Letter Sequence Other |
---|
EPID:L-2017-NEW-0002, Interim Storage Partners, LLC - Submittal of License Application Revision 2, and Request to Restart Review of Application for Approval of the WCS Cisf (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement, Supplement, Supplement, Supplement
Results
Other: ML19150A559, ML19182A107, ML20071F156, ML20076D696, ML20105A135, ML20105A136, ML20105A137, ML20105A138, ML20105A139, ML20105A173, ML20261H420, ML20269A259, ML21105A785, ML21188A099, ML21188A100, ML21222A214, ML21265A263
|
MONTHYEARML18206A5952018-07-19019 July 2018 Interim Storage Partners, LLC - Submittal of License Application Revision 2, and Request to Restart Review of Application for Approval of the WCS Cisf Project stage: Request ML18267A2142018-08-29029 August 2018, 25 September 2018 Package: Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) Project stage: Request ML18267A2112018-09-25025 September 2018 Memorandum to A. Rivera-Varona Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) Project stage: Meeting ML18310A0692018-11-0606 November 2018 Letter to E. Sanchez Interim Storage Partners' License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrew County, Texas, Dkt. 72-1050-First RAI, Part 1, Physical Security (W/Encl Project stage: RAI ML18320A1842018-11-16016 November 2018 Letter to J. Isakson Interim Storage Partners' License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrews County, Texas, Dkt No. 72-1050 - First RAI, Part 1 (W/Enclosure 1) Project stage: RAI ML18355A9812018-12-21021 December 2018 Notice of Partially Closed Meeting to Discuss Nrc'S RAI, Dated 11/16/2018, Issued in Connection with Nrc'S Review of the License Application for the Proposed Interim Storage Partners (ISP) Consolidated Interim Storage Facility (Cisf) Project stage: Request ML18360A0052018-12-26026 December 2018 Letter to J. Isakson Approval of Interim Storage Partners Request for Withholding Information from Public Disclosure - Waste Control Specialists Consolidated Interim Storage Facility Project stage: Withholding Request Acceptance ML19032A2552019-01-0808 January 2019, 4 February 2019 Package: Memorandum to C. Regan Summary of January 10, 2019, Partially Closed Public Meeting Project stage: Request ML19032A2302019-02-0404 February 2019 Summary of Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the Interim Storage Partner Consolidated Isfs Application for a Facility at Andrews County, Texas (W/Encl. 1&2) Project stage: RAI ML19072A1612019-02-19019 February 2019, 14 March 2019 Summary of February 19, 2019, Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx Project stage: Request ML19065A0192019-03-0606 March 2019 Letter to J. Isakson Interim Storage Partners Llc'S License Application to Construct and Operate the WCS Consolidated Interim Storage Facility, Andrews County, Texas, Docket No. 72.1050 - First Request for RAI Part 2 (W/Enclosure 1) Project stage: RAI ML19072A1562019-03-14014 March 2019 Summary of Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx (W/Encl. 1&2) Project stage: RAI ML19123A0222019-04-0101 April 2019, 3 May 2019 Package: Memorandum to C. Regan Summary of April 11, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: Request ML19126A0682019-04-0303 April 2019, 6 May 2019 Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: Request ML19105B2172019-04-19019 April 2019 Memorandum to C. Regan Summary of March 20, 2019, Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the Interim Storage Partners Consolidated Isf Application (W/Enclosures 1 and 2) Project stage: RAI ML19120A4282019-04-23023 April 2019 Letter to J. Isakson Interim Storage Partners Llc'S License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrews County, Texas, Dkt No. 72-1050 - First RAI (W/Enclosure) Project stage: RAI ML19123A0232019-05-0303 May 2019 Memorandum to C. Regan Summary of April 11, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: RAI ML19126A0662019-05-0606 May 2019 Memorandum to C. Regan Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas (W/Enclosure 1 & 2) Project stage: RAI ML19150A5592019-06-0303 June 2019 Letter to J. Isakson Site Audit Plan for Interim Storage Partners Proposed Application for a Site-Specific License of an Away-from-Reactor Independent Spent Fuel Storage Installation Project stage: Other ML19182A1072019-07-0101 July 2019 Letter to J. Isakson Interim Storage Partners Llc'S Application for a Specific ISFSI for the Waste Control Specialists Consolidated Interim Storage Facility for Spent