ML20236F861

From kanterella
Revision as of 03:56, 22 February 2021 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Safety Insp Repts 50-295/87-32 & 50-304/87-33 on 870921-1026.Util Will Be Notified by Separate Correspondence of NRC Decision Re Enforcement Action
ML20236F861
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 10/29/1987
From: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Reed C
COMMONWEALTH EDISON CO.
Shared Package
ML20236F862 List:
References
EA-87-211, NUDOCS 8711020322
Download: ML20236F861 (2)


See also: IR 05000295/1987032

Text

p;A,Q *

,

O

'

Wy(<

'

k[; , l b e*

w" , : g f+

s ,

,

007 2 91gj7 ;

- Dbi:ket No,' 50-295 - ,

" '

! Docket No. 50-304

EA'87-211

'

Commonwealth' Edison: Company.

. ATTN: Mr. ' Cordell Reed .~

Vice President'

4 Post Office Box:767

'

Chicago,, IL 60690

Gentlemen:

This' refers to.the special safety inspection conducted by NRC inspectors

,

,' M. M. Holzmer.and P. L.. Eng of this' office on September 21 through October 26,

1987, ofLactivities at the Zion Nuclear Generating Station, authorized by

Licenses No. DPR-39 and No. DPR-48,.

The inspection focused on the testing and operability of. pressure isolation

check valves (PIVs) between the reactor coolant system (RCS) and the low

pressure emergency core cooling systems (ECCS) to which the RCS.is connected.

~

LThe enclosed copy of our inspection' report identifies specific areas examined

during the inspection. Within these areas, the inspection consisted of a

-selective examinationtof. procedures and representative records, observations,

and interviews with personnel.

a :We. are releasing this report at this' time for your information. You will

be notified by separate correspondence of our. decision regarding enforcement-

action based on.the. findings of this inspection. No written response is

required until you'are-notified of any proposed enforcement action.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this. letter .and the enclosure, will be placed in the NRC Public Document

Room.

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

g1020M [ 295 Om SIGNE N C. 3. Itcmgr.nJg .

G Charles E. Norelius, Didctor

Division of Reactor Projects

'

Enclosure: . Inspection Reports

No. 50-295/87032(DRP.); and

'No. 50-304/87033(DRP)

Attachment: Zion Emergency Core

.

' Cooling System Simplified Diagram

.See Attached Distribution

Y

RIII RIII RIII RIII RIII MQ

'9AJ. to k W&f% p c

VanSickle/ims inds Forney Grome Not ,e bs g \

, Join ls? p enNl *(g so uS7 p d If1 L

,

_ _ _ _ . _ _ _ _ _ . _ _ _ _ . _ _ . _ _ - _ _ _ _ _ - _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _

' '

I

. _ , _- - .. -

y y. ,. m

, ,

,

, ,

$ ' - \

r '

s ; m.

,

,

'

'

!CommonWealthEEisonCompany.

'

-

.

,

2; 2l 1997)

..,

1 Distribution- -

p i;p .

<

cc W/ enclosures: . .

. ..

' T. J.(Maiman,OVice President,

'PWRtOperations- .

.

=0. Butterfield,. Nuclear.

>

Licensing Manager', .

G..J.-'P11m1,: Station' Manager >

--

' Jan Norris', : Project. Manager, NRR

-

'-

DCD/DCB (RIOS).

'Li_ censing Fee Management Branch

x LResident Inspector, RIIIl

5

'

1 Richard Hubbard-

, : J. W. : McCaffrey', ~ Chief, Public

. Utilities Division

Mayor;iCity;of Zion

.J;-Lieberman,:OE-

o lJ. Goldberg, OGC,

.F. Miraglia,':NRR

, ,

a

a

i

u

1

l

1

l l

. .,

,

._.__.__._m.__ ___.__________.__t. ___a