Letter Sequence Meeting |
|---|
EPID:L-2021-NEW-0006, Independent Spent Fuel Storage Installation - Request for a Temporary Exemption from 10 CFR 73, Appendix B, Section Le and 10 CFR 73.55(r) Annual Physical Requalification Requirement (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request
- Acceptance
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement, Supplement
Results
Other: ML21266A241, ML21266A242, ML22154A007, ML22291A074, ML22299A156, ML23124A283, ML23124A284, ML23124A285, ML23124A290, ML23124A291, ML23310A001, ML24016A006, ML24073A055, ML24093A068, ML24093A080, ML25142A336
|
MONTHYEARML21188A1592021-06-0707 June 2021 Gns Gesellschaft Fur Nuklear-Service Mbh, Application for 10 CFR 72 Approval for the Castor geo69 Spent Nuclear Fuel Dry Storage System - Safety Analyses Report Project stage: Request ML21188A1782021-06-0707 June 2021 Gns Gesellschaft Fur Nuklear-Service Mbh, Application for 10 CFR 72 Approval for the Castor geo69 Spent Nuclear Fuel Dry Storage System Project stage: Request ML21266A2422021-10-18018 October 2021 2. Enclosure 1: Request for Supplemental Information with Observations, Model No. Castor(R) geo69 Storage Cask Design (Non-Proprietary) Project stage: Other ML21266A2412021-10-18018 October 2021 1. Transmittal Letter Request for Supplemental Information, Model No. Castor(R) geo69 Storage Cask Design Project stage: Other ML21266A2402021-10-18018 October 2021 Request for Supplemental Information, Model No. Castor(R) geo69 Project stage: Request ML22046A0302022-02-0707 February 2022 Gns Gesellschaft Fur Nuklear-Service Mbh, Application for 10 CFR 72 Approval for the Castor geo69 Spent Nuclear Fuel Dry Storage System, Request for Technical Meeting Project stage: Meeting ML22061A1552022-02-0707 February 2022 Gns Proposed Agenda for Technical Meeting to Discuss the Application for the Model No. Castor Geo 69 Storage System Project stage: Meeting ML22046A0282022-02-0707 February 2022 Gns Gesellschaft Fur Nuklear-Service Mbh, 10 CFR72 Application of Castor geo69 Dry Storage System, Technical Meeting Project stage: Meeting ML22061A1562022-03-0202 March 2022 Notice of Partially Closed Meeting for the Castor geo69 Dry Storage System and Related Requests for Supplemental Information Project stage: Meeting ML22116A2282022-04-26026 April 2022 Summary of March 15, 2022, Meeting with Gesellschaft Fur Nuklear-Service Mbh to Discuss the Application and Requests for Supplemental Information for the Certificate of Compliance for the Model No. Castor GEO69 Storage System (Docket No. 72 Project stage: Meeting ML22154A0072022-06-0303 June 2022 Email Dated 6-3-22 from Dominik Bussmann Castor geo69, 2-month Delay-Revision of SAR for Storage Application Project stage: Other ML23124A2902022-10-11011 October 2022 1014-SR-00002, Revision 1, Safety Analyses Report Dry Storage System Castor geo69. Part 2 Project stage: Other ML22299A1562022-10-25025 October 2022 Email from Frank Schroeder (Gns) to Norma Garcia Santos (Nrc), Subject: QUERY-Status of Rsi Responses, Castor geo69 Storage System Project stage: Other ML22291A0742022-10-27027 October 2022 Approval of Gesellschaft Fur Nuklear-Service Mbh Request for Withholding Info Public Disclosure of the App for the Castor Geo69 Storage System, Amd 0 Doc NO.72-1052 Project stage: Other ML23012A0972022-12-21021 December 2022 Transmittal Letter and Enclosure 1 (Affidant), Gns Gesellschaft Fur Nuklear-Service Mbh - Response on Request for Supplemental Information for 10 CFR 72 Application of the Castor geo69 Dry Storage System - Submission of Revised SAR Project stage: Supplement ML23026A0892023-01-0404 January 2023 Enclosure 3: Gns Gesellschaft Fur Nuklear-Service Mbh, Response on Request for Supplemental Information Dated October 21 2021 Re Model No. Castor geo69 - Non-Proprietary Version Project stage: Supplement ML23026A0912023-01-12012 January 2023 Gns Gesellschaft Fur Nuklear-Service Mbh, Additional Response on Request for Supplemental Information for 10 CFR 72 Application of the Castor geo69 Dry Storage System - Submission of Revised SAR Project stage: Supplement ML23124A2852023-04-21021 April 2023 1014-SR-00002, Revision 0, Safety Analyses Report Dry Storage System Castor geo69. Part 1 Project stage: Other ML23124A2842023-04-21021 April 2023 Gns Gesellschaft Fur Nuklear-Service Mbh - 10 CFR 72 Application of the Castor