UNITED STATES COURT OF APPEALS FOR THE DISTRICT OF COLUMBIA CIRCUIT DON¶T WASTE MICHIGAN et al.,
)
Petitioners,
)
)
- v.
)
No. 21-1048, consolidated
)
with Nos. 21-1055, 21-1056, UNITED STATES NUCLEAR
)
21-1179, 21-1227, 21-1229, REGULATORY COMMISSION and
)
21-1230, 21-1231 the UNITED STATES OF AMERICA,
)
Respondents,
)
)
and
)
)
INTERIM STORAGE PARTNERS, L.L.C., )
Intervenor-Respondent. )
CERTIFIED INDEX OF THE RECORD I certify to the best of my knowledge and belief that the documents listed on the attached index constitute the record before the agency relating to (1) the issuance of Materials License No. SNM-2515 by the U.S. Nuclear Regulatory Commission on September 13, 2021, as set forth in Interim Storage Partners, LLC; WCS Consolidated Interim Storage Facility; Issuance of Materials License and Record of Decision, 86 Fed. Reg. 51,926 (Sept. 17, 2021); and (2) the adjudicatory proceedings culminating in issuance (a) by the Commission of CLI-20-13 (Dec. 4, 2020); CLI-20-14 (Dec. 17, 2020), CLI-20-15 (Dec. 17, 2020); and CLI-21-09 (June 22, 2021); and (b) by the Secretary of Orders dated October 25 and October 29, 2018.
USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 1 of 100
Respectfully Submitted, Annette L. Vietti-Cook Secretary of the Commission Dated at Rockville, Maryland this 18th day of November 2021 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 2 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 1
License application; docketing and opportunity to request a hearing and to petition for leave to intervene.
01/30/2017 82 FR 8773; January 30, 2017 2
License application; withdrawal of notice of opportunity to request a hearing.
07/20/2017 82 FR 33521; July 20, 2017 3
Revised license application; opportunity to request a hearing and to petition for leave to intervene; order imposing procedures.
08/29/2018 83 FR 44070; August 29, 2018 4
Correction (to hearing request due date) 08/31/2018 83 FR 44680; August 31, 2018 5
Sierra Club's Motion for Extension of Time to Intervene in Licensing Proceeding.
03/03/2017 ML17062A897 6
Request for Extension on Deadline.
03/09/2017 ML17069A492 RECORD OF ADJUDICATION CERTIFIED INDEX OF THE RECORD FOR INTERIM STORAGE PARTNERS - WCS CISF (NRC DOCKET 72-1050-ISFSI)
DON'T WASTE MICHIGAN, ET AL v US NRC US COURT OF APPEALS FOR THE DISTRICT OF COLUMBIA CIRCUIT CASE NO. 21-1048, consolidated with NOs. 21-1055, 21-1056, 21-1179, 21-1227, 21-1229, 21-1230 and 21-1231 Page 1 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 3 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 7
WCS Notices of Appearance for Stephen J. Burdick.
03/13/2017 ML17072A072 8
Notices of Appearance for Sara Kirkwood, David Cylkowski, and Emily Monteith.
03/13/2017 ML17072A489 9
Waste Control Specialists LLC's And Sierra Club's Joint Motion For Revised Schedule Related To Hearing Requests.
03/13/2017 ML17072A498 10 Waste Control Specialists LLC's Answer Opposing Nuclear Information And Resource Service's Letter Requesting An Extension Of Time And Proposing Approval Of Alternate Briefing Schedule.
03/17/2017 ML17076A365 11 NRC Staff's Response to the Nuclear Information and Resource Service's Motion for an Extension of Time to Request a Hearing 03/20/2017 ML17079A534 12 Sustainable Energy and Economic Development Coalition (SEED Coalition) Request for Extension of 120 Days for Submission of Hearing Requests and Petitions to Intervene (w/ attachments) 03/07/2017 ML17080A493 13 Waste Control Specialists LLC's Answer Opposing Sustainable Energy and Economic Development Coalition's Request for an Extension of Time and Proposing Approval of Alternate Briefing Schedule.
03/23/2017 ML17082A426 14 NRC Staff's Response to the Sustainable Energy and Economic Development Coalition's Letter Requesting an Extension of Time to Request a Hearing.
03/23/2017 ML17082A441 Page 2 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 4 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 15 Order of the Secretary re Extension of Time Until May 31, 2017 to File Hearing Requests on WCS's License Application.
03/29/2017 ML17088A627 16 March 22, 2017 Letter from Rafael Ancha, Texas State Representative, Regarding SEED Request for Extension of Time in the Matter of Waste Control Specialists 03/22/2017 ML17089A788 17 Joint Request To Withdraw The Federal Register Notice Providing An Opportunity To Submit Hearing Requests.
04/19/2017 ML17109A480 18 Response By Beyond Nuclear, Seed Coalition and Sierra Club to Joint Request to Withdraw the Federal Register Notice Providing an Opportunity to Submit Hearing Requests.
04/28/2017 ML17118A268 19 Notice of Appearance for Diane Curran on behalf of SEED Coalition and Beyond Nuclear.
04/28/2017 ML17118A269 20 Certificate of Service for Beyond Nuclear, SEED Coalition and Sierra Club's Response to Joint Request to Withdraw FRN.
04/28/2017 ML17118A270 21 Commission Memorandum and Order (CLI-17-10).
06/22/2017 ML17173A549 22 Beyond Nuclear, Inc.'s Motion to Dismiss Licensing Proceedings for HI-STORE Consolidated Interim Storage Facility and WCS Consolidated Interim Storage Facility for Violation of the Nuclear Waste Policy Act.
09/14/2018 ML18257A312 Page 3 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 5 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 23 Beyond Nuclear, Inc., Exhibits 1-8 to Motion to Dismiss Licensing Proceedings for Hi-Store Consolidated Interim Storage Facility and WCS Consolidated Interim Storage Facility for Violation of the Nuclear Waste Policy Act.
09/14/2018 ML18257A313 24 Notice of Appearance for Mindy Goldstein on behalf of Beyond Nuclear.
09/14/2018 ML18257A314 25 Notice of Appearance for Diane Curran on behalf of Beyond Nuclear.
09/14/2018 ML18257A315 26 Certificate of Service for Beyond Nuclear's Motion to Dismiss.
09/14/2018 ML18257A316 27 Errata to Beyond Nuclear's Motion to Dismiss Licensing Proceedings for HI-Store Consolidated Interim Storage Facility and WCS Consolidated Interim Storage Facility for Violation of the Nuclear Waste Policy Act.
09/18/2018 ML18261A110 28 Updated Notices of Appearance of Burdick, Matthews, and Lighty, and Notice of Appearance of Bessette on behalf of Interim Storage Partners.
09/24/2018 ML18267A298 29 Interim Storage Partners LLC's Response Opposing Beyond Nuclear, Inc.'s Unauthorized September 14, 2018 Filing.
09/24/2018 ML18267A299 30 NRC Staff's Response to Motions to Dismiss Licensing Proceedings.
09/24/2018 ML18267A313 31 Beyond Nuclear's Reply to Holtec International, Interim Storage Partners LLC, and NRC Staff Responses to Beyond Nuclear's Motion to Dismiss.
09/28/2018 ML18271A232 Page 4 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 6 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 32 Beyond Nuclear's Motion for Leave to Reply to Holtec International, Interim Storage Partners LLC, and NRC Staff Responses to Beyond Nuclear's Motion to Dismiss.
09/28/2018 ML18271A233 33 Notice of Appearance for Robert V. Eye on behalf of Fasken Land and Oil and Permian Basin Land and Royalty.
09/28/2018 ML18271A242 34 Motion of Fasken Land and Minerals, Ltd. and Permian Basin Land and Royalty Owners for Leave to Reply to NRC Staff's Response and Holtec International's Answer and Opposition to Motions to Dismiss.
09/28/2018 ML18271A243 35 Motion of Fasken Land and Minerals and Permian Basin Land and Royalty Owners to Dismiss Licensing Proceedings For Hi-Store Consolidated Interim Storage Facility and WCS Consolidated Interim Storage Facility.
09/28/2018 ML18271A244 36 Reply of Movants Fasken and PBLRO to Staff's Response to Motions to Dismiss.
09/28/2018 ML18271A245 37 Request for Extension on Deadline for Intervention by 37 Organizations and 4 Individuals.
10/02/2018 ML18276A066 38 Notices of Appearance by Diane Curran, Mindy Goldstein, and Caroline Reiser on behalf of Beyond Nuclear.
10/03/2018 ML18276A241 39 Beyond Nuclear, Inc.'s Hearing Request and Petition to Intervene.
10/03/2018 ML18276A242 Page 5 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 7 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 40 Interim Storage Partners LLC's Response Opposing Fasken Land and Minerals' and Permian Basin Land and Royalty Owners' Unauthorized September 28, 2018 Filing.
10/05/2018 ML18278A253 41 Interim Storage Partners LLC's Answer Opposing Motions for Leave to Reply Submitted by Beyond Nuclear, Fasken, and PBLRO.
10/05/2018 ML18278A264 42 Interim Storage Partners LLC's Answer Opposing Request for Extension of Intervention Deadline.
10/08/2018 ML18281A012 43 Motion of Movants Fasken Land and Minerals, Ltd. and Permian Basin Land and Royalty Owners for Leave to Reply to Interim Storage Partner LLC's Answer and Opposition to Movants Motions to Dismiss.
10/11/2018 ML18284A477 44 Amended Motion of Movants Fasken Land and Minerals, Ltd. and Permian Basin Land and Royalty Owners for Leave to Reply to Interim Storage Partner LLC's Answer and Opposition to Movants Motions to Dismiss.
10/11/2018 ML18284A496 45 Fasken Land and Minerals, Ltd. and Permian Basin Land and Royalty Owners' Amended Certificate of Consultation.
10/16/2018 ML18289A797 46 Interim Storage Partners LLC's Answer Opposing Motion For Leave To Reply Submitted By Fasken And PBLRO.
10/19/2018 ML18292A803 47 NRC Staff Commission Notification.
10/24/2018 ML18297A352 Page 6 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 8 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 48 Order of the Secretary.
10/25/2018 ML18298A335 49 Order of the Secretary.
10/29/2018 ML18302A329 50 NRC Staff's Response to Beyond Nuclear, Inc.'s Hearing Request and Petition to Intervene.
10/29/2018 ML18302A365 51 Petition of Permian Basin Land and Royalty Organization and Fasken Land and Minerals for Intervention and Request for Hearing.
10/29/2018 ML18302A412 52 Interim Storage Partners LLC's Answer Opposing Beyond Nuclear Inc.'s Hearing Request and Petition to Intervene.
10/29/2018 ML18302A413 53 Beyond Nuclear's Reply to Oppositions to Hearing Request and Petition to Intervene.
11/05/2018 ML18309A369 54 Joint Motion To Establish Briefing Schedule For Fasken's And PBLRO's Motion To Dismiss As Referred To The ASLBP For Consideration Under 10 C.F.R. 2.309.
11/07/2018 ML18311A267 55 Referral Memorandum from the Secretary to the Atomic Safety Licensing Board Panel 11/08/2018 ML18312A298 56 ORDER (Granting Joint Motion to Establish Briefing Schedule).
11/09/2018 ML18313A119 Page 7 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 9 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 57 Petition to Intervene and Request for Adjudicatory Hearing by Sierra Club.
