SUBJECT:
MCGUIRE NUCLEAR STATION - AGE RELATED DEGRADATION INSPECTION REPORT 05000369/2023010 AND 05000370/2023010
Dear Edward Pigott:
On September 14, 2023, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at McGuire Nuclear Station and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.
One finding of very low safety significance (Green) is documented in this report. This finding involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.
If you contest the violation or the significance or severity of the violation documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN:
Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement; and the NRC Resident Inspector at McGuire Nuclear Station.
October 13, 2023 This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, James B. Baptist, Chief Engineering Branch 1 Division of Reactor Safety Docket Nos. 05000369 and 05000370 License Nos. NPF-9 and NPF-17
Enclosure:
As stated
Inspection Report
Docket Numbers:
05000369 and 05000370
License Numbers:
Report Numbers:
05000369/2023010 and 05000370/2023010
Enterprise Identifier:
I-2023-010-0050
Licensee:
Duke Energy Carolinas, LLC
Facility:
McGuire Nuclear Station
Location:
Huntersville, NC
Inspection Dates:
August 28, 2023, to September 14, 2023
Inspectors:
S. Campbell, Senior Reactor Systems Engineer
J. Lizardi-Barreto, Reactor Inspector
G. Ottenberg, Senior Reactor Inspector
Approved By:
James B. Baptist, Chief
Engineering Branch 1
Division of Reactor Safety
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an Age Related Degradation Inspection at McGuire Nuclear Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations
Emergency Diesel Generator Fuel Oil and Lube Oil Hoses Installed With Less Than the Required Bend Radius Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000370,05000369/2023010-01 Open/Closed None (NPP)71111.21N.
The NRC identified a Green Finding and associated Non-cited Violation (NCV) of 10 CFR 50, Appendix B, Criterion XI, Test Control, for the licensee's failure to incorporate the hose bend radius acceptance limits as provided by the hose vendor into the test procedure used to verify the correct installation of the fuel oil and lube oil hoses on Emergency Diesel Generators (EDGs) 1A, 2A, 1B, and 2B.
Additional Tracking Items
None.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY
71111.21N.04 - Age-Related Degradation Age-Related Focused Engineering Inspection (section 03.01)
For each sample listed below, inspectors reviewed licensee activities credited to address age-related degradation to assess whether they were being performed using appropriate standards and procedures, assessed against appropriate acceptance criteria, and that maintenance was being performed at an appropriate interval. Inspectors assessed whether issues identified during licensee activities were being appropriately entered into and addressed by the station corrective action program, and whether periodic assessments of maintenance effectiveness and operating experience were being completed.
- (1) Emergency Diesel Generator (EDG) Fuel Oil Flexible Hoses (2)1B and 2B EDG Jacket Water Cooling (KD) Piping Flexible Coupling
- (3) Unit 2 VQ-1A and VQ-2B, Containment Air Release Diaphragm Valves
- (4) Westinghouse Contactor for 1EMXAF01E, Vital AC-DC System Charger No EVCA (5)1EPCBKETB12, Circuit Breaker for 1B Nuclear Service Water (RN) pump (6)1VP-7A and 1VP-6B, Lower Compartment Purge Inlet Valves
- (7) Unit 1 Hydrogen Igniters
- (8) Unit 2 MNS-EM-5390 Relay K2, Containment Spray Containment Pressure Control Alarm Module Relay (9)1NSPY5540, Power Supply for 1NSLP5540/ 1VELP5110/ 1VELP5450
- (10) Unit 2 Control Rod Drive Mechanism (CRDM) Thermal Sleeves (11)2A RN Pump Suction Piping (piping from 2A nuclear service water pond to RN pump suction)
- (12) Unit Auxiliary Transformer 2ATA
INSPECTION RESULTS
Emergency Diesel Generator Fuel Oil and Lube Oil Hoses Installed With Less Than the Required Bend Radius Cornerstone Significance Cross-Cutting Aspect Report Section Mitigating Systems Green NCV 05000370,05000369/2023010-01 Open/Closed None (NPP)71111.21N.0
The NRC identified a Green Finding and associated Non-cited Violation (NCV) of 10 CFR 50, Appendix B, Criterion XI, Test Control, for the licensee's failure to incorporate the hose bend radius acceptance limits as provided by the hose vendor into the test procedure used to verify the correct installation of the fuel oil and lube oil hoses on Emergency Diesel Generators (EDGs) 1A, 2A, 1B, and 2B.
