Letter Sequence RAI |
|---|
EPID:L-2023-LLA-0105, Independent Spent Fuel Storage Installation - Request for a Temporary Exemption from 10 CFR 73, Appendix B, Section Le and 10 CFR 73.55(r) Annual Physical Requalification Requirement (Approved, Closed) EPID:L-2024-LLA-0158, Submittal of an Amendment Request for the NAC International Magnastor Cask System Amendment No. 14 (Open) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, ... further results|Request]]
- Acceptance
- Supplement, Supplement
Results
Other: ML25042A638, ML25042A640, ML25042A641, ML25042A642, ML25042A643, ML25042A644, ML25042A645, ML25042A646, ML25042A647, ML25042A648, ML25042A649, ML25042A650, ML25042A651, ML25042A652, ML25042A653, ML25042A654, ML25042A655, ML25042A656, ML25042A657, ML25042A658, ML25042A659, ML25042A660, ML25042A661, ML25042A662, ML25042A663, ML25042A664, ML25042A665, ML25042A666, ML25042A667, ML25042A668, ML25042A669, ML25042A670, ML25042A671, ML25042A672, ML25042A673, ML25042A674, ML25042A675, ML25042A676, ML25042A677, ML25042A678, ML25042A679, ML25042A680, ML25042A681, ML25042A682, ML25042A683, ML25042A684
|
MONTHYEARBVY 17-041, Supplement to Exemption Request from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 to Support the Dry Fuel Loading Campaign2017-12-0707 December 2017 Supplement to Exemption Request from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 to Support the Dry Fuel Loading Campaign Project stage: Supplement ML17249A1572018-01-11011 January 2018, 16 January 2018 Package: Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Request ML17249A1592018-01-16016 January 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station ISFSI Environmental Assessment and Finding of No Significant Impact Related to Issuance of Exemption to Allow a New Loading Pattern and Loading Fuel Cooled for at Least 2 Years Project stage: Approval ML17298A1352018-02-0202 February 2018 Safety Evaluation Report (Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML17298A1332018-02-0202 February 2018 Package: Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Request ML17298A1342018-02-0202 February 2018 Letter to C. C. Chappell Vermont Yankee Nuclear Power Station Independent Spent Fuel Storage Installation, Issuance of Exemption (CAC No.: 001028, Docket Nos. 50-271, 72-59, and 72-1014; EPID L-2017-LLE-0005) Project stage: Approval ML18031A2212018-02-0606 February 2018, 8 February 2018 Package: Issuance of Renewed Materials License No. SNM-2507 for the North Anna Power Station Independent Spent Fuel Storage Installation (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008) Project stage: Request ML18057A2162018-02-23023 February 2018 Package: Request for Additional Information for Review of Duke Energy'S Decommissioning Funding Plan Update Project stage: Request ML18058A0552018-02-23023 February 2018 Package: Request for Additional Information Regarding Entergy Operations, Inc.'S Decommissioning Funding Plan Update Project stage: Request ML18206A5952018-07-19019 July 2018 Interim Storage Partners, LLC - Submittal of License Application Revision 2, and Request to Restart Review of Application for Approval of the WCS Cisf Project stage: Request ML18267A2142018-08-29029 August 2018, 25 September 2018 Package: Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) Project stage: Request ML19126A0682019-04-0303 April 2019, 6 May 2019 Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: Request ML19112A0712019-04-17017 April 2019 Package: Acceptance Review of Holtec International HI-STORM Umax Application for Certificate If Compliance No. 1040, Amendment No. 4 (CAC No. 001028, Dkt No. 72-1040, EPID: L-2018-LLA-0275) Request for Supplemental Information Project stage: Request ML19161A3282019-06-0707 June 2019 Package: Environmental Assessment and Finding of No Significant Impact for First Energy Nuclear Operating Company'S Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72.30(B) and 72.30(C) for Beaver Valley ISFSI Project stage: Request ML19162A0292019-06-0707 June 2019 Package: Environmental Assessment and Finding of No Significant Impact for Firstenergy Nuclear Operating Company'S Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72.30(B) and 72.30(C) for Perry ISFSI Project stage: Request ML19310F7442019-11-0404 