11/13/2018 ML18317A411 58 Standing Declarations for Sierra Club in Support of Petition to Intervene and Request for Hearing.
11/13/2018 ML18317A412 59 Expert Declarations for Sierra Club in Support of Petition to Intervene and Request for Hearing.
11/13/2018 ML18317A413 60 Exhibits for Sierra Club in Support of Petition to Intervene and Request for Hearing.
11/13/2018 ML18317A414 61 Petition of Don't Waste Michigan, etc. to Intervene and Request for Hearing.
11/13/2018 ML18317A433 62 Declarations of Citizens for Alternatives to Chemical Contamination (CACC).
10/29/2018 ML18317A435 63 Declarations of Citizens Environmental Coalition (CEC).
11/13/2018 ML18317A436 64 Declaration of Leona Morgan.
10/29/2018 ML18317A437 65 Declarations of Don't Waste Michigan (DWM).
10/29/2018 ML18317A439 Page 8 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 10 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 66 Declarations of Public Citizen (PC).
10/29/2018 ML18317A440 67 Declarations of Sustainable Energy and Economic Development Coalition (SEED).
10/29/2018 ML18317A441 68 Expert Declaration Report of Robert Alvarez.
11/13/2018 ML18317A443 69 James Ballard Expert Report and CV.
11/13/2018 ML18317A444 70 Gordon Thompson Expert Report and CV.
11/13/2018 ML18317A445 71 Declarations of Nuclear Energy Information Service (NEIS).
11/13/2018 ML18317A446 72 Establishment of Atomic Safety Licensing Board.
11/16/2018 ML18320A095 73 Second Referral Memorandum from the Secretary to the Atomic Safety Licensing Board Panel.
11/16/2018 ML18320A221 74 Notice of Filing of Member Declarations of SLOMPF.
11/17/2018 ML18321A002 Page 9 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 11 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 75 Notice of Filing of Curriculum Vitae of Robert Alvarez.
11/17/2018 ML18321A003 76 Notice of Appearance of Wallace L. Taylor on behalf of Sierra Club.
11/20/2018 ML18324A553 77 Notice of Appearance for Alana Wase and Joe Gillespie on behalf of NRC Staff.
11/20/2018 ML18324A684 78 Notice of Appearance of Counsel for Don't Waste Michigan et al.
11/20/2018 ML18324A698 79 Interim Storage Partners LLC's Answer Opposing Fasken's and PBLRO's Motion to Dismiss as Referred to the ASLBP for Consideration Under 10 CFR 2.309.
11/20/2018 ML18324A886 80 Interim Storage Partners LLC's Answer Opposing Hearing Request and Petition to Intervene Filed by Permian Basin Land and Royalty Organization and Fasken Land and Minerals 11/20/2018 ML18324A892 81 NRC Staff's Response to Petitions to Intervene and Requests for Hearing Filed by Permian Basin Land and Royalty Organization and Fasken Land and Minerals.
11/23/2018 ML18327A071 82 Motion of Sierra Club, Don't Waste Michigan, et al for Disqualification of Atomic Safety and Licensing Board.
11/26/2018 ML18330A299 83 Fasken and PBLRO Reply to ISP's Opposition to Hearing Request and Petition to Intervene.
11/28/2018 ML18332A530 Page 10 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 12 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 84 Fasken and PBLRO Response to ISP's and Staff's Opposition to Fasken's and PBLRO's Motion to Dismiss as Referred to the ASLBP for Consideration Under 10 CFR 2.309.
11/30/2018 ML18334A360 85 Fasken's and PBLRO's Reply to Staff's Response to Hearing Request and Petition to Intervene.
11/30/2018 ML18334A361 86 NRC Staff Response to Motion for Disqualification of Atomic Safety and Licensing Board.
12/06/2018 ML18340A178 87 Interim Storage Partners LLC's Motion to Strike Portions of the Replies Filed by Permian Basin Land and Royalty Organization and Fasken Land and Minerals.
12/10/2018 ML18344A571 88 NRC Staff Consolidated Answer to Petitions to Intervene and Requests for Hearing.
12/10/2018 ML18344A594 89 Interim Storage Partners LLC's Answer Opposing Hearing Request and Petition to Intervene Filed by Sierra Club.
12/10/2018 ML18344A684 90 Interim Storage Partners LLC's Answer Opposing Hearing Request and Petition to Intervene Filed by DWM et al.
12/10/2018 ML18344A685 91 Memorandum and Order (Denying and Referring Motion to Disqualify Board) LBP-18-6.
12/13/2018 ML18347A393 92 Fasken and PBLRO's Opposition to Interim Storage Partners LLC's Motion to Strike.
12/17/2018 ML18351A335 Page 11 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 13 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 93 Sierra Club's Reply to Answers filed by Interim Storage Partners and NRC Staff.
12/17/2018 ML18351A531 94 Combined Reply of Don't Waste Michigan, Citizens' Environmental Coalition, Citizens for Alternatives to Chemical Contamination, Nuclear Energy Information Service, Public Citizen, Inc., etc. to ISP WCS and NRC Staff Answers.
12/17/2018 ML18351A640 95 Interim Storage Partners LLC's Motion to Strike Portions of the Reply Filed by Sierra Club.
12/27/2018 ML18361A921 96 to Interim Storage Partners LLC's Motion to Strike Portions of the Reply Filed by Sierra Club.
12/27/2018 ML18361A922 97 Interim Storage Partners LLC's Motion to Strike Portions of the Reply Filed by Don't Waste Michigan et al.
12/27/2018 ML18361A937 98 to Interim Storage Partners LLC's Motion to Strike Portions of the Reply Filed by Don't Waste Michigan et al.
12/27/2018 ML18361A939 99 Opposition of Joint Petitioners to ISP WCS Motion to Strike.
12/30/2018 ML18365A017 100 Sierra Club's Answer to Interim Storage Partners' Motion to Strike Portions of Sierra Club's Reply.
01/02/2019 ML19002A472 101 Order (Concerning Oral Argument).
01/10/2019 ML19010A376 Page 12 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 14 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 102 Notice of Beyond Nuclear's Petition for Review of NRC Order in D.C. Circuit U.S. Court of Appeals.
01/16/2019 ML19016A336 103 Notice of Withdrawal of Caroline Reiser.
02/06/2019 ML19037A322 104 Commission Memorandum and Order (CLI-19-03).
03/11/2019 ML19070A329 105 Notice of Withdrawal of Stephen J. Burdick.
04/02/2019 ML19092A382 106 Notice of Withdrawal of Emily Monteith.
04/24/2019 ML19114A453 107 Order (Regarding Location of Oral Argument).
05/07/2019 ML19127A031 108 Position Statements of Petitioners Don't Waste Michigan, et al., Beyond Nuclear, Sierra Club, Fasken Land and Oil and Permian Basin Land and Royalty Owners, and NRC Staff on Location of Oral Argument.
05/20/2019 ML19140A308 109 Interim Storage Partners LLC's Response Regarding Location of Oral Argument.
05/20/2019 ML19140A424 110 Notice and Order (Establishing Dates and Location of Oral Argument) 05/24/2019 ML19144A114 Page 13 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 15 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 111 Notice of Appearance for Thomas Steinfeldt on Behalf of NRC Staff.
06/03/2019 ML19154A477 112 E-mail from ASLB Law Clerk Joseph McManus to Midland County, TX Commissioner Randy Prude.
06/03/2019 ML19154A488 113 Interim Storage Partners Board Notification re ISP Letter E-54257.
06/03/2019 ML19154A586 114 to Interim Storage Partners Board Notification re ISP Letter E-54257.
06/03/2019 ML19154A587 115 to Interim Storage Partners Board Notification re ISP Letter E-54257.
06/03/2019 ML19154A588 116 to Interim Storage Partners Board Notification re ISP Letter E-54257.
06/03/2019 ML19154A589 117 Order (Establishing Format for Oral Argument).
06/07/2019 ML19158A402 118 Notice of Appearance for Timothy Laughlin on Behalf of Fasken and PBLRO 06/12/2019 ML19163A391 119 Interim Storage Partners Board Notification re ISP Letter E-54423.
06/28/2019 ML19179A307 Page 14 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 16 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 120 to Interim Storage Partners Board Notification re ISP Letter E-54423.
06/28/2019 ML19179A308 121 to Interim Storage Partners Board Notification re ISP Letter E-54423.
06/28/2019 ML19179A309 122 to Interim Storage Partners Board Notification re ISP Letter E-54423.
06/28/2019 ML19179A310 123 Interim Storage Partners LLC's Response to the Atomic Safety And Licensing Board's Questions Regarding the U.S. Department of Energy's Authority Under the Nuclear Waste Policy Act.
06/28/2019 ML19179A311 124 Hearing Transcript of July 10, 2019 Oral Arguments in the Matter of Interim Storage Partners, LLC. Pages 1-207.
07/10/2019 ML19198A218 125 Hearing Transcript of July 10, 2019 Oral Arguments in the Matter of Interim Storage Partners, LLC. Pages 208-342.
07/11/2019 ML19198A219 126 Memorandum and Order (Ruling on Petitions for Intervention and Requests for Hearing) (LBP-19-07) 08/23/2019 ML19235A165 127 Letter from NRC Acting Secretary to Richard Guldi of Dallas Sierra Club 08/26/2019 ML19238A313 128 NRC Staff Notice of Intent to Participate as a Party 08/30/2019 ML19242D526 Page 15 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 17 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 129 Joint Motion Regarding an Agreement for Mandatory Disclosures and Hearing File Obligations.
08/30/2019 ML19242D648 130 ORDER (Granting Joint Motion Regarding Mandatory Disclosures and Hearing File Obligations) 09/04/2019 ML19247C334 131 Order (Scheduling Initial Scheduling Conference) 09/05/2019 ML19248C450 132 Licensing Board Notification Regarding ISP Letter E-55041.
09/05/2019 ML19248C912 133 ISP Transmittal Letter E-55041 Providing Supplemental Information re References from the Environmental Report Chapter 3.
09/04/2019 ML19248C915 134 to ISP Letter E-55041 re Ecological Assessment of the Low Level Depository, Final Report.
05/31/1997 ML19248C918 135 to ISP Letter E-55041 re Final Report on Habitat Characterization and Rare Species Survey for the Proposed Low Level Waste Repository.
10/25/2004 ML19248C922 136 to ISP Letter E-55041 re Final Report (Rev. 1) on Supplemental Survey Ecological Assessment of the Low Level Waste Depository.
03/31/2007 ML19248C925 137 to ISP Letter E-55041 re Environmental Assessment Report.
07/31/2008 ML19248C927 Page 16 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 18 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 138 NRC Staff's Safety and Environmental Review Schedule 09/09/2019 ML19252A253 139 Interim Storage Partners LLC's Motion to Dismiss Sierra Club's Contention 13 as Moot and Terminate This Proceeding 09/09/2019 ML19252A322 140 Notice of Withdrawal of Robert V. Eye 09/12/2019 ML19255F793 141 Sierra Club's Resistance to ISP's Motion to Dismiss Sierra Club's Contention 13 09/12/2019 ML19255G961 142 Sierra Club's Motion to Amend Contention 13 09/13/2019 ML19256C635 143 Sierra Club's Amended Contention 13 09/13/2019 ML19256C638 144 Notice of Appearance for Kevin C. Roach on behalf of NRC Staff.
