Letter Sequence RAI |
---|
EPID:L-2017-NEW-0002, Interim Storage Partners, LLC - Submittal of License Application Revision 2, and Request to Restart Review of Application for Approval of the WCS Cisf (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement, Supplement, Supplement, Supplement
Results
Other: ML19150A559, ML19182A107, ML20071F156, ML20076D696, ML20105A135, ML20105A136, ML20105A137, ML20105A138, ML20105A139, ML20105A173, ML20261H420, ML20269A259, ML21105A785, ML21188A099, ML21188A100, ML21222A214, ML21265A263
|
MONTHYEARML18206A5952018-07-19019 July 2018 Interim Storage Partners, LLC - Submittal of License Application Revision 2, and Request to Restart Review of Application for Approval of the WCS Cisf Project stage: Request ML18267A2142018-08-29029 August 2018, 25 September 2018 Package: Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) Project stage: Request ML18267A2112018-09-25025 September 2018 Memorandum to A. Rivera-Varona Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) Project stage: Meeting ML18310A0692018-11-0606 November 2018 Letter to E. Sanchez Interim Storage Partners' License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrew County, Texas, Dkt. 72-1050-First RAI, Part 1, Physical Security (W/Encl Project stage: RAI ML18320A1842018-11-16016 November 2018 Letter to J. Isakson Interim Storage Partners' License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrews County, Texas, Dkt No. 72-1050 - First RAI, Part 1 (W/Enclosure 1) Project stage: RAI ML18355A9812018-12-21021 December 2018 Notice of Partially Closed Meeting to Discuss Nrc'S RAI, Dated 11/16/2018, Issued in Connection with Nrc'S Review of the License Application for the Proposed Interim Storage Partners (ISP) Consolidated Interim Storage Facility (Cisf) Project stage: Request ML18360A0052018-12-26026 December 2018 Letter to J. Isakson Approval of Interim Storage Partners Request for Withholding Information from Public Disclosure - Waste Control Specialists Consolidated Interim Storage Facility Project stage: Withholding Request Acceptance ML19032A2552019-01-0808 January 2019, 4 February 2019 Package: Memorandum to C. Regan Summary of January 10, 2019, Partially Closed Public Meeting Project stage: Request ML19032A2302019-02-0404 February 2019 Summary of Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the Interim Storage Partner Consolidated Isfs Application for a Facility at Andrews County, Texas (W/Encl. 1&2) Project stage: RAI ML19072A1612019-02-19019 February 2019, 14 March 2019 Summary of February 19, 2019, Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx Project stage: Request ML19065A0192019-03-0606 March 2019 Letter to J. Isakson Interim Storage Partners Llc'S License Application to Construct and Operate the WCS Consolidated Interim Storage Facility, Andrews County, Texas, Docket No. 72.1050 - First Request for RAI Part 2 (W/Enclosure 1) Project stage: RAI ML19072A1562019-03-14014 March 2019 Summary of Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx (W/Encl. 1&2) Project stage: RAI ML19123A0222019-04-0101 April 2019, 3 May 2019 Package: Memorandum to C. Regan Summary of April 11, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: Request ML19126A0682019-04-0303 April 2019, 6 May 2019 Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: Request ML19105B2172019-04-19019 April 2019 Memorandum to C. Regan Summary of March 20, 2019, Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the Interim Storage Partners Consolidated Isf Application (W/Enclosures 1 and 2) Project stage: RAI ML19120A4282019-04-23023 April 2019 Letter to J. Isakson Interim Storage Partners Llc'S License Application to Construct and Operate the Waste Control Specialists Consolidated Interim Storage Facility, Andrews County, Texas, Dkt No. 72-1050 - First RAI (W/Enclosure) Project stage: RAI ML19123A0232019-05-0303 May 2019 Memorandum to C. Regan Summary of April 11, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas Project stage: RAI ML19126A0662019-05-0606 May 2019 Memorandum to C. Regan Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas (W/Enclosure 1 & 2) Project stage: RAI ML19150A5592019-06-0303 June 2019 Letter