Informs That post-accident Sampling Sys Presently in Startup Phase Will Be Operational Prior to Return to Power from Outage.Documentation for post-implementation Sys Will Be Provided by 821201
ML13317A391
Person / Time
Site: San Onofre Southern California Edison icon.png
Issue date: 11/02/1982
From: Krieger R
SOUTHERN CALIFORNIA EDISON CO.
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.B.3, TASK-TM TAC-44128, NUDOCS 8211040428
Download: ML13317A391 (1)


Text

Southern California Edison Company P. 0. BOX 800 2244 WALNUT GROVE AVENUE ROSEMEAD. CALIFORNIA 91770 November 2, 1982 Director, Office of Nuclear Reactor Regulation Attention: D. M. Crutchfield, Chief Operating Reactors Branch No. 5 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Gentlemen:

Subject:

Docket No. 50-206 NUREG-0737, Item II.8.3 - Post-Accident Sampling Capability San Onofre Nuclear Generating Station Unit 1

Reference:

Letter, K. P. Baskin, SCE, to D. M. Crutchfield, NRC, NUREG-0737, Item II.B.3 - Post-Accident Sampling Capability, August 12, 1982 The referenced letter informed you that we would be able to supply you with the information necessary for your post-implementation review by November 1, 1982. Subsequently you provided us with additional clarification by letter dated October 7, 1982.

This clarification of your needs for post-implementation review, when compared to what we had prepared up to that point indicated that our response would not be sufficient.

Thus, the purpose of this correspondence is to inform you that we will be able to provide you with the documentation for your post-implementation review by December 1, 1982. The post-accident sampling system is presently in the startup phase and will be operational prior to return to power from this outage.

If you have any questions regarding the above discussed information, please let me know.

Very truly yours, R. W. Krieger Supervising Engineer San Onofre Unit 1 Licensing 821104042B 821102 PDR ADOCK 05000206 P