Nuclear Fuel - Revised Review Schedule Project stage: Other ML19281D8852019-10-10010 October 2019 Memorandum to C. Regan Summary of September 12, 2019, Public Meeting to Discuss Interim Storage Partners Draft Responses to RAI, Dated July 26, 2019, Issued in Connection with NRC Review of the ISP Consolidated Interim Storage Facility Appl Project stage: Draft RAI ML20071F1562020-03-0505 March 2020 Interim Storage Partners, LLC - Affidavit Project stage: Other ML20071F1532020-03-0505 March 2020 Interim Storage Partners, LLC - Supplemental Information in Support of Nrc'S Environmental Review Project stage: Supplement ML20076D6962020-03-11011 March 2020 Interim Storage Partners, LLC - Submittal of Clarifications to Support Nrc'S Continued Review of the Safety Case for the WCS CISF Project stage: Other ML20101P3992020-03-31031 March 2020 Interim Storage Partners, LLC - Submittal of Draft Responses for Several Rals and Associated Document Markups from First Request for Additional Information, Parts 1, 2 and Clarifications Project stage: Draft Request ML20105A1352020-03-31031 March 2020 Enclosure 1 - Affidavits Project stage: Other ML20105A1732020-04-0606 April 2020 Interim Storage Partners, LLC - Affidavits Project stage: Other ML20105A1342020-04-0707 April 2020 Submission of ISP Responses for RAIs and Associated Document Markups from First Request for Additional Information, Parts 2, 3, and 4 Project stage: Request ML20105A1722020-04-0707 April 2020 Interim Storage Partners, LLC - Submittal of Supplemental Information in Support of RAI, Part 3 Project stage: Supplement ML20105A1382020-04-0707 April 2020 Enclosure 7 - SAR Changed Pages Project stage: Other ML20105A1372020-04-0707 April 2020 Enclosure 5 - La Changed Pages Project stage: Other ML20105A1362020-04-0707 April 2020 Enclosure 3 - RAIs and Responses Project stage: Other ML20105A1392020-04-0707 April 2020 Enclosure 8 - Referenced Documents Project stage: Other ML20184A0672020-07-0202 July 2020 NSIR Safety Evaluation Report Notice of Safeguards Document Availability: Waste Consolidated Storage (WCS) Consolidated Interim Storage Facility (CISF) Specific Licensed Independent Spent Fuel Storage Installation (ISFSI) Physical Security Project stage: Approval ML20237F4702020-08-24024 August 2020 Interim Storage Partners, LLC, Submittal of Revision 3 of the License Application for the WCS CISF Project stage: Request ML20261H4202020-09-0202 September 2020 Submission of Revision 4 of the Safety Analysis Report for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Other ML20269A2592020-09-19019 September 2020 Interim Storage Partners, LLC - Revision 5 of the Physical Security Plan, Training and Qualification Plan, and Safeguards Contingency Plan with Updated Cover Sheets, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Other ML21014A0632021-01-14014 January 2021 Interim Storage Partners, LLC - Submittal of Supplemental Information to Support Nrc'S Continued Review of the Safety Case for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Supplement ML21027A1472021-01-27027 January 2021 Supplemental Information Part 2 to Support Nrc'S Continued Review of the Safety Case for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Supplement ML21105A7852021-04-12012 April 2021 Enclosure 5: Wsc Consolidated Interim Storage Facility, Revision 4 to License Application - Public Version Project stage: Other ML21188A0962021-09-13013 September 2021 Interim Storage Partners, Issuance of Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Request ML21188A0972021-09-13013 September 2021 Transmittal Letter, Interim Storage Partners, Issuance of Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Approval ML21188A1002021-09-13013 September 2021 Technical Specifications, Interim Storage Partners, Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Other ML21188A1012021-09-13013 September 2021 Public Final Safety Evaluation Report, Interim Storage Partners, Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Approval ML21188A0992021-09-13013 September 2021 Materials License SNM-2515, Interim Storage Partners, WCS Consolidated Interim Storage Facility ISFSI Project stage: Other ML21222A2142021-09-13013 September 2021 Record of Decision Interim Storage Partners LLC License Application for a Consolidated Interim Storage Facility, Andrews County, Texas Project stage: Other ML21265A2632021-10-21021 October 2021 10-21-21 Letter to the Honorable Greg Abbott, Governor of Texas, from Chairman Hanson Responds to Letter Related to Interim Storage Partners' License Application to Construct and Operate a Consolidated Interim Storage Facility for Spent Nuc Project stage: Other ML22024A1422022-01-24024 January 2022 Request for Amendment to the Part 72 Specific License SNM-2515 for Interim Storage Partners Llc'S WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Request 2019-05-03