to J. Isakson Site Audit Plan for Interim Storage Partners Proposed Application for a Site-Specific License of an Away-from-Reactor Independent Spent Fuel Storage Installation Project stage: Other ML19182A1072019-07-0101 July 2019 Letter to J. Isakson Interim Storage Partners Llc'S Application for a Specific ISFSI for the Waste Control Specialists Consolidated Interim Storage Facility for Spent Nuclear Fuel - Revised Review Schedule Project stage: Other ML19281D8852019-10-10010 October 2019 Memorandum to C. Regan Summary of September 12, 2019, Public Meeting to Discuss Interim Storage Partners Draft Responses to RAI, Dated July 26, 2019, Issued in Connection with NRC Review of the ISP Consolidated Interim Storage Facility Appl Project stage: Draft RAI ML20071F1562020-03-0505 March 2020 Interim Storage Partners, LLC - Affidavit Project stage: Other ML20071F1532020-03-0505 March 2020 Interim Storage Partners, LLC - Supplemental Information in Support of Nrc'S Environmental Review Project stage: Supplement ML20076D6962020-03-11011 March 2020 Interim Storage Partners, LLC - Submittal of Clarifications to Support Nrc'S Continued Review of the Safety Case for the WCS CISF Project stage: Other ML20101P3992020-03-31031 March 2020 Interim Storage Partners, LLC - Submittal of Draft Responses for Several Rals and Associated Document Markups from First Request for Additional Information, Parts 1, 2 and Clarifications Project stage: Draft Request ML20105A1352020-03-31031 March 2020 Enclosure 1 - Affidavits Project stage: Other ML20105A1732020-04-0606 April 2020 Interim Storage Partners, LLC - Affidavits Project stage: Other ML20105A1342020-04-0707 April 2020 Submission of ISP Responses for RAIs and Associated Document Markups from First Request for Additional Information, Parts 2, 3, and 4 Project stage: Request ML20105A1722020-04-0707 April 2020 Interim Storage Partners, LLC - Submittal of Supplemental Information in Support of RAI, Part 3 Project stage: Supplement ML20105A1382020-04-0707 April 2020 Enclosure 7 - SAR Changed Pages Project stage: Other ML20105A1372020-04-0707 April 2020 Enclosure 5 - La Changed Pages Project stage: Other ML20105A1362020-04-0707 April 2020 Enclosure 3 - RAIs and Responses Project stage: Other ML20105A1392020-04-0707 April 2020 Enclosure 8 - Referenced Documents Project stage: Other ML20184A0672020-07-0202 July 2020 NSIR Safety Evaluation Report Notice of Safeguards Document Availability: Waste Consolidated Storage (WCS) Consolidated Interim Storage Facility (CISF) Specific Licensed Independent Spent Fuel Storage Installation (ISFSI) Physical Security Project stage: Approval ML20237F4702020-08-24024 August 2020 Interim Storage Partners, LLC, Submittal of Revision 3 of the License Application for the WCS CISF Project stage: Request ML20261H4202020-09-0202 September 2020 Submission of Revision 4 of the Safety Analysis Report for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Other ML20269A2592020-09-19019 September 2020 Interim Storage Partners, LLC - Revision 5 of the Physical Security Plan, Training and Qualification Plan, and Safeguards Contingency Plan with Updated Cover Sheets, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Other ML21014A0632021-01-14014 January 2021 Interim Storage Partners, LLC - Submittal of Supplemental Information to Support Nrc'S Continued Review of the Safety Case for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Supplement ML21027A1472021-01-27027 January 2021 Supplemental Information Part 2 to Support Nrc'S Continued Review of the Safety Case for the WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Supplement ML21105A7852021-04-12012 April 2021 Enclosure 5: Wsc Consolidated Interim Storage Facility, Revision 4 to License Application - Public Version Project stage: Other ML21188A0962021-09-13013 September 2021 Interim Storage Partners, Issuance of Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Request ML21188A0972021-09-13013 September 2021 Transmittal Letter, Interim Storage Partners, Issuance of Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Approval ML21188A1002021-09-13013 September 2021 Technical Specifications, Interim Storage