09/17/2019 ML19260G160 145 Beyond Nuclear's Notice of Appeal of LBP-19-07.
09/17/2019 ML19260G875 146 Beyond Nuclear's Brief on Appeal of LBP-19-07.
09/17/2019 ML19260G878 Page 17 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 19 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 147 Beyond Nuclear Certificate of Service for Appeal of LBP-19-07.
09/17/2019 ML19260G879 148 Interim Storage Partners LLC's Notice of Appeal of LBP-19-7 and Brief in Support of Appeal.
09/17/2019 ML19260H452 149 Fasken and PBLRO's Brief on Appeal of LBP-19-07 09/17/2019 ML19260J386 150 Fasken and PBLRO's Notice of Appeal of LBP-19-07 09/17/2019 ML19260J387 151 Fasken and PBLRO's Certificate of Service of Notice of Appeal and Brief on Appeal of LBP-19-07 09/17/2019 ML19260J388 152 Don't Waste Michigan, et al., Notice of Appeal of LBP 07 and Brief in Support of Appeal.
09/17/2019 ML19260J391 153 Transcript of September 18, 2019 Teleconference on WCS / Interim Storage Partners.
09/20/2019 ML19263B970 154 Interim Storage Partners' Licensing Board Notification Regarding Supplemental Information Being Provided to U.S. Nuclear Regulatory Commission Staff 09/20/2019 ML19263F035 155 ISP Answer Opposing Sierra Club's Motion to Amend Contention 13.
10/01/2019 ML19274E207 Page 18 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 20 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 156 to ISP Answer to Sierra Club Amended Contention 13.
10/01/2019 ML19274E211 157 to ISP Answer to Sierra Club Amended Contention 13.
10/01/2019 ML19274E215 158 to ISP Answer to Sierra Club Amended Contention 13.
10/01/2019 ML19274E218 159 Sierra Club's Reply to ISP's Answer to Sierra Club's Motion to Amend Contention 13 10/07/2019 ML19280A027 160 NRC Staff Answer Opposing Sierra Club's Amended Contention 13.
10/07/2019 ML19280D549 161 Order (Circulating Draft Initial Scheduling Order) 10/08/2019 ML19281B546 162 Sierra Club's Brief in Opposition to ISP's Appeal of ASLB Decision Admitting Sierra Club's Contention 13.
10/13/2019 ML19286A001 163 Sierra Club's Reply to NRC Staff's Answer to Sierra Club's Motion to Amend Contention 13.
10/14/2019 ML19287A021 164 NRC Staff's Answer In Opposition To The Appeal Of Fasken Land And Minerals, Ltd. And The Permian Basin Land And Royalty Owners Of LBP-19-7.
10/15/2019 ML19288A224 Page 19 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 21 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 165 NRC Staff's Answer In Opposition To Don't Waste Michigan, Et Al.'s Appeal of LBP-19-7.
10/15/2019 ML19288A228 166 NRC Staff's Answer In Opposition To Interim Storage Partners LLC's Appeal Of LBP-19-7.
10/15/2019 ML19288A232 167 Interim Storage Partners LLC's Answer Opposing the Appeal of LBP-19-7 by Don't Waste Michigan et al.
10/15/2019 ML19288A282 168 Interim Storage Partners LLC's Answer Opposing Fasken's and PBLRO's Appeal of LBP-19-7 10/15/2019 ML19288A283 169 Interim Storage Partners LLC's Answer Opposing Beyond Nuclear's Appeal of LBP-19-7.
10/15/2019 ML19288A287 170 Initial Scheduling Order 10/16/2019 ML19289B740 171 Corrected Certificate of Service for ISP Answer to Fasken Appeal of LBP-19-7 10/16/2019 ML19289E001 172 Motion of Intervenor Sustainable Energy and Economic Development Coalition for Leave to File Late-Filed Contention and Contention 17.
10/23/2019 ML19297A226 173 Declaration of Robert Alvarez in Support of Motion of Intervenor Sustainable Energy and Economic Development Coalition for Leave to File Late-Filed Contention.
10/23/2019 ML19297A229 Page 20 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 22 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 174 Robert Alvarez Curriculum Vitae Filed in Support of Motion of Intervenor Sustainable Energy and Economic Development Coalition for Leave to File Late-Filed Contention.
10/23/2019 ML19297A232 175 Nuclear Waste Technical Review Board Report Filed in Support of Motion of Intervenor Sustainable Energy and Economic Development Coalition for Leave to File Late-Filed Contention.
09/30/2019 ML19297A235 176 Notice of Appearance for Monica R. Perales on behalf of Fasken Oil and Ranch & Permian Basin Land and Royalty Owners.
10/24/2019 ML19297H647 177 Referral Memorandum from the Secretary to the Atomic Safety and Licensing Board Panel 11/13/2019 ML19317E079 178 Memorandum and Order (Ruling on Motion to Dismiss and Motion to Amend Contention 13) (LBP-19-9) 11/18/2019 ML19322C599 179 NRC Staff Answer in Opposition to Sustainable Energy and Economic Development Coalition's New Contention 17.
11/18/2019 ML19322C992 180 Interim Storage Partners LLC's Answer Opposing Petitioner Sustainable Energy and Economic Development Coalition's Motion for Leave to Submit Late-Filed Contention 17 11/18/2019 ML19322D453 181 Reply of Sustainable Energy and Economic Development Coalition in Support of Motion for Leave to File Late-Filed Contention 17.
11/25/2019 ML19329F937 182 Notice of Appearance for Allan Kanner, Conlee Whiteley, Elizabeth Petersen and Cynthia St. Amant on behalf of Fasken and PBLRO.
12/09/2019 ML19343A995 Page 21 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 23 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 183 Letter from NRC Secretary, Annette Vietti-Cook, to Tommy Taylor of Fasken Oil and Ranch 12/11/2019 ML19345E984 184 Letter from NRC Secretary, Annette Vietti-Cook, to A.
James Mayer of Green Century Exploration and Production 12/11/2019 ML19345E987 185 Memorandum and Order (Ruling on Motion for Leave to File Late-Filed Contention and Terminating Proceeding)
(LBP-19-11) 12/13/2019 ML19347A381 186 Sierra Club's Notice of Appeal from Atomic Safety and Licensing Board Rulings Denying Intervention (LBP-19-07 and LBP-19-09) 12/13/2019 ML19347E392 187 Sierra Club's Brief in Support of Appeal from Atomic Safety and Licensing Board Rulings Denying Admissibility of Contentions in Licensing Proceeding (LBP-19-07 and LBP-19-09).
12/13/2019 ML19347E441 188 Notice of Appearance for Nicholas Moran on behalf of NRC Staff.
01/06/2020 ML20006F306 189 NRC Staff's Answer in Opposition to Sierra Club's Appeal of LBP-19-7 and LBP-19-9.
01/07/2020 ML20007F038 190 Interim Storage Partners LLC's Answer Opposing Sierra Club's Appeal of LBP-19-7 and LBP-19-9 01/07/2020 ML20007G369 191 Notice of Appeal of LBP-19-11 by Intervenor Sustainable Energy and Economic Development Coalition and Brief in Support of Appeal.
01/07/2020 ML20007K164 Page 22 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 24 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 192 Fasken and PBLRO Access to SUNSI Information Request 01/16/2020 ML20016A453 193 Fasken Oil and Ranch, Ltd And Permian Basin Land and Royalty Owners Motion to Reopen the Record for Purposes of Considering and Admitting an Amended Contention.
01/21/2020 ML20021A384 194 Fasken Oil and Ranch, Ltd and Permian Basin Land and Royalty Owners Motion for Leave to Amend Contention Four.
01/21/2020 ML20021A385 195 Affidavit of Aaron Pachlhofer Filed in Support of Fasken and PBLRO's Motion to Reopen the Record for Purposes of Considering and Admitting an Amended Contention 01/21/2020 ML20021A386 196 Interim Storage Partners LLC's Answer Opposing Petitioner Sustainable Energy and Economic Development Coalition's Appeal of Licensing Board Decision LBP-19-11 02/03/2020 ML20034D891 197 NRC Staff'S Answer Opposing Sustainable Energy and Economic Development Coalition's Appeal of LBP-19-11.
02/03/2020 ML20034F184 198 NRC Staff's Response to Sustainable Energy and Economic Development Coalition's Appeal of LBP-19-11 (with Amended Certificate of Service).
02/03/2020 ML20034G078 199 Appeal of Staff Denial of Petitioners Request for SUNSI Information Related to ISPs Responses to RAIs.
02/12/2020 ML20043F076 200 Interim Storage Partners LLC's Answer Opposing Fasken's and PBLRO's Motion to Reopen the Record and Motion for Leave to Amend Contention Four.
02/18/2020 ML20049A373 Page 23 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 25 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 201 NRC Staff's Answer in Opposition to Fasken Amended Contention 4 and Accompanying Motion to Reopen the Record.
02/18/2020 ML20049A577 202 NRC Staff Answer to Fasken's Letter Appeal of Staff Denial of Petitioners' Request for SUNSI Information.
02/18/2020 ML20049A604 203 Interim Storage Partners LLC's Answer Opposing Fasken's and PBLRO's Motion to Reverse NRC Staff's SUNSI Access Denial.
02/18/2020 ML20049H533 204 Fasken Oil and Ranch, LTD.'s and Permian Basin Land and Royalty Owners' Reply to Interim Storage Partners, LLC's Answer Opposing Motion for Leave to Reopen the Record and Associated Motion for Leave to Amend Contention Four.
02/25/2020 ML20056E908 205 Notice of Withdrawal of Timothy J. Laughlin on behalf of Fasken and PBLRO.
04/06/2020 ML20097E037 206 Fasken Land and Minerals, Ltd.'s and Permian Basin Land and Royalty Owners' Unopposed Motion to Extend Deadlines Pending the COVID-19 National Emergency 05/18/2020 ML20139A226 207 Order (Extending Time to Intervene, Request a Hearing, and File New Contentions) Based on the Draft Environmental Impact Statement.
05/22/2020 ML20143A239 208 Fasken Land and Minerals, Ltd.'s and Permian Basin Land and Royalty Owners Motion to Reopen the Record.
07/06/2020 ML20188A390 209 Fasken Land and Minerals, Ltd.'s and Permian Basin Land and Royalty Owners' Motion for Leave to File New and/or Amended Contention.
07/07/2020 ML20189A000 Page 24 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 26 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 210 Exhibit 1 to Fasken and PBLRO's Motion for Leave to File New and/or Amended Contention - Declaration of Tommy E. Taylor.
07/07/2020 ML20189A001 211 Exhibit 2 to Fasken and PBLRO's Motion for Leave to File New and/or Amended Contention - Facts Petitioners Intend to Rely on to Support New and Amended Contentions.
07/07/2020 ML20189A002 212 Notice of Appearance for Rebecca Susko on behalf of NRC Staff.
07/28/2020 ML20210M366 213 NRC Staff's Answer in Opposition to Fasken Oil and Ranch, Ltd.'s and Permian Basin Land and Royalty Owners' Motions to Reopen the Record and File New Contention 5.
07/31/2020 ML20213C523 214 Interim Storage Partners LLC's Answer Opposing Fasken's And PBLRO's Second Motion To Reopen The Record And Motion For Leave To File New Contention 5.
