IR 015000046/1980098
| ML13323A936 | |
| Person / Time | |
|---|---|
| Site: | San Onofre, 015000046, 02700048 |
| Issue date: | 01/20/1981 |
| From: | Book H, Thomas R, Zurakowski P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | SOUTHERN CALIFORNIA EDISON CO. |
| Shared Package | |
| ML13323A935 | List: |
| References | |
| 15000046-80-98, NUDOCS 8103250144 | |
| Download: ML13323A936 (5) | |
Text
II Report N Docket N us
_
Safeguards Grou_
Licensee:
Facility Name:
Nuclear Engineering Company Inspeczion at:
Richland, Washington Inspection conzuctea:
December 15, 1980 Inspectors:
,Ct P; R. Zurakowski, Radiation Specialist n
Approved by:
R. D. Thomas, Chief cte Yigne Materials Radiological Protection Section a a S igned dpproved y:
j IZ
___2-_
_
1/0 H. E. Book, Chief Date Signed Fuel Facility and Materials Safety Branch Su ary:
Inspection on December 15, 1980 (Report No. 15000046/80-98)
As part of the low level waste inspection conducted during December 15-18, 1980 trailer number 7433006 and associated shipping records were inspected on December 15, 1980 and are detailed in this report. No packages were opene A representative from the Department of Transportation was not present during this inspection. James A. Ferguson from the State of Washington, Department of Social and Health Services was present during this inspectio Results: One apparent item of noncompliance with NRC/DOT regulations was observe See paragraph 3 of the enclosed report. It appears that the NRC Region V office, the State of Washington and Department of Transportation are the appropriate organizations to take enforcement action RV Form 219 (2)
810 32 0 q/
DETAILS Persons Contacted Vern Apple, Site Manager, NECO Robert Phalen, Assistant Site Manager, NECO Floyd Dickson, Radiation Control and Safety Officer, NECO Rebecca Cropper, Radiation Technician, NECO Rob Rittenberg, Radiation Technician, NECO James A. Ferguson, State of Washington, Department of Social & Health Services Backaround As part of a low level waste inspection conducted during December 15-18, 1980 at Richland. Washington, trailer number 7433006 and associated shipping papers were inspected on December 15, 1980 and are detailed in this report. Radiation surveys were performed with a Xetex model 305B, serial number 8421, due for recalibration February 10, 1981. Contamination surveys of unloaded trailers and checks for removable radioactive contamination were performed with an Eberline E-520 and HP-260 pancake probe, serial number 7907, due for recalibration February 12, 198 Insoection Licensee - Shipper:
San Onofre Nuclear Generating Station, Unit 1 DN 5000206 Southern California Edison Company Rosemead, California Broker:
Southwest Nuclear Company Pleasanton, California Shipment Inspacted:
December I, 1980 Carrier:
Home Transportation Incorporated Trailer:
7433006 Freight Bill:
Shippers No. 80-77 This trailer transported 168 drums of LSA radioactive waste, a partial description of which is provided as Attachment A. This was an exclusive use shipmen. Radiation surveys of the trailer indicated a maximum dose rate of 4 mr/hr at the surface of the trailer and 5.8 mr/hr at two meters from the sides of the trailer. The dose rate in the cab was measured to be 0.3 mr/h. Title 49, Part 173.392(c)(1) requires LSA wastes to be packaged in strong tight packages so that there will be no leakage of radioactive materials under conditions normally incident to transportation. Contrary to the above, during the unloading of trailer 7433006 drum number F-55 (0776)
was observed to have a loose lock ring because the attached welded bolt had broken loos. Checks of the drums for removable radioactive contamination, and a survey of the truck bed after unloadina indicated no sionificant radioactive contamination above backgroun *
OE LIVIRYRE[CE IPT - Consignee Copy
-
rt N
ShIpper's Number IDale/0
CONSIGNED TO
--
fcn Subject to Section 7 of con ditions of applicable bill of lad A_
In 9,
if this shipment is to be
'A. T S'E.
COUNTY delivered.
the consignee with-.
I out recourse on the consigno /:
.the consignor shall sign the following statement:
The carrier shall not make delivery of this shipment with
-
r I
out payment of freight and all Kind of Package, Description of Articles, Special Marks, and Exceptions t-H <tion)
o aste CoL Numbager WEIGHT to C _other lawful charge S n a e o(e C n-,,9-o~r_
UN LESSA GREATERVALUE ISDECL.ARED,SHIPPER T
istocetifythattheabrenammate
____________________________________________________T_____
Ifcharges are to be pead are Droper y c~a~s~le~
o, rf-6161,7 e0'ite or stamp her T be HEREBY RELEASES THE VALUE TO $5,000 PER 2 e and labeed, and rein propq conde oepaid."