Partners, Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Other ML21188A1012021-09-13013 September 2021 Public Final Safety Evaluation Report, Interim Storage Partners, Materials License SNM-2515, WCS Consolidated Interim Storage Facility ISFSI Project stage: Approval ML21188A0992021-09-13013 September 2021 Materials License SNM-2515, Interim Storage Partners, WCS Consolidated Interim Storage Facility ISFSI Project stage: Other ML21222A2142021-09-13013 September 2021 Record of Decision Interim Storage Partners LLC License Application for a Consolidated Interim Storage Facility, Andrews County, Texas Project stage: Other ML21265A2632021-10-21021 October 2021 10-21-21 Letter to the Honorable Greg Abbott, Governor of Texas, from Chairman Hanson Responds to Letter Related to Interim Storage Partners' License Application to Construct and Operate a Consolidated Interim Storage Facility for Spent Nuc Project stage: Other ML22024A1422022-01-24024 January 2022 Request for Amendment to the Part 72 Specific License SNM-2515 for Interim Storage Partners Llc'S WCS CISF, Docket 72-1050 Cac/Epid 001028/L-2017-NEW-0002 Project stage: Request 2019-05-03
[Table View] |
|
---|
Category:Meeting Agenda
MONTHYEARML20287A3142020-10-13013 October 2020 U.S. Nuclear Regulatory Commission to Conduct Public Online Webinar for the Draft Environmental Impact Statement for the Proposed Interim Storage Partners Consolidated Interim Storage Facility ML20281A4032020-10-0707 October 2020 U.S. Nuclear Regulatory Commission to Conduct Public Online Webinar for the Draft Environmental Impact Statement for the Proposed Interim Storage Partners Consolidated Interim Storage Facility ML20279A7002020-10-0505 October 2020 U.S. Nuclear Regulatory Commission to Conduct Public Online Webinar for the Draft Environmental Impact Statement for the Proposed Interim Storage Partners Consolidated Interim Storage Facility ML20274A3452020-09-30030 September 2020 U.S. Nuclear Regulatory Commission to Conduct Public Online Webinar for the Draft Environmental Impact Statement for the Proposed Interim Storage Partners Consolidated Interim Storage Facility ML19284B6212019-10-11011 October 2019 Public Meeting with Interim Storage Partners LLC (ISP) to Discuss Nrc'S Request for Additional Information, Dated 4/23/19, Issued in Connection with Nrc'S Review of the License Application for Proposed ISP Consolidated Interim Storage Facil ML19281D8852019-10-10010 October 2019 Memorandum to C. Regan Summary of September 12, 2019, Public Meeting to Discuss Interim Storage Partners Draft Responses to RAI, Dated July 26, 2019, Issued in Connection with NRC Review of the ISP Consolidated Interim Storage Facility Appl ML19239A2012019-08-27027 August 2019 9-12-19 Notice of Partially Closed Meeting with Interim Storage Partners, LLC (ISP) to Discuss Isp'S Draft Responses to Requests for Additional Information ML19217A1952019-08-0101 August 2019 8/19/2019 Notice of Closed Meeting with Interim Storage Partners, LLC (ISP) to Discuss Isp'S Responses to NRC Staff'S Requests for Additional Information Physical Security Plan for the Waste Control Specialists Consolidated Interim Storage ML19228A2262019-08-0101 August 2019 8/19/2019 Notice of Cancelled Closed Mtg with Interim Storage Partners, (ISP) to Discuss Isp'S Responses to NRC Staff'S Requests for Additional Information Physical Security Plan for the Waste Control Specialists Consolidated Interim Storag ML19094B8612019-04-0404 April 2019 Partially Closed Meeting with Interim Storage Partners (ISP) to Discuss Request for Additional Info. Dated 11/16/2018 Issued in Connection with Nrc'S Review of the License Application for Proposed ISP Consolidated Interim Storage Facility ML19092A1952019-03-28028 March 2019 Partially Closed Meeting with Interim Storage Partners (ISP) to Discuss Request for Additional Info., Dated 11/16/2018, Issued in Connection with Nrc'S Review of License Application for the Proposed ISP Consolidated Interim Storage Facility ML19085A3652019-03-26026 March 2019 Closed Meeting to Discuss Safeguards Information as Required to Address Nrc'S RAI Dated Nov. 6, 2018, Issued in Connection with Nrc'S Review of the License Application for Proposed Interim