07/31/2020 ML20213C708 215 Fasken Land and Minerals, Ltd.'s and Permian Basin Land and Royalty Owners' Combined Reply to NRC Staff's and Interim Storage Partners LLC's Oppositions to Motion for Leave to File New Contention and Motion to Reopen The Record 08/07/2020 ML20220A746 216 Letter from NRC Acting Secretary Richard J. Laufer to Dr.
Elliot J. Trester of Texas Physicians for Social Responsibility 10/09/2020 ML20283A713 217 Letter from NRC Secretary Annette Vietti-Cook to Kevin Kamps of Beyond Nuclear, et al.
11/12/2020 ML20317A297 218 Commission Memorandum and Order (CLI-20-13).
12/04/2020 ML20339A519 Page 25 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 27 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 219 Notice of Withdrawal for Rebecca Susko on behalf of NRC Staff 12/09/2020 ML20344A425 220 Notice of Appearance for Annemieke M. Tennis on behalf of Fasken & PBLRO.
12/15/2020 ML20350B758 221 Commission Memorandum and Order (CLI-20-14) 12/17/2020 ML20352A359 222 Commission Memorandum and Order (CLI-20-15) 12/17/2020 ML20352A360 223 Notice of Withdrawal of Joe Gillespie on behalf of NRC Staff 01/04/2021 ML21004A156 224 Memorandum and Order (Denying Motions to Reopen and for Leave to File) (LBP-21-02) 01/29/2021 ML21029A084 225 Fasken Land and Minerals, Ltd.'s and Permian Basin Land and Royalty Owners' Combined Notice of Appeal and Petition for Review of Atomic Safety Licensing Board's Denial of Motion for Leave to File New Contention No. 5 and Motion to Reopen the Record.
02/23/2021 ML21054A331 226 Notice of Appearance for Reginald Augustus on behalf of NRC Staff.
03/09/2021 ML21068A171 227 Interim Storage Partners, LLC's Answer Opposing Fasken Petition for Review of LBP-21-2 03/22/2021 ML21081A208 Page 26 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 28 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 228 NRC Staff's Answer in Opposition to Fasken's Petition for Review of LBP-21-2 03/22/2021 ML21081A221 229 Letter from NRC Secretary to Glenn LeMunyon for Fasken Oil and Ranch 04/01/2021 ML21091A088 230 Commission Memorandum and Order (CLI-21-09) 06/22/2021 ML21173A148 231 Initial application, safety analysis report (SAR) and environmental report (ER), dated April 28, 2016 04/28/2016 ML16133A070 (Package) 232 Waste Control Specialists, LLC, Consolidated Interim Spent Fuel Storage Facility License Application 04/28/2016 ML16182A162 (Package) 233 Letter to S Kirk, Waste Control Specialists, LLC, Acceptance Review of Specific License Application Requesting Authorization to Construct and Operate a Consolidated Interim Storage Facility for Spent Nuclear Fuel-Supplemental Information Needed 06/22/2016 ML16175A277 (Package) 234 RSI Response Schedule 07/06/2016 ML16193A314 235 RSI Response 1 07/20/2016 ML16229A549 RECORD OF LICENSING ACTION Page 27 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 29 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 236 RSI Response 2 08/31/2016 ML16265A454 237 RSI Response 3 10/07/2016 ML16294A134 (Package) 238 RSI Response 4 11/16/2016 ML16330A116 (Package) 239 RSI Response 5 12/16/2016 ML16356A346 (Package) 240 RSI Response 6 12/22/2016 ML17018A292 (Package) 241 Acceptance Letter, January 26, 2017 01/26/2017 ML17018A168 242 Transcript of Environmental Impact Statement - Scoping Process 02/13/2017 Meeting 02/13/2017 ML17061A744 243 Transcript of Environmental Impact Statement - Scoping Process 02/15/2017 Meeting 02/15/2017 ML17062A614 244 Notice of March 1, 2017 Public Meeting on Safety Review 02/15/2017 ML17047A326 Page 28 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 30 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 245 Environmental Impact Statement - Scoping Process 02/13/2017, 02/15/2017 and 02/23/2017 Meeting Presentation and Background Material 02/23/2017 ML17058A036 (Package) 246 Environmental Impact Statement - Scoping Process 02/13/2017, 02/15/2017 and 02/23/2017 Meeting Presentation and Background Material - Spanish Version 02/23/2017 ML17069A300 247 Transcript of Environmental Impact Statement - Scoping Process 02/23/2017 Meeting 02/23/2017 ML17067A323 248 WCS Presentation Slides for March 1, 2017 Public Meeting on Safety Review 02/24/2017 ML17055C176 249 Summaries of 02/13/2017, 02/15/2017 and 02/23/2017 Public Scoping Meetings on Environmental Impact Statement for WCS Proposed Consolidated Interim Storage Facility 03/13/2017 ML17072A442 250 April 6, 2017 Public Scoping Meeting Notice 03/13/2017 ML17072A248 251 Application Revision 1, SAR Revision 1, and ER Revision 1, dated March 16, 2017 03/16/2017 ML17082A021 (Package) 252 Transcript of Environmental Impact Statement -
04/06/2017 Public Scoping Meeting 04/06/2017 ML17102B446 253 Summary of March 1, 2017 Public Meeting on Safety Review 04/06/2017 ML17100A250 Page 29 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 31 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 254 April 6, 2017 Scoping Meeting Presentation and Background Material 04/26/2017 ML17110A107 255 April 6, 2017 Scoping Meeting Presentation and Background Material (Spanish Language Version) 04/26/2017 ML17110A109 256 April 6, 2017 Public Scoping Meeting Summary 05/03/2017 ML17116A510 257 Application Revision 2, SAR Revision 2, and ER Revision 2, dated July 19, 2018 07/19/2018 ML18206A595 (Package) 258 Applicant response to request for additional information, dated July 19, 2018 07/19/2018 ML18208A437 259 Notice of August 29, 2018 Public Meeting on Safety Review 08/09/2018 ML18221A267 260 Acceptance Letter, August 21, 2018 08/21/2018 ML18225A281 261 ISP Presentation Slides for August 29, 2018 Public Meeting on Safety Review 08/29/2018 ML18241A329 262 Summary of August 29, 2018 Public Meeting on Safety Review 09/25/2018 ML18267A214 (Package) 263 Part 1 - Physical Security (Cover letter only, enclosure withheld) (November 6, 2018) 11/06/2018 ML18310A069 Page 30 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 32 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 264 First RAI, Part 1 (November 16, 2018) 11/16/2018 ML18320A184 265 Notice of January 10, 2019 Public Meeting on Safety Review 12/21/2018 ML18355A981 266 Applicant response to request for additional information, dated January 7, 2019 01/07/2019 ML19009A099 267 ISP Presentation Slides for January 10, 2019 Public Meeting on Safety Review 01/08/2019 ML19008A296 268 Summary of January 10, 2019 Public Meeting on Safety Review 02/04/2019 ML19032A230 269 Notice of February 19, 2019 Public Meeting on Safety Review 02/07/2019 ML19038A440 270 Background Information for March 20, 2019 Public Meeting on Safety Review - Draft Consolidated Emergency Plan 02/08/2019 ML19073A252 271 ISP Presentation Slides for February 19, 2019 Public Meeting on Safety Review 02/19/2019 ML19050A019 272 First RAI, Part 2 (March 6, 2019) 03/06/2019 ML19065A019 273 Notice of March 20, 2019 Public Meeting on Safety Review 03/07/2019 ML19066A273 Page 31 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 33 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 274 Background Information for March 20, 2019 Public Meeting on Safety Review - Submission of ISP Draft Responses for RAls NP-2.2-1, NP-2.2-2 and EP-X 03/12/2019 ML19073A251 275 Background Information for March 20, 2019 Public Meeting on Safety Review - WCS Draft Responses 03/12/2019 ML19073A253 276 Summary of February 19, 2019 Public Meeting on Safety Review 03/14/2019 ML19072A156 277 Applicant response to request for additional information, dated March 22, 2019 03/22/2019 ML19122A034 278 Notice of April 11, 2019 Public Meeting on Safety Review 03/28/2019 ML19092A195 279 Background Information for April 11, 2019 Public Meeting on Safety Review - Submission of ISP Draft Responses for RAls NP-2.4-x, NP-2.6-x, P-2.6-x 04/01/2019 ML19093A183 (Package) 280 Background Information for April 16, 2019 Public Meeting on Safety Review - Submission of ISP Draft Responses for RAls NP-15-x and P-15-x 04/03/2019 ML19095B557 (Package) 281 Notice of April 16, 2019 Public Meeting on Safety Review 04/04/2019 ML19094B861 282 Summary of March 20, 2019 Public Meeting on Safety Review 04/19/2019 ML19105B217 Page 32 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 34 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 283 First RAI, Part 3 (April 23, 2019) 04/23/2019 ML19120A428 284 Summary of April 11, 2019 Public Meeting on Safety Review 05/03/2019 ML19123A023 285 Summary of April 16, 2019 Public Meeting on Safety Review 05/06/2019 ML19126A066 286 Applicant response to request for additional information, dated May 31, 2019 05/31/2019 ML19156A048 (Package) 287 ISP First Round RAI Proposed Submittal Schedule 05/31/2019 ML19156A059 288 Applicant response to request for additional information, dated June 26, 2019 06/26/2019 ML19197A044 289 Applicant response to request for additional information, dated June 28, 2019 06/28/2019 ML19184A159 (Package) 290 Applicant response to request for additional information, dated June 28, 2019 06/28/2019 ML19190A227 (Package) 291 Revised Review Schedule Letter, July 1, 2019 07/01/2019 ML19182A107 Page 33 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 35 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 292 Background Information for September 12, 2019 Public Meeting on Safety Review - Submission of ISP Draft Responses for Several RAls and Associated Document Markups from First Request For Additional Information, Part 2, Docket 72-1050 CAC/EPID 001028/L-2017-NEW-0002 07/26/2019 ML19211D084 293 Applicant response to request for additional information, dated July 31, 2019 07/31/2019 ML19217A231 (Package) 294 Applicant response to request for additional information, dated August 20, 2019 08/20/2019 ML19235A157 (Package) 295 Notice of September 12, 2019 Public Meeting on Safety Review 08/27/2019 ML19239A201 296 Submission of Draft Responses for Several RAls and Associated Document Markups from First Request For Additional Information, Part 2, dated August 30, 2019 08/30/2019 ML19252A132 (Package) 297 Applicant response to request for additional information, dated September 18, 2019 09/18/2019 ML19270E399 298 Applicant submittal of supplemental information, dated September 20, 2019 09/20/2019 ML19268A113 (Package) 299 Submission of ISP Draft Responses for Several RAls and Associated Document Markups from First Request For Additional Information, Part 3, dated October 8, 2019 -
Transmittal Letter 10/08/2019 ML19283B556 Page 34 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 36 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 300 Submission of ISP Draft Responses for Several RAls and Associated Document Markups from First Request For Additional Information, Part 3, dated October 8, 2019 -
10/08/2019 ML19283B557 301 Summary of September 12, 2019 Public Meeting on Safety Review 10/10/2019 ML19281D885 302 Notice of October 24, 2019 Public Meeting on Environmental Requests for Additional Information 10/11/2019 ML19284B621 303 Summary Report of Environmental Impact Statement 04/06/2017 Public Scoping Meeting 10/31/2019 ML19161A150 304 Part 4 (November 5, 2019) - Environmental Impact Statement 11/05/2019 ML19309E913 305 Applicant response to request for additional information, dated November 21, 2019 11/21/2019 ML19337B502 (Package) 306 Summary of October 24, 2019 Public Meeting on Environmental Requests for Additional Information 11/22/2019 ML19326B216 307 Applicant response to request for additional information, dated January 6, 2020 01/06/2020 ML20015A448 (Package) 308 Applicant response to request for additional information, dated January 17, 2020 01/17/2020 ML20028E843 (Package)
