L-24-190, Spent Fuel Storage Cask Registration

From kanterella
Jump to navigation Jump to search
Spent Fuel Storage Cask Registration
ML24240A046
Person / Time
Site: Perry, 07200069, 07201032  FirstEnergy icon.png
Issue date: 08/26/2024
From: Penfield R
Vistra Operations Company
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
L-24-190
Download: ML24240A046 (1)


Text

V IC D*..... - *.:,

Perry Nuclear Power Plant Rod Penfield S ite Vice President 1 O Center Road Perry, Ohio 44081 440-280-5382 724-462-0816 (cell)

August 26, 2024 L-24-190 10 CFR 72.212(b)(2)

Attention: Document Control Desk Director, Division of Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Perry Nuclear Power Plant Spent Fuel Storage Cask Registration Docket No. 50-440, License No. NPF-58 Docket No. 72-69

In accordance with the registration requirements of 10 CFR 72.212(b)(2), Vistra Operations Company LLC is providing the enclosed information to register three spent fuel storage casks at the Perry Nuclear Power Plant (PNPP) Independent Spent Fuel Storage Installation (ISFSI).

There are no regulatory commitments contained in this letter. If there are any questions, or if additional information is required, please contact Mr. Robert Oesterle, Manager - Regulatory Compliance, at (419) 321-7462.

Attachment:

Perry Nuclear Power Plant Spent Fuel Storage Cask Registration Information (2 pages)

cc: NRC Region III Administrator NRC Resident Inspector NRC Project Manager Branch Chief, Ohio Emergency Management Agency, State of Ohio (NRC Liaison)

Utility Radiological Safety Board

6 5 55 SIERRA DRIVE IRVING. T EXAS 75039 o 2 14 - 8 12-4600 V ISTRACORP.COM Attachment L-24-190

Perry Nuclear Power Plant Spent Fuel Storage Cask Registration Information Page 1 of 2

The following information is provided in accordance with 10 CFR 72.212(b)(2) for registration of these spent fuel storage casks at PNPP:

Licensee name: Vistra Operations Company LLC

Licensee Address: Perry Nuclear Power Plant 10CenterRoad Perry, Ohio 44081

Reactor License Number: NPF-58

Reactor Docket Number: 50-440

ISFSI Docket Number: 72-69

Contact Name and

Title:

William Partridge, PNPP Regulatory Compliance

Cask Certificate Number and Certificate of Compliance (COC)

Amendment Number: 72-1032; Amendment 5

Cask Model Number: HI-STORM FW, Version F

1st Cask Identification Number: MPC-0396-0438

Multi-Purpose Canister (MPC) Type 89, Standard Friction Stir Welded (FSW). Serial Number 0396

HI-STORM FW Version F, Overpack. Serial Number 0438

1st Cask Service Date: August 1, 2024

2nd Cask Identification Number: MPC-0397-0439

MPC Type 89, Standard FSW. Serial Number 0397

HI-STORM FW Version F, Overpack. Serial Number 0439

2nd Cask Service Date: August 8, 2024

Attachment L-24-190 Page 2 of 2

3rd Cask Identification Number: MPC-0398-0440

MPC Type 89, Standard FSW. Serial Number 0398

HI-STORM FW Version F, Overpack. Serial Number 0440

3rd Cask Service Date: August 15, 2024