November 2019 CoC 1029 Renewal Rsi Transmittal Letter Package Project stage: Request ML19312B5142019-11-0808 November 2019 Notice of Partially Closed Meeting with Westinghouse Electric Co. LLC to Discuss the Submittal of the Application for Amendment 5 of the Storage Certificate of Compliance No. 1026 for the Fuelsolutions Spent Fuel Management System Project stage: Meeting ML20002A2792019-11-20020 November 2019, 2 January 2020 Meeting Summary of 11-20-2019 Meeting on CoC 1026 Renewal Project stage: Request ML19338E2412019-12-0202 December 2019 Westinghouse - Sentry Dry Fuel Storage System Pre-Submittal Presentation Materials Project stage: Request ML20015A3142020-01-14014 January 2020 Package: Exemption Request McGuire Nuclear Facility Project stage: Request ML20049A0812020-01-31031 January 2020 Holtec International - HI-STORM 100 Storage CoC Renewal Application Project stage: Request ML20034E9872020-02-11011 February 2020 Meeting Summary - Meeting with Westinghouse Electric Company, LLC, Pre-Application Amendment No. 5 of Storage CoC No. 1026 for the Fuelsolutions Spent Fuel Management System, November 21, 2019 Project stage: Meeting ML20150A2672020-05-28028 May 2020 CoC 1029 RAI Transmittal Letter Package Project stage: Request ML20153A7682020-06-0101 June 2020, 11 June 2020 International, Submittal of Responses to NRC RAIs on the Renewal of the HI-STAR 100 Storage CoC Project stage: Request ML20198M6382020-07-16016 July 2020, 21 October 2020 International, Supplemental Archeological Information Project stage: Request ML20280A2892020-10-0606 October 2020 CoC 1021 (TN-32) Renewal - RAI Project stage: Request ML20150A2622020-11-23023 November 2020 Environmental Assessment and Finding of No Significant Impact for Entergy Operations, Inc., Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72.30(b) and (C) for Grand Gulf ISFSI Project stage: Request ML20349A2062021-01-0404 January 2021 CoC 1040 Amendment 4 - Issuance Letter with Final CoC, TS and SER Project stage: Request ML21067A1642021-04-13013 April 2021, 6 August 2021 CoC 1029 Renewal Package Project stage: Request ML21125A1032021-06-0707 June 2021, 3 August 2021 User Need Memo Package for CoC 1042 Amendment 2 Project stage: Request ML21168A2572021-06-17017 June 2021 GE-Hitachi Nuclear Energy Americas, LLC, Updated Morris Operation Decommissioning Funding Plan Project stage: Request ML21176A1082021-06-29029 June 2021 Moe Fqt Topical Report Rsi Project stage: Request ML21231A1542021-06-30030 June 2021, 10 August 2021 NAC International, Inc. - Responses to the Nuclear Regulatory Commissions (NRC) Request for Additional Information for the Request to Renew the NRC Certificate of Compliance No. 1025 for the NAC-MPC Cask System Project stage: Request ML21211A6082021-07-30030 July 2021 HI-STORM FW Amendment 8 Request Project stage: Request ML21223A0452021-08-10010 August 2021, 11 August 2021 HI-STORM 100 Amendment 16 Responses to Requests for Supplemental Information Project stage: Request ML21244A2952021-09-15015 September 2021 CoC 1042 Eos A2 Issuance Package to Tn Project stage: Request ML21281A0732021-10-28028 October 2021 Eos A3 - RAI Project stage: Request ML21341B3602021-12-0808 December 2021 Letter to K. Manzione - Audit Plan for NRC Audit of Holtecs Responses to Second RAI - HI-STORE CISF License Application Project stage: Request ML21334A5082021-12-21021 December 2021 CoC 1015 RAI Transmittal Letter Package Project stage: Request ML22028A3712022-01-28028 January 2022 International, HI-STORM 100 Amendment 16 Additional Information on Graded Approach Project stage: Request ML22098A2332022-04-14014 April 2022, 31 January 2023 Rulemaking for the Renewal of CoC No. 1014, HI-STORM 100 Cask System Project stage: Request ML22168A0172022-06-14014 June 2022, 17 June 2022, 30 June 2022 Certificate of Compliance 1042, NUHOMS Eos System Updated Final Safety Analysis Report (Ufsar), Revision 4 Project stage: Request ML22122A1982022-06-22022 June 2022, 23 June 2022 CoC 1014 Amendment No.18 Project stage: Request 2020-02-11
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Heath Baldner, Director, Licensing Engineering NAC International, Inc.
2 Sun Court, Suite 220 Peachtree Corners, GA 30092
SUBJECT:
APPLICATION FOR AMENDMENT NO. 14 TO THE MODEL NO.
