Letter from NRC to Duke Energy: Environmental Assessment and Finding of No Significant Impact Related to Exemption Request for NAC Magnastor Cask Loaded to Incorrect Helium Backfill Density
ML20192A328
Person / Time
Site: McGuire, 07201031, Mcguire  Duke Energy icon.png
Issue date: 07/10/2020
From: John Mckirgan
Storage and Transportation Licensing Branch
To: Teresa Ray
Duke Energy Carolinas
YJChen NMSS/DFM/STL 415.1018
Shared Package
ML20192A327 List:
References
CAC 001028, EPID L-2019-LLE-0024
Download: ML20192A328 (3)


Text

July 10, 2020 Mr. Thomas D. Ray, P.E.

Site Vice President McGuire Nuclear Station Duke Energy 12700 Hagers Ferry Road Huntersville, NC 28078

SUBJECT:

ENVIRONMENTAL ASSESSMENT AND FINDING OF NO SIGNIFICANT IMPACT RELATED TO EXEMPTION REQUEST FOR NAC MAGNASTOR CASK LOADED TO INCORRECT HELIUM BACKFILL DENSITY

Dear Mr. Ray:

Enclosed is a copy of the environmental assessment and Finding of No Significant Impact related to your application for an exemption dated September 12, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession Number No.

ML19270E395), and supplemented on February 3, 2020 (ADAMS Accession No. ML20052D934), and June 15, 2020 (ADAMS Accession No. ML20178A548), with respect to storing NAC MAGNASTOR Cask 0FCTKN045 at McGuire Nuclear Station Independent Spent Fuel Storage Installation (ISFSI) under Certificate of Compliance (CoC) No. 1031, Amendment No. 7.

The proposed action would allow Duke Energy to maintain MAGNASTOR Cask 0FCTKN045 at the McGuire Nuclear Station ISFSI in the storage condition where the helium density is above the range specified in CoC No. 1031, Amendment No. 7, TS 3.1.1. This would be permitted under exemption from the following requirements of Title 10 of the Code of Federal Regulations, Part 72, sections:

  • 10 CFR 72.212(b)(3), which states that the general licensee must Ensure that each cask used by the general licensee conforms to the terms, conditions, and specifications of a CoC or an amended CoC listed in § 72.214.
  • 10 CFR 72.212(b)(5)(i), which states that The cask, once loaded with spent fuel or once the changes authorized by an amended CoC have been applied, will conform to the terms, conditions, and specifications of a CoC or an amended CoC listed in § 72.214.

and

  • 10 CFR 72.212(b)(11), which states that The licensee shall comply with the terms, conditions, and specifications of the CoC and, for those casks to which the licensee has applied the changes of an amended CoC, the terms, conditions, and specifications of the amended CoC, including but not limited to, the requirements of any AMP put into effect as a condition of the NRC approval of a CoC renewal application in accordance with

§ 72.240.

T. Ray 2 The environmental assessment and Finding of No Significant Impact are being forwarded to the Office of the Federal Register for publication. If you have any questions, please contact me at (301) 415-5722, or Yen-Ju Chen of my staff, at (301) 415-1018.

Sincerely, John B. Digitally signed by John B.

McKirgan McKirgan Date: 2020.07.10 15:38:46 -04'00' John McKirgan, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket Nos.: 72-1031, 50-369, and 50-370 CAC No.: 001028 EPID No.: L-2019-LLE-0024

Enclosure:

Environmental Assessment

ML20192A327 (Pkg) ML2019A328 (Ltr)

  • concur via email OFFICE: DFM DFM OGC/NLO DFM NAME: YChen WWheatley* JMaltese* JMcKirgan DATE: 7/1/2020 6/24/2020 7/10/2020 7/10/2020