[Table View] |
|
---|
Category:Letter
MONTHYEARML23304A1992023-10-30030 October 2023 Letter to Mr. M. Abrams, Mr. R. Baasch, Mr. A. Kanner, Ms. L. Pettit, and Ms. A. Tennis from S. Pertuit No. 21-60743 State of Texas V. NRC, Agency No. 72-1050 ML23044A0022023-02-10010 February 2023 2-10-23 Texas V NRC - Rule 28(j) Letter (Case No. 21-60743) ML22138A3622022-05-26026 May 2022 Approval Letter WCS CISF Amend 1 ML22144A0952022-05-23023 May 2022 5-23-22 New Mexico V. NRC - Letter to Court (10th Cir.)(Case No. 21-9593) ML22084A0272022-03-24024 March 2022 3-24-22 Kanner Letter to Court (DC Cir.)(Case No. 21-1048)(Consolidated) ML22054A2432022-02-23023 February 2022 Acceptance Letter WCS CISF License Amendment Request 1 ML22024A1422022-01-24024 January 2022 Request for Amendment to the Part 72 Specific License SNM-2515 for Interim Storage Partners Llc'S WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 ML21356A5722021-12-20020 December 2021 12-20-21 Letter to Court (DC Cir.)(Case No. 21-1229) ML21341A4812021-11-22022 November 2021 Final Safety Analysis Report (FSAR) for the WCS Consolidated Interim Storage Facility ML21265A2632021-10-21021 October 2021 10-21-21 Letter to the Honorable Greg Abbott, Governor of Texas, from Chairman Hanson Responds to Letter Related to Interim Storage Partners' License Application to Construct and Operate a Consolidated Interim Storage Facility for Spent Nuc ML21281A0932021-10-14014 October 2021 Comments on Final Environmental Impact Statement for Interim Storage Partners Llc'S Proposed Consolidated Interim Storage Facility for Spent Nuclear Fuel, Andrews County, Texas ML21280A3392021-10-14014 October 2021 Response to Jkenney NMED Letter Re Comments on Final Environmental Impact Statement for Interim Storage Partners License Application for a Consolidated Interim Storage Facility ML21242A4062021-09-16016 September 2021 LTR-21-0237, Oedo Response Letter to Tx State Representative Tom Craddick (District 82) Regarding Opposition to Spent Fuel Storage in Texas ML21188A0972021-09-13013 September 2021 Transmittal Letter, Interim Storage Partners, Issuance of Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI ML21258A4022021-09-12012 September 2021 Letter from Michael Ford Re Comments on Final Environmental Impact Statement for Interim Storage Partners' License Application for a Consolidated Interim Storage Facility in Andrews County, Texas ML21258A4042021-09-11011 September 2021 Letter from Permian Basin Coalition of Land and Royalty Owners and Fasken Land and Minerals, Ltd. Re Comments on Final Environmental Impact Statement for Interim Storage Partners' License Application for a Consolidated Interim Storage Facil ML21256A0042021-09-10010 September 2021 Letter from EPA Region 6 Regarding the Final Environmental Impact Statement Related to the Interim Storage Partner'S Consolidated Interim Storage Facility in Andrews County, Texas ML21258A4072021-09-10010 September 2021 Letter from Texas Riogrande Legal Aid Re Comments on Final Environmental Impact Statement for Interim Storage Partners' License Application for a Consolidated Interim Storage Facility in Andrews County, Texas ML21258A3982021-09-0303 September 2021 Letter from Lone Star Legal Aid Re Comments on Final Environmental Impact Statement for Interim Storage Partners' License Application for a Consolidated Interim Storage Facility in Andrews County, Texas ML21225A1632021-08-27027 August 2021 Ltr to the Honorable Jose Menendez, Texas Legislator, from Chairman Hanson Re License Application of Interim Storage Partners LLC, Dkt 72-1050, and License Application of Holtec, Inc., Dkt 72-1051,for a Consolidated Interim Storage Faciliti ML21223A0252021-08-27027 August 2021 Letter to Andrews County Judge Charlie Falcon in Response to Andrews County Resolution Regarding WCS CISF ML21200A1282021-08-11011 August 2021 Final ISP Feis Distribution to Andrews County Library ML21217A2302021-08-11011 August 2021 Final ISP Feis Distibution to Yoakum County Library ML21217A2342021-08-11011 August 2021 Final ISP Feis Distribution to Winkler County Library ML21217A2392021-08-0909 August 2021 Final ISP Feis Distribution to Gaines County