ML22326A361

From kanterella
Jump to navigation Jump to search

Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System Request for Additional Information Batch 4 Letter
ML22326A361
Person / Time
Site: 07201032
Issue date: 12/07/2022
From: Yen-Ju Chen
Storage and Transportation Licensing Branch
To: Elisio D
Holtec
Shared Package
ML22326A358 List:
References
EPID L-2021-LLA-0053, CAC 001208
Download: ML22326A361 (3)


Text

OFFICIAL USE ONLY PROPRIETARY INFORMATION OFFICIAL USE ONLY PROPRIETARY INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Denise Elisio Holtec International Holtec Technology Campus 1 Holtec Blvd.

Camden, NJ 08104

SUBJECT:

AMENDMENT NO. 7 TO CERTIFICATE OF COMPLIANCE NO. 1032 FOR THE HI-STORM FLOOD/WIND MULTIPURPOSE CANISTER STORAGE SYSTEM -

REQUEST FOR ADDITIONAL INFORMATION BATCH 4

Dear Denise Elisio:

By a letter dated May 6, 2021 (Agencywide Documents Access and Management System

[ADAMS] Accession No. ML21126A266) and supplemented by letters dated October 15, 2021 (ML21288A521), February 17, 2022 (ML22048C221), July 11, 2022 (ML22192A215), July 13, 2022 (ML22194A954), July 29, 2022 (ML22210A145), September 15, 2022 (ML22258A250),

and October 3, 2022 (ML22276A281), Holtec International submitted to the U.S. Nuclear Regulatory Commission a request to amend the Certificate of Compliance No. 1032 for HI-STORM Flood/Wind Multipurpose Canister Storage System, as Amendment No. 7.

The staff reviewed the application and supplemental information, and determined additional information is needed to complete this review. The enclosed requests for additional information (RAI) contain one additional thermal RAI and four confinement RAIs that are related to your response to RAI 9-1 (ML22276A281). We request that you provide the responses to these RAIs within 30 days from the date of this letter. If you are unable to meet this deadline, please notify us in writing, within 2 weeks of receipt of this letter, of your new submittal date and the reasons for the delay.

A document transmitted by this letter contains Proprietary Information. When separated from Enclosure 2, this letter is decontrolled.December 7, 2022 OFFICIAL USE ONLY PROPRIETARY INFORMATION D. Elisio 2 OFFICIAL USE ONLY PROPRIETARY INFORMATIONPlease reference Docket No. 72-1032, CAC No. 001028, and EPID No. L-2021-LLA-0053 in future correspondence related to this licensing action. If you have any questions, please contact me at 301-415-1018.

Sincerely, Yen-Ju Chen, Sr. Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1032 CAC No.: 001208 EPID: L-2021-LLA-0053

Enclosures:

1. RAI
2. RAI proprietary Signed by Chen, Yen-Ju on 12/07/22

ML22326A358; Ltr ML22326A361

  • via email OFFICE NMSS/DFM/STLB NMSS/DFM/CTCFB NMSS/DFM/STLB NMSS/DFM/MSB NAME YChen YC FChang FCWWheatley WW LHowe LH DATE Nov 28, 2022 Nov 28, 2022 Nov 29, 2022 Nov 29, 2022 OFFICE NMSS/DFM/IOB NMSS/DFM/IOB NMSS/DFM/MSB* NMSS/DFM/CTCFB NAME JWoodfield JW ARivera-VaronaARTBoyce TB DMarcano DM DATE Nov 28, 2022 Dec 5, 2022 Dec 1, 2022 Dec 1, 2022 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NAME YDiaz-SanabriaYD YChen YC DATE Dec 6, 2022 Dec 7, 2022