24305A2652024-11-15015 November 2024 Letter to D. Bussmann Revision No. 0 of Certificate of Compliance No. 9383 for the Model No. Castor Geo-69 Transportation Package Project stage: Other ML24305A2672024-11-15015 November 2024 Enclosure 2 - Safety Evaluation Report - Revision 0 to Certificate of Compliance 9383 Project stage: Approval 2023-08-25
[Table View] |
Text
OFFICIAL USE ONLYPROPRIETARY INFORMATION Dominik Bussmann Licensing Manager Gesellschaft für Nuklear-Service mbH Frohnhauser Strae 67 45127 Essen Germany
SUBJECT:
APPLICATION FOR CERTIFICATE OF COMPLIANCE FOR THE MODEL NO.
CASTOR GEO69 PACKAGE - FIRST REQUEST FOR ADDITIONAL INFORMATION
Dear Dominik Bussmann:
By letter dated July 10, 2020 (Agencywide Documents Access and Management System Accession No. (ML20198M431), Gesellschaft für Nuklear-Service mbH (GNS) requested approval of its quality assurance program. By letter dated January 14, 2021 (Agencywide Documents Access and Management System [ADAMS] Accession No. ML21033A353), as supplemented on July 2, 2021 (ML21196A374), August 25, 2021 (ML21245A234) and March 2, 2022 (ML22073A009), GNS submitted an application for a certificate of compliance for the Model No. CASTOR geo69 spent fuel transportation package.
In connection with our review, we need the information identified in the enclosures to this letter.
The request for additional information requested in this letter should be submitted in the form of revised safety analysis report pages. Please provide your response within 4 months from the date of this letter.
Documents transmitted herewith contain proprietary Information. When separated from the enclosure 2, this document is uncontrolled.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION March 16, 2023
D. Bussmann Please reference Docket No. 71-9383 and Enterprise Project Identifier (EPID) No. L-2021-NEW-0002 in future correspondence related to this request. The staff is available to meet to discuss your proposed responses. If you have any questions, I may be contacted at +1 (301) 415-6577 or via email at Bernard.White@nrc.gov.
Sincerely, Bernard H. White IV, Senior Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9383 EPID No. L-2021-NEW-0002
Enclosures:
1.
Non-proprietary RAI 2.
Proprietary RAI cc w/enclosure 1:
71sf9383all@listmgr.nrc.gov OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION Signed by White, Bernard on 03/16/23
ML23046A109; Ltr ML23046A112 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/IOB NMSS/DFM/MSB NAME BWhite WWheatley JGoodridge for MDavis OKhan DATE Feb 17, 2023 Feb 22, 2023 Mar 1, 2023 Feb 24, 2023 OFFICE NMSS/DFM/NARAB NRR/DEX/ESEB NMSS/DFM
/CTCFB NMSS/DFM/NARAB NAME EGoldfeiz SSamaddar CBajwa DForsyth DATE Feb 24, 2023 Mar 2, 2023 Feb 23, 2023 Feb 24, 2023 OFFICE NMSS/DFM/CTCFB NMSS/DFM/CTCFB NMSS/DFM/MSB NMSS/DFM/CTCFB NAME JBorowsky DMarcano TBoyce JPiotter DATE Feb 28, 2023 Mar 5, 2023 Mar 10, 2023 Mar 2, 2023 OFFICE NMSS/DFM/IOB NMSS/DFM/STLB NMSS/DFM/STLB NAME ARivera-Varona YDiaz-Sanabria BWhite DATE Mar 7, 2023 Mar 15, 2023 Mar 16, 2023