p;A,Q

'

l b e*

O

,

Wy(<

k[;

,

w" , : g f+

007 2 91gj7 ;

'

s

,

,

' ' '

Dbi:ket No,' 50-295 -

-

,

" '

! Docket No. 50-304

EA'87-211

Commonwealth' Edison: Company.

. ATTN:

Mr. ' Cordell Reed .~

'

Vice President'

Post Office Box:767

4

'

Chicago,, IL 60690

Gentlemen:

This' refers to.the special safety inspection conducted by NRC inspectors

M. M. Holzmer.and P. L.. Eng of this' office on September 21 through October 26,

,

,'

1987, ofLactivities at the Zion Nuclear Generating Station, authorized by

Licenses No. DPR-39 and No. DPR-48,.

The inspection focused on the testing and operability of. pressure isolation

check valves (PIVs) between the reactor coolant system (RCS) and the low

pressure emergency core cooling systems (ECCS) to which the RCS.is connected.

~

LThe enclosed copy of our inspection' report identifies specific areas examined

during the inspection. Within these areas, the inspection consisted of a

-selective examinationtof. procedures and representative records, observations,

and interviews with personnel.

We. are releasing this report at this' time for your information.

You will

a

be notified by separate correspondence of our. decision regarding enforcement-

action based on.the. findings of this inspection.

No written response is

required until you'are-notified of any proposed enforcement action.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this. letter .and the enclosure, will be placed in the NRC Public Document

Room.

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

Om SIGNE N C. 3. Itcmgr.nJg

g1020M [

295

.

G

Charles E. Norelius, Didctor

Division of Reactor Projects

'

Enclosure: . Inspection Reports

No. 50-295/87032(DRP.); and

'No. 50-304/87033(DRP)

Attachment:

Zion Emergency Core

.

' Cooling System Simplified Diagram

.See Attached Distribution

Y

Q

RIII

RIII

RIII

RIII

RIII

M

'9AJ.

to k

W&f%

p c

VanSickle/ims

inds

Forney

Grome

Not ,e bs

g \\

Join ls?

p enNl

  • (g

so uS7

p d If1

L

,

,

_ _ _ _ . _ _ _ _ _

. _ _ _ _ . _ _ . _ _ - _ _ _ _ _ - _ _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _

' ' '

I

'

. _ ,

_-

-

..

-

,

,

,

,

y

y.

,. m

,

$

' -

\\

s ; m.

'

r

,

,

-

!CommonWealthEEisonCompany.

2;

2l 1997)

'

'

'

.

,

. . ,

1 Distribution-

-

p i;p .

cc W/ enclosures: .

.

. ..

<

' T. J.(Maiman,OVice President,

'PWRtOperations- .

.

=0. Butterfield,. Nuclear.

Licensing Manager', .

>

G..J.-'P11m1,: Station' Manager >

--

' Jan Norris', : Project. Manager, NRR

-

DCD/DCB (RIOS).

'Li_ censing Fee Management Branch

'-

x

LResident Inspector, RIIIl

1 Richard Hubbard-

'

5

, : J. W. : McCaffrey', ~ Chief, Public

. Utilities Division

Mayor;iCity;of Zion

.J;-Lieberman,:OE-

lJ. Goldberg, OGC,

o

.F. Miraglia,':NRR

,

,

a

a

i

u

1

l

1

l l

.

.,

,

._.__.__._m.__

___.__________.__t.

___a