Description:
During a walkdown of the EDGs, the inspectors identified that the flexible hoses installed on EDGs 1A, 2A, 1B and 2B used to deliver fuel oil and lube oil to the engines had bend radii smaller than the minimum bend radius published by the hose manufacturer, Eaton Aeroquip. The fuel oil injection pump suction/supply hoses (Catalog ID 864263 and Nordberg P/N 4425 3884) on the emergency diesel generators are Aeroquip FC300-10 material.
Aeroquip literature specifies a minimum bend radius of 5.5 inches for this hose material and diameter. The lube oil supply to the link shaft actuator is through a flexible hose (Catalog ID 864234 and Nordberg P/N 4425 4051) made from Aeroquip FC300-12 material. Aeroquip literature specifies a minimum bend radius of 6.5 inches for this hose material and diameter.
In response to the observation, the licensee initiated NCR 02486130, conducted an operability determination, and determined the EDGs remained operable. This determination was based, in part, on the licensee's prior evaluation to extend the hose replacement interval from six to 12 years. For this evaluation, the licensee removed a set of used hoses from the 1A diesel generator in 2020 and sent them for testing. The vendor lab tested new and used hoses to quantify the changes in mechanical properties of hoses that had been installed on 1A diesel for 5.6 years. While the hoses were not tested with the bend radius as installed on 1A EDG, the licensee determined the vendor testing supported the conclusion that current and near-term operability was not impacted by the configuration.
During the extent of condition review, the licensee determined 56 fuel oil hoses had a bend radius smaller than the manufacturer's acceptance limits, including 16 fuel oil hoses on EDGs 1A, 2A, and 2B and 8 fuel oil hoses on the left bank cylinders of EDG 1B. The licensee also determined that the lube oil hoses on EDGs 1A, 1B, and 2A had a smaller bend radius than specified by the hose manufacturer. There were no signs of leakage or damage to the fuel and lube oil hoses at the time of discovery, however, hoses with tighter bends may potentially experience abnormal wear and fatigue resulting in possible premature failure and downstream fluid pressures and/or flows inside the hose to be outside acceptable parameters.
In 2006, as part of the stations change in hose suppliers from original parts supplier, NAK Engineering, to the commercial hose manufacturer, Aeroquip, the licensee conducted a reverse engineering evaluation documented in Duke Energy Company Reverse Engineering Technical Document No. REDI 2020.00-00-0005, Aeroquip Fuel and Oil Hoses for MNS Diesels." The inspectors reviewed REDI 2020.00-00-0005 and test procedure PT/0/A/4350/030, "Nordberg Diesel Engine 6 Year Periodic Maintenance," Revisions 023, 027 and 029, which the licensee used to replace the hoses and accept the installation and determined that bend radius acceptance limits provided in REDI 2020.00-00-0005 were not translated into applicable sections of the procedure. The licensee previously installed the hoses under Work Orders -20378334-13, -20257780-02, -02102410-02, -20464037-01, 20464038-07, and 20464038-02, on the 1A EDG (June 2020 internal and external hose replacement), the 1B EDG (April 2019 internal and external hose replacement), the 2A EDG (April 2014 external hose replacement), the 2A EDG (July 2021 internal hose replacement),the 2B EDG (July 2022 external hose replacement), and the 2B EDG (March 2023 internal hose replacement), respectively.
Corrective Actions: The licensee initiated a condition report, conducted an operability determination, and determined the EDGs remained operable. Additionally, the licensee initiated Work Requests to replace the existing lube and fuel oil hoses on all four EDGs so the minimum bend radii is not exceeded.