Page 35 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 37 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 309 Applicant response to request for additional information, dated January 22, 2020 01/22/2020 ML20028D890 (Package) 310 Part 1 - Materials Clarification Questions (February 3, 2020) 02/03/2020 ML20034E835 311 Applicant response to request for additional information, dated February 14, 2020 02/14/2020 ML20052D995 (Package) 312 Applicant response to request for additional information, dated February 14, 2020 02/14/2020 ML20052E047 (Package) 313 ISP Updated First Round RAI Proposed Submittal Schedule 02/14/2020 ML20050D259 314 ER Revision 3, dated February 17, 2020 02/17/2020 ML20052E144 (Package) 315 Applicant submittal of supplemental information, dated March 5, 2020 03/05/2020 ML20071F152 (Package) 316 March 11, 2020 Clarification Responses 03/11/2020 ML20076D714 (Package) 317 Applicant response to request for additional information, dated March 16, 2020 03/16/2020 ML20083J964 (Package)
Page 36 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 38 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 318 Applicant response to request for additional information, dated April 7, 2020 04/07/2020 ML20105A133 (Package) 319 Applicant response to request for additional information, dated April 7, 2020 04/07/2020 ML20105A171 (Package) 320 Federal Register Notice (Includes directions on How to Comment on Draft EIS) 05/08/2020 85 FR 27449; May 8, 2020 321 Applicant response to request for additional information, dated May 18, 2020 05/18/2020 ML20139A173 (Package) 322 SAR Revision 3, dated May 22, 2020 05/22/2020 ML20150A337 (Package) 323 Draft Environmental Impact Statement, dated May 2020 05/31/2020 ML20122A220 324 Overview of the Draft Environmental Impact Statement, dated May 2020 05/31/2020 ML20121A016 325 Overview of the Draft Environmental Impact Statement (Spanish language version), dated May 2020 05/31/2020 ML20136A148 326 Applicant response to request for additional information, dated June 11, 2020 06/11/2020 ML20163A008 Page 37 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 39 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 327 Applicant submittal of supplemental information, dated July 21, 2020 07/21/2020 ML20203M040 328 Application Revision 3, dated August 24, 2020 08/24/2020 ML20237F470 329 SAR Revision 4, September 2, 2020 09/02/2020 ML20261H419 (Package) 330 October 1, 2020 Webinar Public Meeting Presentation Slides 09/16/2020 ML20274A035 331 Draft Environmental Impact Statement Public Meetings -
October 1, 2020 Webinar 09/17/2020 ML20261H356 332 Draft Environmental Impact Statement Public Meetings -
October 8, 2020 Webinar 09/17/2020 ML20261H374 333 Draft Environmental Impact Statement Public Meetings -
October 15, 2020 Webinar 09/17/2020 ML20261H380 334 October 1, 2020 Webinar Public Meeting Presentation Slides (Spanish Language Version) 09/30/2020 ML20274A036 335 Draft Environmental Impact Statement Public Meetings -
October 1, 2020 Webinar 10/01/2020 ML20260H210 Page 38 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 40 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 336 Transcript of Draft Environmental Impact Statement Public Meeting October 1, 2020 Webinar 10/01/2020 ML20288A206 337 October 6, 2020 Webinar Public Meeting Presentation Slides 10/02/2020 ML20279A355 338 October 6, 2020 Webinar Public Meeting Presentation Slides (Spanish Language Version) 10/02/2020 ML20279A356 339 Transcript of Draft Environmental Impact Statement Public Meeting October 6, 2020 Webinar 10/06/2020 ML20288A242 340 October 8, 2020 Webinar Public Meeting Presentation Slides 10/08/2020 ML20279A516 341 October 8, 2020 Webinar Public Meeting Presentation Slides (Spanish Language Version) 10/08/2020 ML20279A517 342 Transcript of Draft Environmental Impact Statement Public Meeting October 8, 2020 Webinar 10/08/2020 ML20294A435 343 Revised Review Schedule Letter, October 9, 2020 10/09/2020 ML20282A351 344 October 15, 2020 Webinar Public Meeting Presentation Slides 10/15/2020 ML20279A763 Page 39 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 41 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 345 October 15, 2020 Webinar Public Meeting Presentation Slides (Spanish Language Version) 10/15/2020 ML20279A764 346 Transcript of Draft Environmental Impact Statement Public Meeting October 15, 2020 Webinar 10/15/2020 ML20297A255 347 Errata for Transcript of Draft Environmental Impact Statement Public Meeting October 8, 2020 Webinar 11/06/2020 ML20315A023 348 January 14, 2021 Supplemental Information to Part 2 RAI Responses 01/14/2021 ML21014A063 349 Applicant submittal of supplemental information, dated January 27, 2021 01/27/2021 ML21027A147 350 Application Revision 4 and SAR Revision 5, dated April 12, 2021 04/12/2021 ML21105A766 (Package) 351 Final Environmental Impact Statement, dated July 2021 07/31/2021 ML21209A955 352 Overview of the Final Environmental Impact Statement, dated July 2021 07/31/2021 ML21200A050 353 Letter from Texas Governor Greg Abbott 09/10/2021 ML21256A264 Page 40 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 42 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 354 NRC Staff¶s Record of Decision, dated September 13, 2021 09/13/2021 ML21222A214 355 Materials License for ISP, dated September 13, 2021 09/13/2021 ML21188A096 (Package) 356 Letter from Allan Kanner on behalf of Permian Basin Coalition of Land and Royalty Owners and Operators and Fasken Land and Minerals, Ltd.
09/11/2021 ML21258A404 357 Letter from William Grantham, New Mexico Assistant Attorney General 09/13/2021 ML21274A155 358 Letter from James Kenney, Secretary of the New Mexico Environment Department 09/14/2021 ML21278A544 359 Email to Annemieke Tennis, Monica Perales and Allan Kanner 09/23/2021 ML21278A394 360 Final Safety Evaluation Report, dated September 2021 09/30/2021 ML21188A101 361 Letter to James Kenney, Secretary of the New Mexico Environment Department 10/14/2021 ML21280A339 362 Letter to William Grantham, New Mexico Assistant Attorney General 10/14/2021 ML21281A093 363 Letter to Texas Governor Greg Abbott 10/21/2021 ML21265A263 Page 41 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 43 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER Commenter Affiliation (if stated)
Comment Source and Document ID 364 Abbott, Greg State of Texas www.regulations.
gov (ML20309A385) 365 Acosta, Jazmin www.regulations.
gov (ML20295A198) 366 Albright, Bud United States Nuclear Industry Council Email (ML20311A204) 367 Allen, Catherine Email (ML20282A629) 368 Anderson, Dorothy www.regulations.
gov (ML20296A547) 369 Anonymous, Anonymous www.regulations.
gov (ML20211M112) 370 Anonymous, Anonymous www.regulations.
gov (ML20233A241)
PUBLIC COMMENTS ON DRAFT ENVIRONMENTAL IMPACT STATEMENT (UNIQUE)
Page 42 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 44 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 371 Anonymous, Anonymous www.regulations.
gov (ML20268B232) 372 Anonymous, Anonymous www.regulations.
gov (ML20290A362) 373 Anonymous, Anonymous www.regulations.
gov (ML20294A404) 374 Anonymous, Anonymous www.regulations.
gov (ML20302A008) 375 Anonymous, Anonymous www.regulations.
gov (ML20308A426) 376 Anonymous, Anonymous City of Arlington, TX www.regulations.
gov (ML20266G517) 377 Arends, Joni Concerned Citizens for Nuclear Safety Email (ML20309B074) 378 Arends, Joni Concerned Citizens for Nuclear Safety Meeting Transcript (ML20288A206)
Page 43 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 45 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 379 Arnold, Richard Tribal Radio-active Materials Transpor-tation Committee www.regulations.
gov (ML20309A406) 380 Aros, George Email (ML20307A301) 381 Atteberry, Barbara Email (ML20281A819) 382 Austin, Landry Idaho Department of Environmental Quality www.regulations.
gov (ML20309A400) 383 Baker, Robert Meeting Transcript (ML20294A435) 384 Baker, Toby Texas Commission on Environmental Quality www.regulations.
gov (ML20309A396) 385 Barnard, Edward Email (ML20305A501) 386 Barnes, Margaret Texas RioGrande Legal Aid Email (ML20309B0) 387 Bartelt, Jeannette Email (ML20172A154)
Page 44 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 46 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 388 Beaudoin, Mary www.regulations.
gov (ML20245E429) 389 Beaulah, Pat Meeting Transcript (ML20288A206) 390 Beaulah, Pat Meeting Transcript (ML20297A255) 391 Belisle, Mavis Nuclear Free World Committee of the Dallas Peace and Justice Center Email (ML20309B074) 392 Beltran, Carlos Email (ML20281A553) 393 Bennett, Terrence Email (ML20210M393) 394 Berland, Paul www.regulations.
gov (ML20281A523) 395 Bernard, Larry San Diego Mission Email (ML20309B074) 396 Best, Alynda Email (ML20301A002)
Page 45 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 47 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 397 Best, Alynda Meeting Transcript (ML20297A255) 398 Bezansib, David Email (ML20170A498) 399 Blackburn, Stephan Meeting Transcript (ML20288A206) 400 Blanco, Arturo Environmental Protection Agency Email (ML20244A136) 401 Bookster, John Meeting Transcript (ML20297A255) 402 Bosold, Patrick Meeting Transcript (ML20288A242) 403 Boudart, Jan Meeting Transcript (ML20288A206) 404 Boudart, Jan Meeting Transcript (ML20288A242) 405 Boudart, Jan Meeting Transcript (ML20297A255)
Page 46 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 48 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 406 Bouquin, David Email (ML20308A921) 407 Bowdey, Lisa Email (ML20309A006) 408 Bowman, Phyllis Email (ML20309A337) 409 Braden, Al Email (ML20254A326) 410 Braden, Al Meeting Transcript (ML20297A255) 411 Brechin, Vernon Email (ML20301A888) 412 Brook, Molly Meeting Transcript (ML20288A206) 413 Brown, Marty San Luis Obispo Mothers for Peace Email (ML20308A799) 414 Brown, Norman Patrick Indigenous Rights Center.Org Email (ML20309B074)
Page 47 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 49 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 415 Buchser, John Rio Grande Chapter of the Sierra Club Email (ML20309B104) 416 Bula, Dale Meeting Transcript (ML20294A435) 417 Burling, Hannah League of Women Voters New Mexico Email (ML20309A990) 418 Burnam, Lon Meeting Transcript (ML20288A206) 419 Burnam, Lon Meeting Transcript (ML20288A242) 420 Burnam, Lon Meeting Transcript (ML20294A435) 421 Burnam, Lon Lone Star Chapter of the Sierra Club Meeting Transcript (ML20297A255) 422 Burnam, Lon Tarrant Coalition for Environmental Awareness Email (ML20309B074) 423 Burns, Terry Sierra Club, Alamo Group of Lone Star Chapter Email (ML20307A135)
Page 48 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 50 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 424 Burns, Terry Sierra Club, Alamo Group of Lone Star Chapter Meeting Transcript (ML20288A242) 425 Caldwell, Brian Email (ML20307A218) 426 Campbell, Bruce Email (ML20346A483) 427 Canestaro-Garcia, Alice Energía Mía Email (ML20309B074) 428 Cantu, Rodrigo Lone Star Legal Aid Email (ML20309B0) 429 Carpenter, Amy Email (ML20309A168) 430 Carr, Melody Email (ML20254A320) 431 Cassidy, T Email (ML20305A321) 432 Castor, Edward www.regulations.