Storage Partners Consolidated Interim Storage Facil ML19072A1562019-03-14014 March 2019 Summary of Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx (W/Encl. 1&2) ML19066A2732019-03-0707 March 2019 Notice of Meeting with Interim Storage Partners, LLC (ISP) to Discuss Nrc'S RAI, Dated 11/16/18, Issued in Connection with Nrc'S Review of the License Application for the Proposed ISP Consolidated Interim Storage Facility (Cisf) ML19038A4402019-02-0707 February 2019 Notice of Partially Closed Meeting with Interim Storage Partners (ISP) to Discuss Nrc'S Request for Additional Info., Issued in Connection with Nrc'S Review of the License Application for the Proposed Consolidated Interim Storage Facility ML18355A9812018-12-21021 December 2018 Notice of Partially Closed Meeting to Discuss Nrc'S RAI, Dated 11/16/2018, Issued in Connection with Nrc'S Review of the License Application for the Proposed Interim Storage Partners (ISP) Consolidated Interim Storage Facility (Cisf) ML18221A2672018-08-0909 August 2018 Notice of Meeting with Interim Storage Partners (ISP) to Discuss the ISP Consolidated Emergency Response Plan (Cerp) for Its Proposed Consolidated Interim Storage Facility 2020-09-30
[Table view] Category:Meeting Summary
MONTHYEARML19326B2162019-11-22022 November 2019 Summary of October 24, 2019 Meeting with ISP on Draft RAI Responses ML19281D8852019-10-10010 October 2019 Memorandum to C. Regan Summary of September 12, 2019, Public Meeting to Discuss Interim Storage Partners Draft Responses to RAI, Dated July 26, 2019, Issued in Connection with NRC Review of the ISP Consolidated Interim Storage Facility Appl ML19072A1562019-03-14014 March 2019 Summary of Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx (W/Encl. 1&2) ML19032A2302019-02-0404 February 2019 Summary of Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the Interim Storage Partner Consolidated Isfs Application for a Facility at Andrews County, Texas (W/Encl. 1&2) ML18267A2112018-09-25025 September 2018 Memorandum to A. Rivera-Varona Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) 2019-03-14
[Table view] Category:Memoranda
MONTHYEARML19161A1492019-12-12012 December 2019 Memo to C. Roman, Chief; Re., Issuance of Scoping Summary Report for ISP Cisf EIS Project ML19326B2162019-11-22022 November 2019 Summary of October 24, 2019 Meeting with ISP on Draft RAI Responses ML19281D8852019-10-10010 October 2019 Memorandum to C. Regan Summary of September 12, 2019, Public Meeting to Discuss Interim Storage Partners Draft Responses to RAI, Dated July 26, 2019, Issued in Connection with NRC Review of the ISP Consolidated Interim Storage Facility Appl ML19126A0662019-05-0606 May 2019 Memorandum to C. Regan Summary of April 16, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas (W/Enclosure 1 & 2) ML19123A0232019-05-0303 May 2019 Memorandum to C. Regan Summary of April 11, 2019, Partially Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the ISP Consolidated Isf Application for a Facility at Andrews County, Texas ML19105B2172019-04-19019 April 2019 Memorandum to C. Regan Summary of March 20, 2019, Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the Interim Storage Partners Consolidated Isf Application (W/Enclosures 1 and 2) ML19072A1562019-03-14014 March 2019 Summary of Partially Closed Public Meeting to Discuss Request for Additional Information Issued in Connection with Nrc'S Review of the ISP Cisf Application for a Facility at Andrew'S County, Tx (W/Encl. 1&2) ML19032A2302019-02-0404 February 2019 Summary of Closed Public Meeting to Discuss RAI Issued in Connection with Nrc'S Review of the Interim Storage Partner Consolidated Isfs Application for a Facility at Andrews County, Texas (W/Encl. 1&2) ML18267A2112018-09-25025 September 2018 Memorandum to A. Rivera-Varona Summary of August 29, 2018, Public Meeting with Interim Storage Partners to Discuss Consolidated Emergency Response Plan for Its Proposed WCS Consolidated Interim Storage Facility (W/Enclosure 1 and 2) 2019-05-06
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 14, 2019 MEMORANDUM TO: Christopher M. Regan, Deputy Director Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards FROM: John-Chau Nguyen, Senior Project Manager /RA/
Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards
SUBJECT:
SUMMARY
OF FEBRUARY 19, 2019, PARTIALLY CLOSED PUBLIC MEETING TO DISCUSS REQUEST FOR ADDITIONAL INFORMATION ISSUED IN CONNECTION WITH NRCS REVIEW OF THE INTERIM STORAGE PARTNERS CONSOLIDATED INTERIM STORAGE FACILITY APPLICATION FOR A FACILITY AT ANDREWS COUNTY, TEXAS PURPOSE:
For the U.S. Nuclear Regulatory Commission (NRC) staff and representatives from Interim Storage Partners (ISP) to discuss NRCs request for additional information (RAI) dated November 16, 2018 (Agencywide Documents Access and Management System (ADAMS)
Accession No. ML18320A184), issued in connection with its review of the license application for the proposed ISP Consolidated Interim Storage Facility (CISF). The meeting was noticed on February 7, 2019 (ADAMS Accession No. ML19038A440).
MEETING
SUMMARY
On February 19, 2019, NRC staff held a partially closed Category 1 public meeting with representatives from ISP at the NRCs headquarters in Rockville, Maryland. Attendees included ISP and its contractors, NRC staff, and members of the public. The discussion followed the agenda provided in Enclosure 1. NRC and ISP staff and contractors discussed the RAIs throughout the meeting. Members of the public were given an opportunity to ask questions pertaining to the RAIs following the open discussions between NRC and ISP during the second portion of the meeting. The list of meeting attendees is provided in . ISP provided presentation slides prior to the meeting that can be found in ADAMS at Accession No. ML19050A019.
CONTACT: John-Chau Nguyen, NMSS/DSFM (301) 415-0262
C. Regan The first portion of the two-part meeting was closed to the public and allowed NRC and ISP participants to discuss proprietary issues associated with four RAIs. Following introductions and opening remarks, representatives from ISP made a presentation on the four RAIs, which addressed regional geology and geotechnical issues, stratigraphy and associated material properties at the site, seismic hazard evaluation, and settlement properties at the site.
After completion of the closed portion of the meeting, meeting participants transitioned to the open portion of the meeting, which began at 3:00 p.m. Following introductions and opening remarks, ISP made a short presentation, revisiting RAIs that were previously discussed at the January 10, 2019, public meeting between NRC and ISP. A summary of that meeting can be found in ADAMS at Accession No. ML19032AA230.
ISP further discussed its planned approach to responding to RAIs 15-2, 15-3, 15-4, and 15-9, which seek information about the safety classification of the MP-187 cask system structures, systems, components, drawings and additional information for greater-than-Class C (GTCC) canisters and other GTCC storage system information. ISP also further discussed its approach to responding to RAI 15-13, addressing aging management program considerations for proposed GTCC waste storage systems at the site.
NRC and ISP addressed the criteria required for adequate responses to the RAIs. Staff and ISP discussed applicable criteria required by NRC requirements in 10 CFR Part 72, and guidance provided in Interim Staff Guidance 17, Spent Fuel Project Office, Interim Storage of Greater Than Class C Waste. ISP indicated that it seeks to ensure that its application, and responses to RAIs, will address all relevant NRC regulations, will consider information presented in NRC guidance, and will be informed by, and consistent with, prior NRC licensing decisions related to GTCC waste canisters.
After the business portion of the open meeting, members of the public participating by phone were given the opportunity to ask questions and make comments to NRC staff. The public inquired about ISPs responses to RAIs and when they would be made publicly available; NRC staff indicated that the applicant is still working on its responses to the current set of RAIs and that NRC is awaiting final responses. Staff also indicated that it will continue to seek to make available presentation slides and other information, for future meetings, as soon as practicable prior to such meetings.