Corrective Action References: NCR 02486130
Performance Assessment:
Performance Deficiency: The installation procedure for the EDG fuel oil and lube oil hoses (PT/0/A/4350/030) did not contain acceptance limits in document (Duke Energy Company Reverse Engineering Technical Document REDI Number 2020.00-00-0005, Aeroquip Fuel and Oil Hoses for MNS Diesels) for bend radius as provided by the hose vendor. The Duke Quality Assurance Program Document for Catawba, McGuire and Oconee, section D17.3.2.8, Test Control, required that:
Test procedures contain the following information or require this information be documented: 1) Requirements and acceptance limits contained in applicable design and vendor documents.
Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the Equipment Performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the inspectors determined the assurance of the reliability of the hose was impacted by the smaller than specified bend radius.
Significance: The inspectors assessed the significance of the finding using IMC 0609 Appendix A, The Significance Determination Process (SDP) for Findings At-Power. The inspectors assessed the significance of the finding using IMC 0609 Appendix A, The Significance Determination Process (SDP) for Findings At-Power. Exhibit 2 - Mitigating Systems Screening Questions, Item A. Mitigating SSCs and PRA Functionality (except Reactivity Control Systems), which specified that if the finding affected the design or qualification of a mitigating SSC, but it maintained its operability or PRA functionality then it screens to GREEN.
Cross-Cutting Aspect: Not Present Performance. No cross-cutting aspect was assigned to this finding because the inspectors determined the finding did not reflect present licensee performance.
Enforcement:
Violation: 10 CFR 50, Appendix B, Criterion XI, Test Control, requires, in part, that A test program shall be established to assure that all testing required to demonstrate that structures, systems, and components will perform satisfactorily in service is identified and performed in accordance with written test procedures which incorporate the requirements and acceptance limits contained in applicable design documents.
Contrary to the above, the test program for the EDG, which included PT/0/A/4350/030, did not incorporate requirements and acceptance limits contained in applicable design documents. Specifically, limits on the fuel oil and lube oil hose bend radius contained in applicable vendor documents contained in REDI Number 2020.00-00-0005 were not incorporated into PT/0/A/4350/030.
Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
- On September 14, 2023, the inspectors presented the Age Related Degradation Inspection results to Edward Pigott and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
Calculations
MCS-1240.03-00-
0001
McGuire Nuclear Station Plant Environmental
Qualification and Parameters
Revision 16
Corrective Action
Documents
Action Requests
(AR)
2314076, 2321224, 2351242, 2397076, 2449174,
2456604, 2486659, 2486660, 00916710, 01580026,
01699714, 01710737, 01903878, 02236247, 02236288,
247546, 02463772, 01582835, 01614118
various
EAR 02486324
Remove legacy NOTE on MCEE-165.00-07
09/11/2023
Dresser Style 38 couplings on 1B and 2B EDG do not
match parts manual
08/01/2023
Correct Degraded Voltage Relay EDB Records
08/09/2023
Emergency diesel generator flexible hose bend radius
challenges
09/08/2023
Corrective Action
Documents
Resulting from
Inspection
ARD NRC Inspection Observation on NDE-NE-ALL-6401
09/14/2023
54541862
Jacket Cooling Water Inlet Pipe
09/11/1967
91720162
Turbo Cooling Water Piping Assembly
05/05/1997
DW-26950014
3" Coupling
2/23/1961
MCM 1201.04-
0099.001
Diesel Fuel Oil Storage Tank
Revision 15
MCM 1205.02-
0095
Type 9220 Valve 150# A.N.S.I. - Class "2" W Bettis
- 732C-SR Actuator
Revision 1
MCM 1205.02-
0098
Cross Sectional Drawing 24" Type 9220 Valve W/ Bettis
2C-SR Actuator
Revision 1
MCM 1205.04-
0133.001
O/L 6" GRINNELL NUC. DIAPHRAGM VALVE W/#32101
AMO, ITEM 05B-219
10/04/2017
MCM 1314.01-
0098.001
2/15/2016
Drawings
MCM 1314.01-
24.001
Wiring Diagram SZ4 CFVNR Contactor with CPT 600V
Non Penetration, Essential Circuit
Revision 03
0000422389
REACTOR VESSEL HEAD CRDM THERMAL
SLEEVE/FUNNEL REPAIR
Revision 1
Replace H2 Glow Plugs
Revision 2
71111.21N.04
Engineering
Changes
M/CN, CGI, PQL2, Various, Hose, Aeroquip, JAS/MTB
2/13/2017
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
EDG Hose Replacement Evaluation
03/27/2023
Evaluation of Biobor JF as a Lubricity Enhancing
Supplemental Additive in Ultra Low Sulfur Diesel
11/13/2006
MD101156
Upgrade Engine Mounted FD Duplex Filters
06/12/2008
CGI010048
Commercial Grade Item Evaluation
Revision 1
MCM-1312.03-
213.001
Evaluation and Testing of ABB Circuit Breakers with
MOBIL Grease 28
Revision 0
PP12
Galvanic Susceptibility Inspection Package
Revision 0
PP13
Selective Leaching Inspection Package
Revision 1
PP20B
Buried Piping Integrity (NEI 09-14) Program Package
Revision 2
PP21
Service Water Piping Corrosion Program Package
Revision 5
Engineering
Evaluations
REDI No.
