IE Insp Rept 50-206/80-20 on 800616-19.No Noncompliance Noted.Major Areas Inspected:Major Maint,Major Surveillance, IE Bulletin & Circular Followup & Independent Insp Effort
ML13323A810
Person / Time
Site: San Onofre 
Issue date: 07/09/1980
From: Faulkenberry B, Horn A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML13323A809 List:
References
50-206-80-20, NUDOCS 8007300343
Download: ML13323A810 (3)


Text

U. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

REGION V

Report N /80-20 Docket N License N DPR-13 Safeguards Group Licensee:

Southern California Edison Company 2244 Walnut Grove Avenue Rosemead, California 91770 Facility Name:

San Onofre Unit 1 Inspection at:

San Onofre Inspection conducted:

June 16-19, 1980 Inspectors:

71, 7g o A. (.Horn, Reactor inspector bate Signed Date Signed Date Signed Approved By:_

7Z

><liu,/o B. H. Faulkenberry, e,.actor Projects Section 2 Date Signed Reactor Operations d Nuclear Support Branch Summary:

Inspection on June 16-19, 1980 (Report No. 50-206/80-20)

Areas Inspected: Routine, unannounced inspection of major maintenance, major surveillance, IE Bulletin and Circular followup, and independent inspection effort. This inspection involved 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by one NRC inspecto Results:

No items of noncompliance were identifie RV Form 219 (2)

SO7 Soo 2tJ,

DETAILS 1. Persons Contacted

  • R. Brunet, Superintendent, Unit 1
  • J. Dunn, PQAS
  • G. McDonald, QA/QC Supervisor
  • M. Wharton, Supervising Engineer H. Bentz, Watch Engineer H. Timmons, QA Engineer B. Jones, Maintenance Foreman
  • Denotes those persons who attended the exit interview. Also present at the exit interview were the NRC resident inspectors, R. Pate and L. Mille. Surveillance (Major)

The inspector reviewed the periodic testing of the diesel generators required by Technical Specification 4.4B. The following operating instructions were reviewe S-2-11 Diesel Generator Operation and Monthly Testin S-2-12 Diesel Generator Testing at Refueling Interval S-3-Cold Operation Test of the Safety Injection Syste QC Inspection Procedure S-XII-QC for Diesel Generator Inspections and Maintenanc No items of noncompliance or deviations were identifie. Maintenance (Major)

The records and procedures of several major maintenance activities scheduled during the refueling outage were reviewed. These included QC inspection procedures:

S-XII-Inspection and Repair of Main Feed Pump S-XII-1.10 Inspection and Repair of Charging Pump S-XII-1.12 Inspection and Repair of Salt Water Cooling System Pump S-XII-1.13 Inspection and Cleaning of Component Cooling Heat Exchanger Also reviewed were:

Engineering Procedure S-V-2.14 Inservice Testing of Pump *

-2 Maintenance Procedure S-I-1.14 General Maintenance Procedur No items of noncompliance or deviations were identifie. IE Bulletin/Circular Followup a. (Closed) Bulletin 80-05 The inspector reviewed the licensee's response to the bulletin and determined that design conditions exist to prevent vacuum damage to tanks. Two tanks, the radioactive chemical drain tank and the decontamination drain tank, have valves in their vent lines administratively controlled.LOCKED OPEN. In addition to the LOCKED OPEN vent line valves, these tanks are protected by other lines connected to them that could prevent vacuum conditions from causing damage in case the LOCKED OPEN vent valves were close b. (Closed) Bulletin 80-09 The licensee has determined that this bulletin is not.applicable to San Onofre Unit c. (Open) Bulletin 80-12 The licensee addressed all concerns of the bulletin in their response. The item remains open pending verification of changes to procedures as committed to in their respons. Followup on Previously Identified Item (Open) (Item 79-17-06) - Commitment by licensee to clarify inoperable rod definition and criteria for shutdown applicable to Technical Specification 3.5. The inspector reviewed the revised Operating Instruction S-3-5.12

"Control Rod System Malfunctions", Revision 10. The procedure clearly defines inoperable rod, but there are conflicting requirements in two sections as to when to shutdown with inoperable rods. The licensee agreed to clarify the two section. Exit Interview The inspector met with the licensee representatives denoted in paragraph 1 on June 19, 1980 to discuss the findings of this inspectio I