Library, Tx ML21217A2412021-08-0909 August 2021 Final ISP Feis Distribution to Eunice Public Library ML21217A2362021-08-0909 August 2021 Final ISP Feis Distibution to Hobbs Public Library ML21209A6032021-07-29029 July 2021 Letter to I. Ramirez of Texas Band of Yaqui Indians Re Notice of Final EIS for ISP CISF License Application ML21209A5772021-07-29029 July 2021 Letter to R. Martin of Tonkawa Tribe of Oklahoma Notice of Final EIS for ISP CISF License Application ML21209A5632021-07-29029 July 2021 Letter to G. Aguilar of Mescalero Apache Tribe Re Notice of Final EIS for ISP CISF License Application ML21209A5662021-07-29029 July 2021 Letter to T. Parton of Wichita and Affiliated Tribes Re Notice of Final EIS for ISP CISF License Application ML21209A5352021-07-29029 July 2021 Letter to Bkomardley of Apache Tribe of Oklahoma Re Notice of Final EIS for ISP CISF License Application ML21209A5572021-07-29029 July 2021 Letter to M. Silvas of Ysleta Del Sur Pueblo Re Notice of Final EIS for ISP CISF License Application ML21204A0262021-07-29029 July 2021 Letter to Mkomalty of Kiowa Tribe of Oklahoma Notice of Final Environmental Impact Statement for Interim Storage Partners License Application ML21209A5612021-07-29029 July 2021 Letter to Wnelson of Comanche Nation Re Notice of Final EIS for ISP CISF License Application ML21200A1242021-07-29029 July 2021 Notice of Availability of the Final Environmental Impact Statement for Interim Storage Partner'S Proposed Consolidated Interim Storage Facility Located in Andrews County, Texas ML21105A7912021-04-12012 April 2021 Interim Storage Partners, LLC, Submittal of Revision 5 of the Safety Analysis Report and Revision 4 of the License Application for the WCS CISF ML21154A2992021-03-23023 March 2021 Fws Updated List of Threatened and Endangered Species for the Proposed ISP CISF ML21036A3092021-02-16016 February 2021 LTR-21-0009-1-NMSS-Letter to the Honorable Michelle Lujan-Grisham, Governor of New Mexico from M. Doane, EDO, Us NRC ML21027A1472021-01-27027 January 2021 Supplemental Information Part 2 to Support Nrc'S Continued Review of the Safety Case for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 ML20307A3102021-01-26026 January 2021 Jpappas Letter - NHPA Section 106 Determination of Effects for Isp'S Proposed CISF ML20308A6052021-01-26026 January 2021 Chairman Nelson of Comanche Nation - NHPA Section 106 Determination of Effects for Isp'S Proposed CISF (3) ML20351A3182021-01-15015 January 2021 Letter to President Martin of the Tonkawa Tribe of Oklahoma ML20350B5052021-01-15015 January 2021 Letter to Chairman Komalty of Kiowa Tribe of Oklahoma (1) ML20351A2282021-01-15015 January 2021 Letter to Chairman Komardley of Apache Tribe of Oklahoma ML20351A3142021-01-15015 January 2021 Letter to President Parton of the Wichita and Affiliated Tribes ML20351A3122021-01-14014 January 2021 Letter to President Aguilar of Mescalero Apache Tribe (1) ML21014A0632021-01-14014 January 2021 Interim Storage Partners, LLC - Submittal of Supplemental Information to Support Nrc'S Continued Review of the Safety Case for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 ML20349A1002020-12-16016 December 2020 Letter to Governor Silvas of Ysleta Del Sur Pueblo (1) ML20307A2582020-12-14014 December 2020 Mwolfe Letter- NHPA Section 106 Consultation for Isp'S Proposed CISF 2023-02-10
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 July 1, 2019 Mr. Jeffrey D. Isakson Chief Executive Officer/President Interim Storage Partners LLC P.O. Box 1129 Andrews, TX 79714
SUBJECT:
INTERIM STORAGE PARTNERS LLCS APPLICATION FOR A SPECIFIC INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE FOR THE WASTE CONTROL SPECIALISTS CONSOLIDATED INTERIM STORAGE FACILITY FOR SPENT NUCLEAR FUEL - REVISED REVIEW SCHEDULE
Dear Mr. Isakson:
By letter dated July 19, 2018 (NRC Agencywide Documents Access and Management System (ADAMS) Accession No. ML18206A595), Interim Storage Partners LLC (ISP), a joint venture of Waste Control Specialists LLC (WCS) and Orano CIS LLC (a subsidiary of Orano USA),
requested that the U.S. Nuclear Regulatory Commission (NRC) resume all safety and environmental review activities associated with the proposed WCS Consolidated Interim Storage Facility (WCS CISF) license application. The NRC staff reviewed your request and concluded that the revised license application provided information sufficient to resume its detailed review and provided a schedule for completing the review on August 21, 2018 (ADAMS Accession No. ML18225A281).