geo69 Dry Storage System - Submission of Revised SAR Project stage: Other ML23124A2912023-04-21021 April 2023 1014-SR-00002, Revision 1, Safety Analyses Report Dry Storage System Castor geo69. Part 1 Project stage: Other ML23124A2832023-04-21021 April 2023 1014-SR-00002, Revision 0, Safety Analyses Report Dry Storage System Castor geo69. Part 2 Project stage: Other ML23216A0622023-08-0404 August 2023 Acceptance of Gesellschaft Fur Nuklear-Service Mbh Request for Amendment No. 0 to Certificate of Compliance No. 1052 for the Castor GE069 Storage System - Cost Activity Code 001028/Enterprise Project Identification Number L-2021-NEW-0006 Project stage: Acceptance Review ML23310A0012023-11-0606 November 2023 Email Dated 11-6-23 from D. Bussmann (Gns) to N. Garcia Santos (Nrc), Clarification - Castor geo69 Storage Application, Section 1.2, Figure 1.2-7: Schematic View (Left) and Cross Section (Right) of the Transfer Cask Project stage: Other ML23326A0112023-11-22022 November 2023 Email Dated 11-22-23 to D. Bussmann (Gns) from N. Garcia Santos (Nrc), Staggered RAIs Castor geo69 Storage Application - Materials, Structural, and Thermal Evaluations Project stage: RAI ML23334A0012023-11-27027 November 2023 Email Dated 11/27/2023 from Ngacia Santos (NRC) to Dbussmann (Gns) Regarding the Castor geo69 Storage Application RAIs and Possible Delay in the Review Project stage: RAI ML24012A1942024-01-12012 January 2024 Email Dated 1/12/24 from N. Garcia Santos (NRC) to D. Bussmann (Gns), Staggered Confinement RAIs for the Castor geo69 Storage Application (Docket No. 72-1052) Project stage: RAI ML24016A0062024-01-15015 January 2024 Email Dated 1/15/24 from D. Bussman (Gns) to N. Garcia Santos (Nrc), Staggered Confinement RAIs for the Castor geo69 Storage Application (Docket No. 72-1052) Project stage: Other ML24016A0082024-01-16016 January 2024 Attachment (Redacted) - Email Dated 1/15/24 from D. Bussman (Gns) to N. Garcia Santos (Nrc), Staggered RAIs for the Castor geo69 Storage Application - Confinement Evaluation (Docket No. 72-1052) (Public) Project stage: RAI ML24073A0552024-03-0404 March 2024 Gns. 10 CFR71 Application of the Castor geo69 Spent Nuclear Fuel Transportation Package (Docket No. 71-9383; EPID No. L-2021-NEW-0002) and 10 CFR72 Application of the Castor geo69 Dry Storage System (Docket No. 72-1052; EPID No. L-2021-NEW- Project stage: Other ML24093A0682024-04-0202 April 2024 Email Dated 4/2/24 from Ngarcia Santos (NRC) to Dbussmann (Gns), Subject: Summary Discussion - Status of the Castor geo69 Storage Application and Schedule Impacts Project stage: Other ML24093A0802024-04-0202 April 2024 Email Dated 4/2/24 from Dbussmann (Gns) to Ngarcia Santos (NRC) Regarding Verification of Redacted Proprietary Information from the Non-Proprietary Version of the Requests for Additonal Information for the Model No. Castor geo69 Storage Sys Project stage: Other ML24078A3712024-04-0505 April 2024 Transmittal Letter - Request for Additional Information for Review of the Certificate of Compliance for the Model No. Castor Geo69 Storage System - Cost Activity Code/Enterprise Project Identification Number 001028/ L-2021-NEW-0006 Project stage: RAI ML24078A3722024-04-0505 April 2024 Enclosure 1 (Non-Proprietary) - Request for Additional Information for Review of the Certificate of Compliance for the Model No. Castor Geo69 Storage System - Cost Activity Code/Enterprise Project Identification Number 001028/ L-2021-NEW-00 Project stage: RAI ML24250A0812024-08-30030 August 2024 Gns - Response on Request for Additional Information Dated April 5, 2024 Model No. Castor geo69 Docket 72-1052, EPID L-2021-NEW-0006 Project stage: Request ML24250A0822024-08-30030 August 2024 Gns - Response on Request for Additional Information for 10 CFR 72 Application of the Castor geo69 Dry Storage System - Submission of Revised SAR (Docket 72-1052; EPID L-2021-NEW-0006 Project stage: Request ML24281A1742024-09-25025 September 2024 Enclosure 1, Non-Proprietary Information, Supplemental Information to Proposed RAI Responses Related to the Criticality Safety Review of the Model No. Castor geo69 Transport and Storage Systems Project stage: Supplement ML24281A1762024-09-25025 September 2024 9/25/2024 Conference Call Summary - Supplemental Information to Proposed RAI Responses Related to the Criticality Safety Review of the Model No. Castor geo69 