ML23328A005: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:}}
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 5, 2023 Kimberly Manzione, Director of Licensing - NMSS Projects Holtec International Krishna P. Singh Technology Campus One Holtec Boulevard Camden, NJ 08104
 
==SUBJECT:==
ISSUANCE OF RENEWED CERTIFICATE OF COMPLIANCE NO. 1014, AMENDMENT NO. 17 FOR THE HI-STORM 100 CASK SYSTEM (CAC/EPID NOS. 001028/L-2021-LLA-0140)
 
==Dear Kimberly Manzione:==
 
By a {{letter dated|date=July 30, 2021|text=letter dated July 30, 2021}} (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21211A603), Holtec International (Holtec), submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 72 for an amendment to renewed Certificate of Compliance (CoC) No. 1014 for the HI-STORM 100 Cask System. Amendment No. 17 updates the description of the system in the CoC to indicate that only the portions of multi-purpose canister components that come into contact with the pool water need to be made of stainless steel or aluminum. Amendment No. 17 also includes minor editorial and formatting changes to the technical specifications.
As stated in the Federal Register (88 FR 74019, October 30, 2023), the effective date of renewed CoC No. 1014, Amendment No. 17 is January 16, 2024. Attached are renewed CoC No. 1014, Amendment No. 17, and the corresponding technical specifications and final safety evaluation report. This amended certificate constitutes the approval and conditions for the use of the HI-STORM 100 Cask System for the storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210.
 
K. Manzione                                      2 If you have any questions regarding this certificate, please contact Kristina Banovac at (301) 415-7116 or Kristina.Banovac@nrc.gov.
Sincerely, Signed by Diaz-Sanabria, Yoira on 12/05/23 Yoira K. Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1014 CAC/EPID Nos.: 001028/ L-2021-LLA-0140
 
==Enclosures:==
: 1. CoC 1014, A17, CoC
: 2. CoC 1014, A17, Appendix A
: 3. CoC 1014, A17, Appendix B
: 4. CoC 1014, A17, Appendix A-100U
: 5. CoC 1014, A17, Appendix B-100U
: 6. CoC 1014, A17, Appendix C
: 7. CoC 1014, A17, Appendix D
: 8. CoC 1014, A17, Final Safety Evaluation Report
 
ML23328A004 (PKG), ML23328A005 (LTR), ML23328A027 (SER)
OFFICE NMSS/DFM/STLB            NMSS/DFM/STLB    NMSS/DFM/STLB NAME      KBanovac              WWheatley        YDiaz-Sanabria DATE      11/27/2023            11/29/2023      12/1/2023 OFFICE NMSS/DFM/STLB            NMSS/DFM/STLB NAME      KBanovac              YDiaz-Sanabria DATE      12/5/2023            12/5/2023}}

Latest revision as of 23:04, 11 December 2023

Issuance of Renewed Certificate of Compliance No. 1014, Amendment No. 17 for the Hi-Storm 100 Cask System (Cac/Epid 001028/L-2021-LLA-0140)
ML23328A005
Person / Time
Site: Holtec
Issue date: 12/05/2023
From: Yoira Diaz-Sanabria
Storage and Transportation Licensing Branch
To: Manzione K
Holtec
Banovac, K 415-7116
Shared Package
ML23328A004 List:
References
EPID L-2021-LLA-0140, CAC 001028
Download: ML23328A005 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 5, 2023 Kimberly Manzione, Director of Licensing - NMSS Projects Holtec International Krishna P. Singh Technology Campus One Holtec Boulevard Camden, NJ 08104

SUBJECT:

ISSUANCE OF RENEWED CERTIFICATE OF COMPLIANCE NO. 1014, AMENDMENT NO. 17 FOR THE HI-STORM 100 CASK SYSTEM (CAC/EPID NOS. 001028/L-2021-LLA-0140)

Dear Kimberly Manzione:

By a letter dated July 30, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21211A603), Holtec International (Holtec), submitted an application in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 72 for an amendment to renewed Certificate of Compliance (CoC) No. 1014 for the HI-STORM 100 Cask System. Amendment No. 17 updates the description of the system in the CoC to indicate that only the portions of multi-purpose canister components that come into contact with the pool water need to be made of stainless steel or aluminum. Amendment No. 17 also includes minor editorial and formatting changes to the technical specifications.

As stated in the Federal Register (88 FR 74019, October 30, 2023), the effective date of renewed CoC No. 1014, Amendment No. 17 is January 16, 2024. Attached are renewed CoC No. 1014, Amendment No. 17, and the corresponding technical specifications and final safety evaluation report. This amended certificate constitutes the approval and conditions for the use of the HI-STORM 100 Cask System for the storage of spent nuclear fuel under the general licensing provisions of 10 CFR 72.210.

K. Manzione 2 If you have any questions regarding this certificate, please contact Kristina Banovac at (301) 415-7116 or Kristina.Banovac@nrc.gov.

Sincerely, Signed by Diaz-Sanabria, Yoira on 12/05/23 Yoira K. Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1014 CAC/EPID Nos.: 001028/ L-2021-LLA-0140

Enclosures:

1. CoC 1014, A17, CoC
2. CoC 1014, A17, Appendix A
3. CoC 1014, A17, Appendix B
4. CoC 1014, A17, Appendix A-100U
5. CoC 1014, A17, Appendix B-100U
6. CoC 1014, A17, Appendix C
7. CoC 1014, A17, Appendix D
8. CoC 1014, A17, Final Safety Evaluation Report

ML23328A004 (PKG), ML23328A005 (LTR), ML23328A027 (SER)

OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac WWheatley YDiaz-Sanabria DATE 11/27/2023 11/29/2023 12/1/2023 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NAME KBanovac YDiaz-Sanabria DATE 12/5/2023 12/5/2023