MAGNASTOR STORAGE CASK - REQUEST FOR ADDITIONAL INFORMATION
Dear Heath Baldner:
By letter dated July 24, 2023 (Agencywide Documents Access and Management System
[ADAMS] Accession No. ML23208A062), you submitted an application for Amendment No. 14 and Revisions to Amendment Nos. 0 through 12 of the Certificate of Compliance (CoC)
No. 1031 for the NAC MAGNASTOR System.
The enclosed request for additional information identifies information needed by the U.S. Nuclear Regulatory Commission (NRC) staff in connection with its review of these applications. Each question describes information needed by the staff for it to complete its review of the application and to determine whether the applicant has demonstrated compliance with regulatory requirements.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 2, Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room (PDR) or from the Publicly Available Records component of the NRCs ADAMS. ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html. The PDR is open by appointment. To make an appointment to visit the PDR, please send an email to PDR.Resource@nrc.gov or call 1-800-397-4209 or 301-415-4737, between 8 a.m. and 4 p.m. eastern time (ET), Monday through Friday, except Federal holidays.
May 7, 2024
H. Baldner 2
In order to complete our technical review on schedule, your response should be provided within 60 days from the date of this letter. If you have any questions regarding this matter, I may be contacted at (301) 415-5196.
Sincerely, Nishka Devaser, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1031 EPID L-2023-LLA-0105 and L-2024-LLA-0158
Enclosure:
Request for Additional Information Signed by Devaser, Nishka on 05/07/24
- ML24120A036 OFFICE NMSS/DFM/STLB NMSS/DFM/MSB NMSS/DFM/STLB NAME NDevaser SSamaddar WWheatley DATE 4/29/2024 4/30/2024 5/1/2024 OFFICE NMSS/DFM/MSB NMSS/DFM/STLB NMSS/DFM/STLB NAME TBoyce YDiaz-Sanabria NDevaser DATE 5/1/2024 5/7/2024 5/7/2024
Enclosure UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Request for Additional Information Docket No. 72-1031 Certificate of Compliance No. 1031 Model No. MAGNASTOR Storage System Amendment No. 14 By letter dated July 24, 2023 (Agencywide Documents Access and Management System Accession No. ML23208A062), you submitted an application for Amendment No. 14 and Revisions to Amendment Nos. 0 through 12 of the Certificate of Compliance (CoC) No. 1031 for the NAC MAGNASTOR System. You requested to (1) assess changes to the CoC and technical specifications resulting from the error corrected in the non-mechanistic tip-over accident condition, (2) revise technical specification definitions to provide clarification regarding the applicability of the pressurized-water reactor grid damage allowance to be consistent with fuel rod evaluations, and (3) revise limiting condition for operation 3.1.2 to provide system users clarification on inlet and outlet vent blockage and surveillance requirements.
The questions below describe information needed by the staff for it to complete its review of the application and to determine whether the applicant has demonstrated compliance with regulatory requirements.
Chapter 3:
Structural Evaluation RAI 3-1.
Using dimensional and mass information about each cask model and the associated fuel assemblies included in the CoC, show that the G-values used in the ANSYS tip over analysis is bounding for all the configurations of the dry cask storage systems.
The non-mechanistic tip over analysis conserves the potential energy generated by the change in the position of the center of gravity of the cask into rotational kinetic energy during a tip over. The kinetic energy represented by an acceleration time-history (ATH) is converted to a response spectrum for a static analysis in ANSYS. A static load on the fuel rod is then defined using a dynamic load factor (DLF), which represents the dynamic response characteristics of the fuel rod. This static load results in the computed stresses in the rod.
This information is required under 10 CFR Part 72, for use in the evaluation of the fuel rods integrity during a non-mechanistic tip over scenario.
RAI 3-2.
Explain if the assumptions made in Calc. No.: 71160-2049 Rev. 1, Section 5.0 Assumptions (referenced in the safety analysis report are new assumptions or if they are the same as in the original calculation, where the incorrect diameter was used. If different, how do these identified assumptions effect the presented stress results.
The assumptions in the design are a part of the analysis input as much as the other physical design inputs. The staff wants to understand the impact of the assumptions on the results.
2 Since the initial analysis underestimated the stress in the rod the staff wants to be assured that the revised stress results are a result of the change in the design input or a combination of the design assumptions and design input.
This information is required under 10 CFR Part 72, for use in the evaluation of the fuel rods integrity during a non-mechanistic tip over scenario.