ML23263B123

From kanterella
Jump to navigation Jump to search

HI-STORM 100 Amendment 16 Responses to Second Round Requests for Additional Information
ML23263B123
Person / Time
Site: Holtec
Issue date: 09/20/2023
From: Elisio D
Holtec
To: Yen-Ju Chen
Office of Nuclear Material Safety and Safeguards, Document Control Desk
Shared Package
ML23263B122 List:
References
EPID L-2021-LLA-0039, 5014969
Download: ML23263B123 (1)


Text

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 HOLTEC INTERNATIONAL Fax(856)797-0909 September 20, 2023 Yen Chen, Project Manager Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1014, Certificate of Compliance (CoC) No. 1014 EPID: L-202 l-LLA-0039

Subject:

HI-STORM I00 Amendment 16 Responses to Second Round Requests for Additional Information

Reference:

[I] "Amendment No. 16 To Certificate of Compliance No. 1014 for the HI-STORM I00 Multipurpose Canister Storage System - Request for Additional Information Second Round," letter from Y. Chen (NRC) to D. Elisio (Holtec) dated August 28, 2023. ADAMS Accession No. ML23230B158

Dear Ms. Chen:

By letter dated August 28, 2023 [l], NRC staff documented a Second Round Request for Additional Information to support review of HI-STORM 100 amendment request 1014-16. The response to the RAI is provided in Attachment 1. Changes to the FSAR as a result of these RAis are included in Attachment 2. Attachment 3 contains a proprietary document supporting the RAI responses.

Since Attachment 3 to this letter contains proprietary information, an affidavit requesting this information be withheld in accordance with 10CFR2.390 is included as Attachment 4.

Please contact me at (856) 797-0900 Extension 3326 if there are any questions or require any additional information.

Document ID 5014969 Page I of2

Holtec Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 HOLTEC INTERNATIONAL Fax (856) 797-0909 Sincerely1 Denise Elisio Licensing Engineer Hallee International cc: (via email)

Yoira Diaz-Sanabria (USNRC)

Tilda Liu (USNRC)

Kimberly Manzione (Holtec)

Attachments:

Attachment I: HI-STORM 100 Amendment 16 Second Round RAI Response (non-proprietary) : HI-STORM 100 FSAR Proposed Revision 21 G, changed pages (non-proprietary) : Appendix NN to Hl-2012702, HI STORM I 00 System Additional Shielding Calculations, Revision 19 (proprietary) : Affidavit in Accordance with IO CFR 2.390 Document ID 5014969 Page 2 of2