20.00-00-0005
Aerogui:g Fuel and Oil Hoses for MNS Diesels
01/17/2007
Justification for Using PRI-D Stability Additives
Fleet PM Template for Metal Clad Breakers
Revision 5
03/02/2015
00082160
PURCHASE ORDER FOR DIAPHRAGM, VALVE, 6",
EPDM, M-1
08/29/2023
00133063
Purchase Order for CAT ID 201632, contactor
07/07/2010
2007856
PM-2EQADE0001 : Perform 2-Year Inspection
10/20/2022
03037883
Purchase Order for Breaker, Circuit, Power, 4.16k, 1.2K,
N CAT ID: 0000445275
2/21/2016
03053480
Duke Energy Carolinas, LLC contract
08/16/2017
03094988
Duke Energy Carolinas, LLC contract
08/28/2023
2694
Laboratory Analysis Report
08/23/2022
203391
QC Inspection Report for HOSE, LUBE OIL PIPING,
DIESEL ENGINE, 33"
10/26/2021
3116927
Purchase Order for CAT ID 201632, contactor
09/08/2020
PMCH - Add EDG 2R PM scope to 6Y PM
06/02/2022
CGI010111
Commercial Grade Item Dedication for ExxonMobil Oil,
Mobil Oil
Revision 0
Miscellaneous
EHM.1
Maintenance Rule Function Scoping: Provides two trains
of H2 igniters to protect the containment structure from a
05/27/2015
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
sudden overpressure due to a hydrogen reaction by
igniting and burning off low concentrations of hydrogen
gas.
EPB-E-0
Basis Document for EP/1-2/A/5000/E-0 (Reactor Trip Or
Safety Injection)
Revision 3
EPRI NP-6406
_Technical Evaluation of Replacement Items (NCIG-11)
December
1989
EVAL-2021-MC-
EHM-00002181
(a)(1) Action Plan Approved, Actions in Progress
09/30/2020
MC, OS - 204.07
Emergency and SSF Diesel Fuel Oil Treatment
09/04/1987
MC-SFL
Surveillance Frequency List (SFL)
Revision 12
MCC -1535.00-
00-0033
McGuire PRA - Hydrogen Mitigation System
Revision 6
MCM 1205.02-
0161
Instruction Manual Type 9200 T-Ring Butterfly Valve
Bodies
2/29/1984
MCM 1301.00-
0077.001
Diesel Gen Engine Parts Manual
03/23/2023
MCM 1341.00-
0007.001
Tayco Hydrogen Igniter Equipment Test Reports
Revision
D01
MCM 1341.00-
0007.002
Tayco Hydrogen Igniters Similarity Test Report
Revision
D02
MCS-0165.EHM-
00-0001
Design Basis Specification for the Hydrogen Mitigation
System (EHM)
Revision 3
MCS-1205.04-1
Diaphragm-Type Valves to ASME Boiler & Pressure
Vessel Code Section III
10/21/1991
MCS-1301-00-00-
0001
Original Purchase Order Specification for 3500 KW, 4160
Volt Emergency Diesel Electric generating units
06/16/1969
MCS-1301.00-00-
0007
NORDBERG DIESEL REPLACEMENT PARTS
Revision 30
Assessment of Age-Related Degradation of Structures
and Passive Components for U.S. Nuclear Power Plants
August 2000
NUCLEAR REGULATORY COMMISSION INSPECTION
REPORT NO. 99901445/2014-201 AND NOTICE OF
NONCONFORMANCE
05/15/2014
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
MP-0-A-7300-066
Infrared Thermography and Motor Current Data
Acquisition
Revision 15
PO 03120292
Purchase Order for Flexible Hoses
11/20/2020
R-10730
Purchase Order Receiving Inspection Report for 3"
Dresser Coupling
VP.1
Maintenance Rule Function Scoping: Maintain two trains
of containment integrity.