Transport and Storage Systems (Docket Nos. 71-9383 and 72-1052, Respectively) Project stage: Supplement ML24313A0762024-10-31031 October 2024 Gns - Response on Request for Additional Information for 10 CFR 72 Application of the Castor geo69 Dry Storage System - Submission of Final Response and Revised SAR Project stage: Request ML25142A3322025-03-18018 March 2025 Enclosure 1, Affidavit, Letter Dated 5/22/25 from Fkrattner and Dbussmann (Gns) to Dfm, Director (Nrc), Castor geo69 Dry Storage System-Submission of Response to Supplemental RAIs and Revised SAR Project stage: Supplement ML25142A3362025-05-21021 May 2025 Enclosure 5, Safety Analisys Report, Dry Storage System Castor geo69, Revision 3, Document No. 1014-SR-00002, Docket No. 72-1052 Project stage: Other ML25142A3342025-05-22022 May 2025 Enclosure 3, Responses, Letter Dated 5/22/25 from Fkrattner and Dbussmann (Gns) to Dfm, Director (Nrc), Castor geo69 Dry Storage System-Submission of Response to Supplemental RAIs and Revised SAR Project stage: Supplement ML25142A3312025-05-22022 May 2025 Letter Dated 5/22/25 from Fkrattner and Dbussmann (Gns) to Dfm, Director (Nrc), Application of the Castor geo69 Dry Storage System-Submission of Response to Supplemental Requests for Additional Information and Revised SAR (Ref. T1213-CO-000 Project stage: Supplement 2023-11-06
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 2, 2022 PARTIALLY CLOSED MEETING NOTICE Organization:
Gesellschaft für Nuklear-Service mbH (GNS)
Date:
March 15, 2022 9:00 a.m. - 12:00 p.m. (EST)
Location:
Videoconference
Purpose:
Discuss the application for approval for the CASTOR geo69 Dry Storage System (DSS) and requests for supplemental information (agenda enclosed).
Participants:
NRC/NMSS/DFM GNS Norma García Santos, et al.
Dominik Bussmann, et al.
Meeting Category:
This is an Observation Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned. The NRCs Policy Statement, Enhancing Public Participation on NRC Meetings, effective May 28, 2002, applies to this meeting. The policy statement may be found on the NRC website, www.nrc.gov, and contains information regarding visitors and security.
Because this is a virtual meeting, please inform the NRCs meeting contact of your intention to participate by March 10, 2022. This step will ensure that the link for the Teams videoconference meeting will be provided to attendees participating virtually or by telephone.
Contact:
Norma García Santos at Norma.GarciaSantos@nrc.gov Attendance at this meeting by other than those listed above should be made known by March 10, 2022, by email to the above contact with their full name, company/organization, and phone number.
Docket No.:
72-1052 EPID:
L-2021-NEW-0006
Enclosure:
Agenda
ML22061A156 ADAMS Package Accession No. ML22061A150 C=Without attachment/enclosure E=With attachment/enclosure N=No copy OFFICE DFM E
DFM N
NAME NGarcía Santos NGS WWheatley WW DATE 3/2/2022 3/02/2022
Enclosure AGENDA Meeting between GNS and the U.S. Nuclear Regulatory Commission March 15, 2022 9:00 a.m. - 12:00 p.m.
Public Session: 9:00 a.m. - 10:00 a.m.
- 1.
Opening remarks
- 2.
Introductions
- 3.
Project Overview Intend and Scope of 10 CFR Part 72 Application
- 4.
Applicable Regulations and Guidelines
- 5.
Comparison to Application Process in Germany
- 6.
Status of Application Closed Session (Proprietary): 10:15 a.m. - 12:00 p.m.
- 1.
CASTOR geo69 DSS
- a.
Definition of configuration for the DSS
- i.
Detailed description of the DSS and its components ii.
Detailed description of handling operations foreseen
- b.
Detailed description of the evaluation concept within the current application
- c.
Discussion regarding possibilities of acceptance of the application Evaluations to be performed for natural phenomena and normal, off-normal, and accident conditions
- 2.
CASTOR geo69 CLU and Implementation in 10 CFR Part 72 application
- a.
Design and functional overview
- i.
Detailed description of Transfer Cask and Transfer Lock ii.
Detailed description of handling operations
- b.
Boundary conditions to the reactor facility (including handling equipment) resulting from the CLU design (crane design, etc.)
- c.
Evaluations for off-normal conditions
- 3.
Further topics of RSI incl. observations previously not discussed (in 1. and 2.), if necessary.
- 4.
Discussion and agreement on further steps and project schedule.