gov (ML20294A407)
Page 49 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 51 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 433 Cato, Mary www.regulations.
gov (ML20226A161) 434 Clark, Peter Indigenous Rights Center.Org Email (ML20309B074) 435 Coenen, Rod Email (ML20280A076) 436 Coghlan, Jay Nuclear Watch New Mexico Email (ML20309B074) 437 Coghlan, Jay Nuclear Watch New Mexico Email (ML20323A202) 438 Collonge, Pegasus NevadaDesert Experience.or g
Email (ML20309B074) 439 Cook, Richard Email (ML20280B085) 440 Cooke, David City of Fort Worth Email (ML20306A364) 441 Cordova, Tina Tularosa Basin Downwinders Consortium Email (ML20309B074)
Page 50 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 52 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 442 Cortez, Loyd Email (ML20254A321) 443 Cortez, Norma Email (ML20281A817) 444 Croom, Carolyn Email (ML20280B050) 445 Croom, Carolyn Meeting Transcript (ML20288A206) 446 Croom, Carolyn Meeting Transcript (ML20294A435) 447 Crow, Caroline Caring for Pasadena Communities Meeting Transcript (ML20294A435) 448 Crow, Caroline Lone Star Legal Aid Email (ML20309B0) 449 Currens, Leslie Email (ML20163A560) 450 D'Arrigo, Diane Meeting Transcript (ML20288A242)
Page 51 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 53 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 451 D'Arrigo, Diane Nuclear Information and Resource Service Email (ML20309B069) 452 D'Arrigo, Diane Nuclear Information and Resource Service Meeting Transcript (ML20288A206) 453 D'Arrigo, Diane Nuclear Information and Resource Service Meeting Transcript (ML20297A255) 454 Daniel, Theresa Dallas
- County, Texas Email (ML20309A029) 455 Daniel, Theresa Dallas
- County, Texas Meeting Transcript (ML20297A255) 456 Davidson, Jill www.regulations.
gov (ML20268B803) 457 Davis, Edward U.S. Nuclear Industry Council Meeting Transcript (ML20288A206) 458 Deerinwater, Jesse Citizens' Resistance at Fermi 2 Meeting Transcript (ML20288A206) 459 Dinn, Amy Lone Star Legal Aid Email (ML20309B0)
Page 52 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 54 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 460 Douglas, Karen League of Women Voters, New Mexico Meeting Transcript (ML20288A242) 461 Drake, Tiffany Missouri Department of Natural Resources Email (ML20301A066) 462 Drey, Kay Beyond Nuclear Email (ML20284A365) 463 Drey, Kay Beyond Nuclear Email (ML20284A366) 464 Drey, Kay Beyond Nuclear Email (ML20284A367) 465 Drey, Kay Beyond Nuclear Email (ML20284A368) 466 Drey, Kay Beyond Nuclear Email (ML20285A065) 467 Drey, Kay Beyond Nuclear Email (ML20285A068) 468 Drey, Kay Beyond Nuclear Email (ML20290A008)
Page 53 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 55 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 469 Drey, Kay Beyond Nuclear Email (ML20290A009) 470 Drey, Kay Beyond Nuclear Email (ML20300A183) 471 Drey, Kay Beyond Nuclear Email (ML20301A098) 472 Drey, Kay Beyond Nuclear Email (ML20301A187) 473 Drey, Kay Beyond Nuclear Email (ML20301A191) 474 Drey, Kay Beyond Nuclear Email (ML20301A208) 475 Drey, Kay Beyond Nuclear Email (ML20301A213) 476 Drey, Kay Beyond Nuclear Email (ML20301A220) 477 Drey, Kay Beyond Nuclear Email (ML20309A964)
Page 54 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 56 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 478 Drey, Kay Beyond Nuclear Email (ML20309B013) 479 Drey, Kay Beyond Nuclear Email (ML20309B074) 480 Drey, Kay Beyond Nuclear Email (ML20309B078) 481 Drey, Kay Beyond Nuclear Email (ML20309B080) 482 Drey, Kay Beyond Nuclear Email (ML20309B088) 483 Drey, Kay Beyond Nuclear Email (ML20309B093) 484 Drey, Kay Beyond Nuclear Email (ML20309B119) 485 Dunzik-Gougar, Mary Lou American Nuclear Society www.regulations.
gov (ML20281A524) 486 Eastland, Mike North Central Texas Council of Governments www.regulations.
gov (ML20308A421)
Page 55 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 57 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 487 Eckhardt, Sarah State of Texas Email (ML20303A292) 488 Edlow, Jack Edlow International Company Meeting Transcript (ML20288A206) 489 Eichelberger, Don www.regulations.
gov (ML20297A250) 490 Eichelberger, Don Abalone Alliance SEC Meeting Transcript (ML20294A435) 491 Eiser, Jay Email (ML20300A097) 492 Evans, Amanda Email (ML20346A458) 493 Evans, William Email (ML20254A335) 494 Eyles, Evelyn Email (ML20346A476) 495 Faidley, Richard Meeting Transcript (ML20297A255)
Page 56 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 58 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 496 Fay, Jacquelyn Email (ML20298A326) 497 Feil, Kim Email (ML20219A663) 498 Fleming, Melissa Email (ML20160A448) 499 Ford, Aaron State of Nevada Email (ML20309A959) 500 Fronzak, Robert America Association of Railroads www.regulations.
gov (ML20192A001) 501 Gannaway, Timothy Meeting Transcript (ML20294A435) 502 Gannaway, Timothy Meeting Transcript (ML20297A255) 503 Garcia, Janet Meeting Transcript (ML20297A255) 504 Gardner, Rose Email (ML20176A481)
Page 57 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 59 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 505 Gardner, Rose Meeting Transcript (ML20288A206) 506 Gardner, Rose Meeting Transcript (ML20288A242) 507 Gardner, Rose Meeting Transcript (ML20294A435) 508 Gardner, Rose Meeting Transcript (ML20297A255) 509 Gardner, Rose Alliance for Environmental Strategies Email (ML20309B074) 510 Geiger, Doreen Meeting Transcript (ML20288A206) 511 Gellert, Sally Jane Email (ML20170B322) 512 Gendron, Marilyn Email (ML20309B056) 513 Gentile, Allison Email (ML20301A852)
Page 58 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 60 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 514 Germano, Jennifer Email (ML20309A994) 515 Getchell, Lynette Email (ML20298A508) 516 Gewax, Lisa www.regulations.
gov (ML20248H322) 517 Gibson, Claudia www.regulations.
gov (ML20133K148) 518 Gibson, Kenneth Email (ML20298A358) 519 Gilmore, Donna Email (ML20279A820) 520 Goldstein, Bridget Meeting Transcript (ML20288A242) 521 Goodwin, Vikki Texas State Government Email (ML20294A263) 522 Gordon, Rick Email (ML20284A338)
Page 59 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 61 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 523 Gordon, Susan Multicultural Alliance for a Safe Environment Email (ML20309B074) 524 Gorman, Pam Xcel Energy Meeting Transcript (ML20294A435) 525 Gosslee, Susybelle Texas League of Women Voters Meeting Transcript (ML20288A206) 526 Gould, Robert Physicians for Social Responsibility Meeting Transcript (ML20297A255) 527 Gray, Erica Meeting Transcript (ML20297A255) 528 Greenwald, Janet Citizens for Alternatives to Radioactive Dumping Email (ML20309B074) 529 Greenwald, Janet Citizens for Alternatives to Radioactive Dumping Email (ML20309B115) 530 Greenwald, Janet Citizens for Alternatives to Radioactive Dumping Meeting Transcript (ML20294A435) 531 Grisham, Michelle Lujan State of New Mexico Email (ML20309B135)
Page 60 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 62 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 532 Guldi, Christine www.regulations.
gov (ML20211M134) 533 Gundersen, Margaret Fairewinds Energy Education Email (ML20346A482) 534 Haase, Daniel www.regulations.
gov (ML20227A344) 535 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Email (ML20224A364) 536 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Email (ML20309A003) 537 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Email (ML20309B074) 538 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Email (ML20309B086)
Page 61 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 63 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 539 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Meeting Transcript (ML20288A206) 540 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Meeting Transcript (ML20288A242) 541 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Meeting Transcript (ML20294A435) 542 Hadden, Karen Sustainable Energy &
Economic Development (SEED)
Coalition Meeting Transcript (ML20297A255) 543 Hall, Joyce Email (ML20282A635) 544 Halpin, Beki Email (ML20281A930) 545 Halpin, Beki Meeting Transcript (ML20288A206) 546 Halpin, Beki Meeting Transcript (ML20294A435)
Page 62 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 64 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 547 Halpin, Richard Meeting Transcript (ML20288A206) 548 Halpin, Richard Austin Texas Green Sanctuary Ministry Email (ML20280B005) 549 Halpin, Richard Austin Texas Green Sanctuary Ministry Meeting Transcript (ML20294A435) 550 Hancock, Don Southwest Research and Information Center Email (ML20309B074) 551 Hanratty, Linda Meeting Transcript (ML20288A242) 552 Hanson, Richard Texas Parks and Wildlife Department Email (ML20301A204) 553 Harmon, Lucy Email (ML20279A828) 554 Harrison, Dan Email (ML20280A904) 555 Hartline, Steven www.regulations.
gov (ML20224A467)
Page 63 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 65 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 556 Hendon, Peggy League of Women Voters of Tarrant County Email (ML20285A066) 557 Hendricks, Bob Meeting Transcript (ML20297A255) 558 Henry, Howard Email (ML20309B043) 559 Hersher, Kelsey Meeting Transcript (ML20297A255) 560 Hisasue, Carole San Luis Obispo Mothers for Peace Email (ML20308A799) 561 Hoffman, Ace Email (ML20305A421) 562 Hogan, Frances Email (ML20346A468) 563 Holder, Elaine San Luis Obispo Mothers for Peace Email (ML20308A799) 564 Holland, Brooke Meeting Transcript (ML20297A255)
Page 64 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 66 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 565 Howard, Donna Texas State Repre-sentative Email (ML20309A652) 566 Hughes, Ed Meeting Transcript (ML20297A255) 567 Hughes, Ed Northeast New Mexicans United Against Nuclear Waste Email (ML20309B074) 568 Hughes, Patty Northeast New Mexicans United Against Nuclear Waste Email (ML20309B074) 569 Hyde, Bridget Meeting Transcript (ML20294A435) 570 Hyde, Bridget Meeting Transcript (ML20297A255) 571 Inowei, Marie Meeting Transcript (ML20288A242) 572 Inserra, Marie Email (ML20301A082)
Page 65 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 67 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 573 Isakson, Jeffery TN America LLC Email (ML20220A064) 574 Israel, Celia State of Texas Email (ML20308A897) 575 Jagiello, Carol Email (ML20300A367) 576 Jagiello, Carol Email (ML20307A154) 577 Jaques, Karen Email (ML20297A598) 578 Jenkins, Lyn Email (ML20281A729) 579 Jenkins, Rose Email (ML20168A498) 580 Johnson, Diane www.regulations.