No regulatory decisions were made at the meeting.
Docket No.: 72-1050 CAC/EPID No. 001028/L-2017-NEW-0002
Enclosures:
- 1. Meeting Agenda
- 2. Attendance list
C. Regan
SUBJECT:
SUMMARY
OF FEBRUARY 19, 2019, PARTIALLY CLOSED PUBLIC MEETING TO DISCUSS REQUEST FOR ADDITIONAL INFORMATION ISSUED IN CONNECTION WITH NRCS REVIEW OF THE INTERIM STORAGE PARTNERS CONSOLIDATED INTERIM STORAGE FACILITY APPLICATION FOR A FACILITY AT ANDREWS COUNTY, TEXAS, DOCUMENT DATE: March 14, 2019 DISTRIBUTION:
DSFM r/f NRC Attendees Filename: G:\SFST\Nguyen\Casework\WCS\02192019 Partially Closed Meeting to discuss RAIs/RHT MTNG
SUMMARY
02192019.docx ADAMS Package No.: ML19072A161 Memo: ML19072A156 Slides: ML19050A019 OFFICE: NMSS/DSFM/SFLB NMSS/DSFM/SFLB NMSS/DSFM/SFLB NMSS/DSFM/SFLB NAME: RTurtil JNguyen WWheatley IBerrios DATE: 3/ 11 /2019 3/ 13 /2019 3/ 12 /2019 3/14/2019 OFFICIAL RECORD COPY
AGENDA Partially Closed Meeting between Interim Storage Partners, LLC (ISP),
and the Nuclear Regulatory Commission (NRC)
February 19, 2019 1:00 p.m. - 4:00 p.m. (Eastern Standard Time)
Room: 3WFN-1C03
Purpose:
Partially Closed Meeting to discuss NRCs request for additional information, dated November 16, 2018, issued in connection with NRCs review of the license application for the proposed ISP Consolidated Interim Storage Facility at Andrews County, TX.
Closed Meeting 1:00 p.m. - 1:05 p.m. Introductions / Opening Remarks NRC/ISP 1:05 p.m. - 2:00 p.m. Discussion of request for additional information ISP/NRC (RAIs) P-2.6-1, P.2.6-3 and P-2.6-5.
2:00 p.m. - 2:45 p.m. Discussion of RAIs P-2.6-4 and P-2.6-6 ISP/NRC 2:45 p.m. - 3:00 p.m. Adjourn/Transition to Open Meeting Open Meeting 3:00 p.m. - 3:10 p.m. Introductions / Opening Remarks NRC/ISP 3:10 p.m. - 3:45 p.m. Discussion of RAIs relating to Greater Than ISP/NRC Class C canisters and Aging Management Programs 3:45 p.m. - 4:00 p.m. Opportunity for Public Questions and NRC/Public Comments for NRC staff 4:00 p.m. Adjourn Enclosure 1
MEETING ATTENDEES
Participants:
ISP and the Nuclear Regulatory Commission Date: February 19 2019, 1:00 P.M. - 4:00 P.M.
Location: Three White Flint North, Room 1C03 NAME AFFILIATION John McKirgan NRC John-Chau Nguyen NRC Zuhan Xi NRC Luissette Candelario NRC Darrell Dunn NRC Jin-Ping Gwo NRC Richard Turtil NRC Gordon Bjorkman NRC Gerry Stirewalt NRC Jenise Thompson NRC David Heeszel NRC Angel Moreno NRC Enclosure 2
NAME AFFILIATION Jeff Isakson ISP Elicia Sanchez ISP Jack Boshoven ISP Mike Callahan Governmental Strategies Earl Easton Independent Contractor Renee Murdock ISP Ben Mason ISP Jenny Caldwell ISP Stephen Burdick Morgan Lewis Derek Kilday Geo Services Veena Gubbi/call in New Jersey State Government Michael Keegan/call in Public/Dont Waste Michigan Nuclear Information and Resource Diane DArrigo/call in Service Donna Gilmore/call in public Kristopher Cummings/call in Scientech (NETCo)
Laura Schwartz/call in Intl. Technology and Trade Association AHoffman/call in Public