05/27/2015
VP.4
Maintenance Rule Function Scoping: Maintain
containment closure for shutdown.
05/27/2015
VQ-Unit 2-LSS
Maintenance Rule PMG Details: Containment Air Release
& Addition-Unit 2-LSS-At Power
05/27/2015
VQ.1
Maintenance Rule Function Scoping: Provide two trains
of containment isolation
05/27/2015
VQ.2
Maintenance Rule Function Scoping: Maintain
containment pressure (-0.3 to +0.3) during normal
operation such that a plant level event per AD-EG-ALL-
210 cannot occur
05/27/2015
VQ.3
Maintenance Rule Function Scoping: Maintain
containment closure for shutdown.
05/27/2015
48-500-10H
Power Transformer Maintenance
May 29,
2003
AD-EG-ALL-1103
Procurement Engineering Products
Revision 7
AD-EG-ALL-1132
Preparation and Control of Engineering Changes
Revision 25
AD-EG-ALL-1216
SURVEILLANCE FREQUENCY CONTROL PROGRAM
Revision 3
AD-EG-ALL-1650
License Renewal Aging Management
Revision 5
AD-EG-ALL-1670
VENDOR TECHNICAL INFORMATION PROGRAM
2/04/2021
AD-EG-MNS-
1650
MNS License Renewal Implementation
Revision 0
CP/0/A/8600/027
Sampling Diesel Fuel Oil Tanks
March 7,
2008
CSD-EG-MNS-
1650-16
MNS License Renewal Containment Inservice Inspection
Plan Basis Document
Revision 0
Procedures
CSD-EG-MNS-
1650-17
MNS License Renewal Containment Leak Rate Testing
Program Basis Document
Revision 0
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
ET-1215
Rochester Instrument Systems, Dual Input
Voltage/Current Alarm with Fixed Deadband
Revision A
MCC -1535.00-
00-0006
PRA RISK SIGNIFICANT SSCS FOR THE
MAINTENANCE RULE
Revision 5
MCM 1306.00-
0012.001
Transformer General Electric Instruction Manual
5-25-2010
MCM 1314.01-
0166.001
Instructions for A200 Size 3 or 4, 3 Pole Motor Controller
01/31/2019
MSS SP-100-
2015
Qualification Requirements for Elastomer Diaphragms for
Nuclear Service Diaphragm Valves
NPP-311
Receipt, Inspection, and Control of QA Condition
Materials, Parts And Components Except Nuclear Fuel
Revision 0
NSD-319
Vendor Technical Information Program
Revision 2
NSD-319
Vendor Technical Information Program Superseded by
AD-EG-ALL-1670, Vendor Technical Information Program
Implementation
Revision 5
PT/0/A/4350/021
Nordberg Diesel Engine 2 Year Periodic Maintenance
Revision 44
PT/0/A/4350/030
Nordberg Diesel Engine 6 Year Periodic Maintenance
Revision 29
PT/1/A/4200/001
N
VP VALVE LEAK RATE TEST
Revision 24
PWROG-16003-P
Evaluation of Potential Thermal Sleeve Flange Wear
Revision 2
PWROG-21026-P
CRDM Latch Assembly Wear - CAD Study and Decision
Tree
Revision 0
2386909-05
Maintenance Rule Program Self-Assessment
06/23/2021
2447981-05
Maintenance Rule Program Self-Assessment
10/27/2022
AS 1902585