gov (ML20290A289) 581 Johnson, Jan League of Women Voters of Denton Email (ML20309B108)
Page 66 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 68 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 582 Johnson, Molly San Luis Obispo Mothers for Peace Email (ML20308A799) 583 Johnson, Molly San Luis Obispo Mothers for Peace Meeting Transcript (ML20297A255) 584 Johnson, Ron Tribal Radioactive Materials Transpor-tation Committee www.regulations.
gov (ML20309A406) 585 Kamps, Kevin Email (ML20254A305) 586 Kamps, Kevin Email (ML20297A201) 587 Kamps, Kevin Meeting Transcript (ML20294A435) 588 Kamps, Kevin Beyond Nuclear Email (ML20190A044) 589 Kamps, Kevin Beyond Nuclear Email (ML20284A365) 590 Kamps, Kevin Beyond Nuclear Email (ML20284A366)
Page 67 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 69 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 591 Kamps, Kevin Beyond Nuclear Email (ML20284A367) 592 Kamps, Kevin Beyond Nuclear Email (ML20284A368) 593 Kamps, Kevin Beyond Nuclear Email (ML20285A051) 594 Kamps, Kevin Beyond Nuclear Email (ML20285A065) 595 Kamps, Kevin Beyond Nuclear Email (ML20285A068) 596 Kamps, Kevin Beyond Nuclear Email (ML20290A008) 597 Kamps, Kevin Beyond Nuclear Email (ML20290A009) 598 Kamps, Kevin Beyond Nuclear Email (ML20300A183) 599 Kamps, Kevin Beyond Nuclear Email (ML20301A098)
Page 68 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 70 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 600 Kamps, Kevin Beyond Nuclear Email (ML20301A187) 601 Kamps, Kevin Beyond Nuclear Email (ML20301A191) 602 Kamps, Kevin Beyond Nuclear Email (ML20301A208) 603 Kamps, Kevin Beyond Nuclear Email (ML20301A213) 604 Kamps, Kevin Beyond Nuclear Email (ML20301A220) 605 Kamps, Kevin Beyond Nuclear Email (ML20309A964) 606 Kamps, Kevin Beyond Nuclear Email (ML20309B013) 607 Kamps, Kevin Beyond Nuclear Email (ML20309B067) 608 Kamps, Kevin Beyond Nuclear Email (ML20309B074)
Page 69 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 71 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 609 Kamps, Kevin Beyond Nuclear Email (ML20309B078) 610 Kamps, Kevin Beyond Nuclear Email (ML20309B080) 611 Kamps, Kevin Beyond Nuclear Email (ML20309B086) 612 Kamps, Kevin Beyond Nuclear Email (ML20309B088) 613 Kamps, Kevin Beyond Nuclear Email (ML20309B093) 614 Kamps, Kevin Beyond Nuclear Email (ML20309B119) 615 Kamps, Kevin Beyond Nuclear Email (ML20317A281) 616 Kamps, Kevin Beyond Nuclear Meeting Transcript (ML20288A206) 617 Kamps, Kevin Beyond Nuclear Meeting Transcript (ML20288A242)
Page 70 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 72 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 618 Kamps, Kevin Beyond Nuclear Meeting Transcript (ML20297A255) 619 Keegan, Michael Don't Waste Michigan Meeting Transcript (ML20288A242) 620 Kellie, Susan Email (ML20309A557) 621 Kenner, Kate Email (ML20307A159) 622 Kenney, James C.
New Mexico Environment Department Email (ML20309B065) 623 Kern, The Rev Dr Edward Email (ML20280A971) 624 Kipen, Ethel Email (ML20279A868) 625 Kipen, Ken Email (ML20279A868) 626 Klein, James Email (ML20200A002)
Page 71 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 73 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 627 Klein, James Email (ML20284A345) 628 Kleuskens, Tanya Meeting Transcript (ML20288A242) 629 Kleuskens, Tonya Email (ML20309B110) 630 Koch, Cindy www.regulations.
gov (ML20234A539) 631 Koerber, Ellen Email (ML20307A421) 632 Kovac, Scott Nuclear Watch New Mexico Email (ML20323A202) 633 Kraft, David Nuclear Energy Information Service Meeting Transcript (ML20297A255) 634 Kraft, David Nuclear Energy Information Service www.regulations.
gov (ML20308A732) 635 Kurland, Miriam Email (ML20279A830)
Page 72 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 74 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 636 Lambert, Jerell Email (ML20297A111) 637 Latona, Kay Email (ML20280A891) 638 Lawrence, George Email (ML20289B027) 639 Lee, Marc www.regulations.
gov (ML20220A311) 640 Lee, Michel Council on Intelligent Energy &
Conservation Policy and Promoting Health and Sustainable Energy Email (ML20309B068) 641 Lee, Michel Legal Environmental Action Fund Email (ML20309B068) 642 Lee, Michelle Meeting Transcript (ML20288A206)
Page 73 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 75 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 643 Lee, Michelle Meeting Transcript (ML20297A255) 644 Letson, Sonya Email (ML20308A366) 645 Lewis, Sherry San Luis Obispo Mothers for Peace Email (ML20308A799) 646 Lewison, Linda Meeting Transcript (ML20288A206) 647 Limberg, Kim Email (ML20346A497) 648 Littlejohn, Nick Email (ML20281A870) 649 Lodge, Terry On behalf of:
Multiple Organizations Email (ML20309B038)
Page 74 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 76 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 650 Lodge, Terry Sustainable Energy and Economic Development Coalition Meeting Transcript (ML20294A435) 651 Logan, Christopher Email (ML20219A680) 652 Lukasiewicz, Judy Email (ML20174A474) 653 Lyons, Alejandría SouthWest Organizing Project Email (ML20309B074) 654 M, Terissa Email (ML20284A039) 655 Macfarlane, John Email (ML20281A909) 656 MacKenzie, Therese Email (ML20305A112)
Page 75 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 77 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 657 Marida, Patricia Email (ML20309B098) 658 Mathis, Marilyn Email (ML20309A347) 659 Mayers, Kenneth Veterans For Peace Santa Fe Chapter Email (ML20309B074) 660 McCole, Jamy Black www.regulations.
gov (ML20290A896) 661 McCoy, David Citizen Action New Mexico Email (ML20309B004) 662 McCoy, David Citizen Action New Mexico Email (ML20309B074) 663 McCoy, David Citizen Action New Mexico Meeting Transcript (ML20288A206)
Page 76 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 78 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 664 McCoy, David Citizen Action New Mexico Meeting Transcript (ML20288A242) 665 McCullum, Rod Meeting Transcript (ML20288A242) 666 McCullum, Rod Meeting Transcript (ML20294A435) 667 McCullum, Rodney Nuclear Energy Institute Email (ML20308A908) 668 McDill, Teresa New Mexico Environment Department Meeting Transcript (ML20297A255) 669 McGuire, Meredith Email (ML20200A004) 670 McGuire, Meredith Meeting Transcript (ML20288A206)
Page 77 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 79 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 671 McManemy, Victor Citizens for Alternatives to Chemical Contamin-ation Meeting Transcript (ML20297A255) 672 McMurrian, Katrina Nuclear Waste Strategy Coalition (NWSC)
Email (ML20309B042) 673 McMurrian, Katrina Nuclear Waste Strategy Coalition (NWSC)
Meeting Transcript (ML20294A435) 674 McNairn, Bonnie Email (ML20309B002) 675 McSweeney, Charles Email (ML20280B086) 676 Melton, Kathryn Email (ML20280A119) 677 Merritt, Fred Email (ML20309B039) 678 Michetti, Susan Meeting Transcript (ML20288A206)
Page 78 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 80 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 679 Mitchell, Cheryl Email (ML20307A199) 680 Montgomery, Bruce Nuclear Energy Institute Meeting Transcript (ML20297A255) 681 Morey, Sandra Email (ML20296A493) 682 Morgan, Leona Email (ML20309B038) 683 Morgan, Leona Diné No Nukes Email (ML20309B074) 684 Morgan, Leona Nuclear Issues Study Group Meeting Transcript (ML20297A255) 685 Mowery, Zac www.regulations.
gov (ML20294A405) 686 Mulcihy, David Email (ML20210M399) 687 Murphy, Deborah Email (ML20282A695)
Page 79 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 81 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 688 Murphy, Patricia Meeting Transcript (ML20288A242) 689 Nabi, Joy Email (ML20301A112) 690 Nazor, Craig Lone Star Chapter Sierra Club Meeting Transcript (ML20297A255) 691 Neeley, Charles www.regulations.
gov (ML20290A288) 692 Nesbit, Steve American Nuclear Society Meeting Transcript (ML20294A435) 693 Newton-Grayson, Diana www.regulations.
gov (ML20224A466) 694 Nicolai, Michael Email (ML20309B075) 695 Nieman, Bryce Keller Independent School District Meeting Transcript (ML20297A255) 696 Norwood, Nancy San Luis Obispo Mothers for Peace Email (ML20308A799)
Page 80 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 82 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 697 O'Brien, Kathy Email (ML20309A280) 698 O'Donnell, Richard Email (ML20210M394) 699 O'Neill, Patrick www.regulations.
gov (ML20302A009) 700 O'Shaughnessy, Eileen Nuclear Issues Study Group Email (ML20309B074) 701 O'Shaughnessy, Eileen Nuclear Issues Study Group Meeting Transcript (ML20297A255) 702 Oder, Steve Email (ML20210M389) 703 Orkin, Jenna Email (ML20210M398) 704 Ottmer, Tammy Colorado State Patrol www.regulations.
gov (ML20309A400) 705 Pachlhofer, Aaron Email (ML20309B100)
Page 81 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 83 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 706 Padilla, Elizabeth Meeting Transcript (ML20288A206) 707 Padilla, Elizabeth Meeting Transcript (ML20297A255) 708 Padilla, Elizabeth Save Andrews County Email (ML20309B074) 709 Papas, Timothea Meeting Transcript (ML20288A206) 710 Parry, Ronald Email (ML20309B107) 711 Patrie, Lewis Email (ML20163A565) 712 Pearce, Susan Email (ML20346A488) 713 Perales, Monica Fasken Oil and Ranch Meeting Transcript (ML20297A255) 714 Peterson, Gordon Email (ML20281A702)
Page 82 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 84 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 715 Pezzati, Mark Email (ML20304A636) 716 Poole, Steve Meeting Transcript (ML20288A242) 717 Preston, David Email (ML20302A169) 718 Price, Betsy City of Fort Worth Email (ML20306A364) 719 Pritikin, Joshua www.regulations.
