ML24143A075

From kanterella
Jump to navigation Jump to search
Re. Ginna Nuclear Power Plant and Independent Spent Fuel Storage Installation (ISFSI) Registration for Use of General License ISFSI Casks
ML24143A075
Person / Time
Site: Ginna, Holtec  Constellation icon.png
Issue date: 05/22/2024
From: Blankenship J
Constellation Energy Generation
To:
Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation, Document Control Desk
References
Download: ML24143A075 (1)


Text

Constellation James D. Blankenship s,te v,ce President R.E G,nna Clean Energy Center 1503 Lake Rel.

011tano. NY 14519 315-791*5205 Office Iarnes.blanl<ensh1pca constellat,on corn www.constellat,on.corn 10 CFR 72.212(b)(2)

May 22, 2024 ATTN: Document Control Desk Director, Division of Fuel Management, Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 RE. Ginna Nuclear Power Plant Renewed Facility Operating License No. DPR-18 NRC Docket No. 50-244 Independent Spent Fuel Storage Installation (ISFSI)

ISFSI Docket No. 72-67

Subject:

Registration for Use of General License ISFSI Casks In accordance with 10 CFR 72.212, "Conditions of general license issued under 72.210," paragraph (b)(2), Constellation Energy Generation, LLC (CEG) is registering with the NRC the use of four (4) casks under the general license to store spent fuel at the RE. Ginna Nuclear Power Plant ISFSI.

Registration is required to be submitted within 30 days. The four casks of the 2024 Campaign were placed into service with stored spent fuel as shown below:

Cask No.

In Service Date.

Registration Required By (218.0)-1714 04/29/2024 05/29/2024 (218.0)-1715 05/03/2024 06/02/2024 (218.0)-1713 05/10/2024 06/09/2024 (218.0)-1716 05/16/2024 06/15/2024 There are no regulatory commitments contained in this submittal. Should you have any other questions regarding this submittal, please contact Justin Knowles at (315) 791-3393.

Respectfully, lf0k~~

JDB/ejf

Attachment:

Cask Registration Information cc NRC Regional Administrator, Region I NRC Senior Resident Inspector, Ginna

Licensee Name:

Licensee Address:

Reactor License Number:

Reactor Docket Number:

ISFSI Docket Number:

Contact Person and

Title:

Cask ID Number l\\,'lulti-Purpose Canister Type_32, Serial No. 1023-956, HI-STORM 100S Serial No. (218.0)-1714 Multi-Purpose Canister Type 32, Serial No. 1023-957, HI-STORM 100S Serial No. (218.0)-1715 Multi-Purpose Canister Type 32, Serial No. 1023-958, HI-STORM 100S Serial No. (218.0)-1713 Multi-Purpose Canister Type 32, Serial No. 1023-959, HI-STORM 100S Serial No. (218.0)-1716 Attachment Cask Registration Information 10 CFR 72.212(b)(2) Required Information Cask Model Number HI-STORM 100S HI-STORM 100S HI-STORM 100S HI-STORM 100S Constellation Energy Generation R.E. Ginna Nuclear Power Plant, LLC 1503 Lake Road Ontario, NY 14519 Renewed DPR-18 50-244 72-67 Justin W. Knowles, Regulatory Assurance Manager Cask Certificate & Amendment In-Service Date Numbers

  • 1014, Renewed Amendment Number 13, Rev 0 Apr 29, 2024 1014, Renewed Amendment Number 13, Rev 0 May 3, 2024 1014, Renewed Amendment Number 13, Rev 0 May 10, 2024 1014, Renewed Amendment Number 13, Rev 0 May 16, 2024 Page 1 of 1