On May 31, 2019 (ADAMS Accession No. ML19156A059), ISP submitted a schedule for responding to the remaining requests for additional information (RAI) in support of the continued review of the WCS CISF License Application. The NRC staff has determined that due to the amount of time ISP has requested for providing responses to the staffs RAI, it will extend its previously established schedule for the review. The schedule for its safety and security review will be revised for staff to complete its final safety evaluation report by May 2021. The schedule for its environmental review will be revised for staff to publish the draft and final environmental impact statement by May 2020, and May 2021, respectively.
As we stated in our previous letter, this revised schedule continues to assume that ISP will provide timely and high-quality RAI responses within 60 days of the receipt of any future RAI letters. In accordance with the guidance in LIC-SFM-26, Operational Strategies and Management Expectations (ML16222A251), RAI responses, which are not received within the agreed-upon time may result in the review being delayed again or suspended. In addition, low-quality RAI responses may be deemed non-responsive and result in the suspension of the review.
J. Isakson If you have any questions regarding these matters, please contact the Project Manager, Mr. John-Chau Nguyen, at (301) 415-0262 or John-Chau.Nguyen@nrc.gov.
Sincerely,
/RA/
John McKirgan, Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1050 CAC/EPID No. 001028/L-2017-NEW-0002
J. Isakson
SUBJECT:
INTERIM STORAGE PARTNERS LLCS APPLICATION FOR A SPECIFIC INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE FOR THE WASTE CONTROL SPECIALISTS CONSOLIDATED INTERIM STORAGE FACILITY FOR SPENT NUCLEAR FUEL - REVISED REVIEW SCHEDULE, DOCUMENT DATE: July 1, 2019 DISTRIBUTION:
JGwo, NMSS DTang, NMSS JSolis, NMSS DBarto, NMSS JChang, NMSS DDunn, NMSS GBjorkman, NMSS JMarcano, NMSS ELove, NMSS TTerry, NMSS KKalman, NMSS JPark, NMSS TWertz, NRR STammara, NRO KMcCullough, NSIR MNorris, NSIR PDoub, NRO RFedors, NRO LCandelario, NRO JThompson, NRO DHeeszel, NRO SJones, NRR DGarner DDiaz-Toro, NMSS ZXi, NRO KErwin, NRO MDudek, NRO JAnderson, NSIR BWatson, NMSS TMossman, NSIR CRoman-Cuevas, NMSS SKoenick, NMSS SKirkwood, OGC DBarnhurst, NRO Sanderson, NRR AMoreno, OCA DMcIntyre,OPA FMiller, NRR RKellar, RIV G:\SFST\Nguyen\Casework\WCS\Technical Review\Restart Technical Review\ISP revised review schedule letter.docx ADAMS P8 Accession No.: ML19182A107 OFFICE: NMSS/SFM NMSS/FCSE NMSS/SFM NMSS/FCSE NMSS/SFM NAME: JNguyen JPark WWheatley CRoman-Cuevas JMcKirgan DATE: 06/26/19 06/26/19 06/28/19 06/28/19 07/01/2019 OFFICIAL RECORD COPY