McGuire Nuclear Station Maintenance Rule (a)(3)
Assessment
11/20/2014
AS 1971272
McGuire Maintenance Rule (a)(3) Periodic Assessment
06/23/2016
AS 2189797
Maintenance Rule Periodic Assessment For Maintenance
Rule Implementation
11/17/2017
PMCH 02481203
NRC Age-Related Degradation inspection self-
assessment (AR 2479221),
07/31/2023
QRPT 2291978
MNS Maintenance Rule (a)(3) Assessment
08/01/2019
Self-
Assessments
QRPT 2386909
MNS Maintenance Rule (a)(3) Periodic Assessment
08/23/2021
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
QRPT 2447981
MNS Maintenance Rule (a)(3) Assessment
10/27/2022
Work Orders
Work Orders
(WO)
WO-20257780-02, WO-02030303-25, WO-20464038-02,
WO-20378334, WO-20464038-07, WO-1839977-02, WO- 1839977-03, WO-1839977-07, WO-20085026-03, WO- 20085026-04, WO-20085026-05, WO-20085026-11, WO- 20184120-01, WO-20191609-01, WO-20287101-03, WO- 287101-04, WO-20287101-05, WO-20287101-11, WO- 287101-13, WO-20296864-01, WO-20296864-05, WO- 296864-06, WO-20296864-07, WO-20296864-10, WO- 296864-11, WO-20296864-12, WO-2131159-01, WO- 2131159-02, WO-2131159-03, WO-2131159-04, WO- 2131159-05, WO-2131159-06, WO-2131159-07, WO- 2131159-08, WO-20215944-01, WO-20228599-01, WO- 228599-02, WO-20258358-01, WO-20258358-02, WO- 258358-03, WO-20258358-04, WO-20258358-05, WO- 258358-06, WO-20258358-07, WO-20258358-08, WO- 258358-09, WO-20258358-10, WO-20258358-11, WO- 20399612-01, WO-20439620-01, WO-20439620-02,
WO-20439620-03, WO-20439620-04, WO-20439620-05,
WO-20439620-06, WO-20439620-07, WO-20439620-08,
WO-20439620-09, WO-20439620-10, WO-20439620-11,
WO-20439620-12, WO-02043847-01, WO-20179859-03,
WO-20157548-01, WO-2043847-02, WO-20179859-04,
WO-20367100, WO-20112178-01, WO-20257762-01,
WO-20366575-01, WO-20476892-01, WO-20215071-01,
WO-20219932-01, WO-20233880-01, WO-20238783-01,
WO-20257039-01, WO-20259283-01, WO-20276239-01,
WO-20277951-01, WO-20295501-01, WO-20298391-01,
WO-20312609-01, WO-20314742-01, WO-20327298-01,
WO-20329603-01, WO-20347151-01, WO-20500762-01,
WO-20504388-01, WO-20519636-01, WO-20524561-01,
WO-20534858-01, WO-20539990-01, WO-20552480-01,
WO-20557497-01, WO-20568900-01, WO-20572411-01,
WO-20588630-01, WO-20589674-01, WO-20464037,
Inspection
Procedure
Type
Designation
Description or Title
Revision or
Date
WO-2102410, WO-98452681, WO-513382, WO- 2097733, WO-20242840, WO-20277294, WO- 20319657, WO-20369629, WO-20462964, WO- 20469994-02, WO-20474480-02, WO-20482927-02, WO- 20488504-02, WO-20500180, WO-20544990-02, WO- 20549968-02, WO-20555435-02, WO-20591134, WO- 20597411-02, WO-20543600, WO-20580031, WO- 20324616, WO-20400717, WO-20202048, WO- 284681, WO-20355986, WO-20428877, WO- 20496394, WO-20563582