gov (ML20133K149) 720 Propst, Sarah New Mexico
- Energy, Minerals and Natural Resources Department Email (ML20309B052) 721 Proska, Margo and Dennis Email (ML20309B010) 722 Pyle, Alexandra Email (ML20309A084)
Page 83 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 85 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 723 Ramsay, Rebecca Meeting Transcript (ML20294A435) 724 Ramsay, Rebecca www.regulations.
gov (ML20268B231) 725 Ratcliff, Philip Email (ML20163A559) 726 Reade, Deborah Email (ML20308A937) 727 Reed, Cyrus Email (ML20280B000) 728 Reed, Cyrus Sierra Club, Lone Star Chapter Meeting Transcript (ML20297A255) 729 Resnikoff, Marvin Radioactive Waste Management Associates www.regulations.
gov (ML20276A227) 730 Resnikoff, Marvin Radioactive Waste Management Associates www.regulations.
gov (ML20281A521) 731 Rhodes, Suzanne League of Women Voters Email (ML20298A249)
Page 84 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 86 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 732 Richey, Sharon Meeting Transcript (ML20288A206) 733 Richey, Sharon Meeting Transcript (ML20294A435) 734 Richter, Mark Nuclear Energy Institute Meeting Transcript (ML20288A206) 735 Roberts, Duane Email (ML20281A471) 736 Rodriquez, Eddie Texas State Representa-tive Email (ML20308A440) 737 Romo, Jacqueline www.regulations.
gov (ML20290A892) 738 Rosen, David Email (ML20280A083) 739 Rosen, David Meeting Transcript (ML20288A242) 740 Rosen, David Meeting Transcript (ML20297A255)
Page 85 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 87 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 741 Ruebelmann, Lorna Email (ML20309B023) 742 Sachs, Gary Email (ML20346A467) 743 Samson, Hannah Texas RioGrande Legal Aid Email (ML20309B0) 744 Sargent, Barbara www.regulations.
gov (ML20211M132) 745 Sauber, Michael Email (ML20309A995) 746 Sayre, Johannes Email (ML20232A069) 747 Schmalz, Charles Email (ML20299A067) 748 Schuurman, Susan Nuclear Issues Study Group Email (ML20300A459) 749 Schuurman, Susan Nuclear Issues Study Group Meeting Transcript (ML20297A255)
Page 86 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 88 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 750 Schwartz, Marge www.regulations.
gov (ML20211M133) 751 Seamster, Teresa Email (ML20309A678) 752 Seeley, Linda San Luis Obispo Mothers for Peace Email (ML20308A799) 753 Seyb, Cynthia Email (ML20309A677) 754 Shaffer, Tria Email (ML20280A043) 755 Shelley, Adrian Public Citizen Texas Office Email (ML20309B074) 756 Shelley, Adrian Public Citizen Texas Office Email (ML20309B086) 757 Shelley, Adrian Public Citizen Texas Office Meeting Transcript (ML20288A242) 758 Shepperd, Ben Permian Basin Petroleum Association Email (ML20220A468)
Page 87 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 89 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 759 Simpson, Robert Email (ML20172A254) 760 Simpson, Robert Email (ML20299A298) 761 Sinett, Audrey Meeting Transcript (ML20288A206) 762 Singleton, James www.regulations.
gov (ML20290A293) 763 Singleton, Robert Meeting Transcript (ML20288A206) 764 Singleton, Robert Meeting Transcript (ML20288A242) 765 Singleton, Robert Meeting Transcript (ML20294A435) 766 Singleton, Robert Meeting Transcript (ML20294A435) 767 Singleton, Robert Meeting Transcript (ML20297A255)
Page 88 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 90 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 768 Siwik, Allyson Gila Resources Information Project Email (ML20309B073) 769 Smith, David Email (ML20281A881) 770 Smith, Edward www.regulations.
gov (ML20294A397) 771 Smith, Jan Email (ML20280A985) 772 Smith, Roger Email (ML20307A747) 773 Smith, Tom Email (ML20309B130) 774 Smith, Tom Meeting Transcript (ML20288A206) 775 Smith, Tom Meeting Transcript (ML20288A242) 776 Smith, Tom Meeting Transcript (ML20294A435)
Page 89 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 91 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 777 Smyke, Pete Email (ML20170A386) 778 Soria, Sandra Meeting Transcript (ML20294A435) 779 Spencer, Dave Email (ML20299A117) 780 Sperry, Carolyn Email (ML20346A443) 781 Stein, Cletus The Peace Farm Email (ML20309B074) 782 Stein, Gerald Email (ML20280B090) 783 Stewart, Carol Email (ML20234A570) 784 Suellentrop, Ann Peaceworks Meeting Transcript (ML20294A435) 785 Summer, Rebecca Email (ML20309B109)
Page 90 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 92 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 786 Summer, Rebecca Email (ML20309B112) 787 Sutton, Patrice Physicians for Social Responsibility Meeting Transcript (ML20297A255) 788 Swanson, Jane San Luis Obispo Mothers for Peace Email (ML20308A799) 789 Talarek, Stephanie Physicians for Social Responsibility Email (ML20300A412) 790 Tapang, Pamie Meeting Transcript (ML20297A255) 791 Tasian, Diane League of Women Voters of Dallas Email (ML20309B055) 792 Tate, John Meeting Transcript (ML20294A435) 793 Taylor, Wallace Sierra Club Email (ML20307A480) 794 Taylor, Wallace Sierra Club Nuclear Free Campaign Email (ML20309B074)
Page 91 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 93 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 795 Taylor, Wally Sierra Club Meeting Transcript (ML20288A242) 796 Thomas, Jay TM Americas Meeting Transcript (ML20288A206) 797 Thomas, Jay TN Americas Meeting Transcript (ML20297A255) 798 Tinney, Herbert and Carolyn Email (ML20280A055) 799 Tomlinson, John Email (ML20231A759) 800 Treichel, Judy Nevada Nuclear Waste Task Force Email (ML20301A150) 801 Treichel, Judy Nevada Nuclear Waste Task Force Email (ML20309B074) 802 Trester, Elliot Physicians for Social Responsibility Meeting Transcript (ML20297A255) 803 Tu, Yenter No Borders Communicatio n
Meeting Transcript (ML20297A255)
Page 92 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 94 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 804 Turnbull, Clay New England Coalition Email (ML20309B090) 805 Valdivia, Enrique Texas RioGrande Legal Aid Email (ML20309B0) 806 Valentine, Jennifer www.regulations.
gov (ML20266G387) 807 Valenzano, Mike TN Americas Meeting Transcript (ML20294A435) 808 Van Norman, Janet Email (ML20301A179) 809 Vann II, Robert Email (ML20307A384) 810 Vann II, Robert Email (ML20346A463) 811 Vann II, Robert Meeting Transcript (ML20288A242) 812 Vescovi, Peter Orano Meeting Transcript (ML20288A242)
Page 93 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 95 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 813 Videen, Tom Email (ML20309A986) 814 Villegas, Lorraine Meeting Transcript (ML20297A255) 815 Walker, Kalene Meeting Transcript (ML20297A255) 816 Wallace, Cathy Email (ML20280B051) 817 Wallace, Kathy Meeting Transcript (ML20288A206) 818 Walter, Patricia Meeting Transcript (ML20288A206) 819 Warner, Janet Wheeler Peak Progressives Email (ML20309B074) 820 Warren, Barbara Meeting Transcript (ML20297A255) 821 Warren, Barbara Citizens' Environmental Coalition Email (ML20309A947)
Page 94 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 96 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 822 Wasgatt, Ann Email (ML20210M388) 823 Wassenich, Linda Email (ML20308A235) 824 Watchempino, Laura Email (ML20199M416) 825 Watchempino, Laura Email (ML20325A261) 826 Weehler, Cynthia Meeting Transcript (ML20288A206) 827 Weehler, Cynthia Meeting Transcript (ML20294A435) 828 Wells, Robert Email (ML20210M400) 829 Wild, Kathryn Email (ML20307A728) 830 Wilder, Laura www.regulations.
gov (ML20220A313)
Page 95 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 97 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 831 Wilks, John Veterans For
- Peace, Chapter #63 Email (ML20307A146) 832 Williams, Lori Meeting Transcript (ML20297A255) 833 Williams, Mary Jane Email (ML20300A492) 834 Williams, Mary Jane Meeting Transcript (ML20297A255) 835 Williams, Mary Jane www.regulations.
gov (ML20290A291) 836 Wingeier, Stephen Email (ML20307A716) 837 Young, John Email (ML20281A660) 838 Zabala, Maggie Meeting Transcript (ML20294A435) 839 Zabarte, Ian Native Community Action Council Email (ML20309B041)
Page 96 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 98 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 840 Zabarte, Ian Native Community Action Council Email (ML20309B074) 841 ZamEk, Jill San Luis Obispo Mothers for Peace Email (ML20308A799) 842 Zashin, Elliot www.regulations.
gov (ML20290A286) 843 Zhu, Ling www.regulations.
gov (ML20211M118) 844 Zimmermann, Ron Email (ML20296A417) 845 Multiple commenters - Sponsor of form: NIRS
Subject:
COMMENT on the Draft Environmental Impact Statement (DEIS)
Docket No. 72-1050; NRC-2016-0231 Representative sample of 2,019 form comments received Email (ML20167A140) 846 Multiple commenters - Sponsor of form: SEED
Subject:
Halt the license for radioactive waste storage Representative sample of 247 form comments received Email (ML20189A292)
PUBLIC COMMENTS ON DRAFT ENVIRONMENTAL IMPACT STATEMENT (FORM)
Page 97 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 99 of 100
RECORD ID DOCUMENT DESCRIPTION DOCUMENT DATE ACCESSION NUMBER 847 Multiple commenters - Sponsor of form: Nukebusters
Subject:
Nuclear Transport and Storage Representative sample of 5 form comments received Email (ML20199F496) 848 Multiple commenters - Sponsor of form: Nukebusters
Subject:
Comment to US Nuclear Regulatory Commission on DEIS for WCS ISP CISF Representative sample of 2,044 form comments received Email (ML20230A427) 849 Multiple commenters - Sponsor of form: Sierra Club
Subject:
Docket
Reference:
NRC-2016-0231 Don?t dump on Texas --
Deny the radioactive waste storage license Representative sample of 672 form comments received Email (ML20279A818) 850 Multiple commenters - Sponsor of form: Public Citizen
Subject:
No nuclear waste in Texas Representative sample of 2,754 form comments received Email (ML20288A842) 851 Multiple commenters - Sponsor of form: NIRS
Subject:
Docket NRC 2020-0065 Transfer of VLL (Radioactive) Waste to Exempt Persons for Disposal Representative sample of 9 form comments received Email (ML20303A280) 852 Multiple commenters - Sponsor of form: NIRS
Subject:
Draft Environmental Impact Statement (DEIS), Docket No. 72-1050; NRC-2016-0231 Representative sample of 2,382 form comments received Email (ML20304A233) 853 Multiple commenters - Sponsor of form: SEED
Subject:
No nuclear waste Representative sample of 12 form comments received Email (ML20224A363) 854 Multiple commenters -Sponsor of form: Not known.
Subject:
Please Approve the Texas CIS Facility Representative sample of 57 form comments received Email (ML20285A059)
Page 98 of 98 USCA Case #21-1048 Document #1923391 Filed: 11/22/2021 Page 100 of 100