TON OF 2,000 POUNDS FOR EACH ARTICL fort ansporation accord t Uteas1 c ec ul n, fc th'ie p Part me it of Tra n
)r!at io iReceived S
/.to apply in prepayment of the I__\\__'_.charges on the property de scribed hereo T,
~Agent or Cashier
-~
- '~7-~
~
-.
r Per_
_____
r r
7 7 1 j rPe(The signature here acknow ledges only the amount prepaid.)
/
7-
.
i, Charges Advanced:
7A LENGTH WIDTH HEIGHT rra W-7'
.
.
.
.
Iecp sohrien T
SHIPPER SIGN HERE Received the property described above in good condition,.
The agreed or declared value of the property is hereby specifically stated by the shipper to be not exceeding per Carrier Home Transportation Co., In ompanW rI.(.y0
_
_
_
_
Driver B y Date and Time
/
DELIVERY RECEIPT d
roperty desc d
ov in good conditio Consignee Company Name B y Z
d~
Th/A Title Date Time PICK-UP
,'
__
SCHEDULED ARRIVAL SH WPPER NOTIFIEDOF ARR_
LOADING BEGAN LOADING COMPLETED UNIT RELEASED Date Time Date Time Date Time Date Time Date Time!
7f Shipper Co. Name c,
/r
,
By
-
Title DELIVERY DULED ARRIVAL CSElG E NOTIFIEDof AR UNLOADING BEGAN UNLOADING COMPLEI ED UNIT RELEASED Time Date Tirn I Date
/
Time Dalt Time Date T ire Consignee Co. Name
By-L
'7 Title P23 Co gnee Cop
- 3 W-24
~~3-Consignee COPY 7 3
.AUIUIAG i vI-WASIE Shq,-Nf Et DISPOSAL FORM
ommere Ci. PleasantonCA_ 9 UCLEAR ENGIN GO COMPANY, IN Realty NV 89003 o 4-37 EXECUTIVE (502) 426-7160
P.O. BOX 7246 LOUISVILLE, KENTUCKY 40207 C1 P.O. Box 638 TOFNS P7Ofe(154 Richland, WA 99352 DATE
/
/
,.
,.,~
Illinois Office: (815) 454-2624 (0)3721 DT F
HI P~ir Calitorn~a Office: (415) 932-4800 CARRIER:
NO. 21709 PAGE OF 4PE 4179 C R 1 2 1 1 N P U D TOTAL QUANTITY PROPER SHIPPING NAME E HAZARD CLASS TOTAL WEIGHT (PER 49 CFR 172.101)INPU D
Radioactive Device, N. adioactive Material Radioactive Material, Fissile, N. Radioactive Material
/
A Radioactive Material, Low Specific Activity, N.O Radioactive Material L
_
_
_
_
_
_
I Radioactive Material, N. Radioactive Material
__ Radioactive Material, Limited Quantity, NOS
-
Radioactive Material Radioactive Material, Special Form, N.O Radioactive Material ()
(2)
(3)
(4)
(5)
16)
(7)
.(8)
(9)
(10)
(12)
(13)
(14)
115)
Speei)l Radiation Levels Ite Cuic Weiht hyica Chmial NIciZuar-Source
- Activil..........MR/HR
.
.
.
.
.
.
.
.
.
.Type
Cubc o
s Chenicalteril Material ci Cures Transport Transport
.
Fissile of 0 Feet 1Powrds(
Form Form Radionuclide lGrarrie (Kilograms)
(Q Millicardes Surface 3 Feet Group Inde Label Class Container
_Radioactive Radioactive Radioactive Radioactive Radioactive Radioactive R:d cacive-Radioactive
Radioactive
-
Radioactive
..
(,
Radioactive Radioactive
.
-Radioactive Radioactive >--L4,.--
__________Radioactive THE OTALS
'
--
tp af
..
,'.
.
(.i
,
,ItS tS TO CERTIFY THAT TEABOVE-NAMED MATERIALS ARE PROPERLY CLASSIFIED, DESCRIBED, PACKAGED, ISTA ATCE.AEIiOPINEWT L'EUAIN PLCBEA1TV IrKEID AND LABELED AND ARE IN PROPER CONDITION FOR TRANSPORTATION ACCORDING TO APPLICABLE
- .*-'THSITOCRFYHAATCLSRENCMPACEWHALRGLTOSAPIABETTE LEGILATIONS OF THE DEPARTMENT OF TRANSPORTATION.:.---,-.
~
Authorizd Sirnst*
_7 7777--77 CAR'RIER'S.'COPY -_.<.-..