ML20246P400
| ML20246P400 | |
| Person / Time | |
|---|---|
| Site: | 05000000, 05000603, 05000604 |
| Issue date: | 03/23/1989 |
| From: | Rouse L NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Jazel Parks ENERGY, DEPT. OF |
| Shared Package | |
| ML20246P404 | List: |
| References | |
| NUDOCS 8903280214 | |
| Download: ML20246P400 (1) | |
Text
-........
Docket Nos. 50-603 50-604 Mr. Joe W. Parks Deputy' Assistant Manager MAR 2 31989 for Enriching Operations U.S. Department of Energy l
Oak Ridge Operations j
P.O. Box 2001 Oak Ridge, TN 37831-8650
Dear Mr. Parks:
Thank you for your informative response of February 15,.1989.to our letter of February 1,1989 concerning assurance by All Chemical Isotope Er.richment, Inc.
(A1ChemIE) of adequate decommissioning fonding under 10 CFR 550.33(k) and 550.75.
In examining our liransing review for A1ChemIE, we have concluded that'the decommissioning funding requirements of 10 CFR 650.33(k) and 950.75, which are designed to protect the public health and safety, are not applicable in this instance, where the issue is the protection of the common defense and security.
From this conclusion, we have accepted the financial assurances for protection of the common defense and security already provided'by AlchemIE.
Enclosed is a copy of the letter we have sent A1ChemIE confirming 'this.
The next milestone for AlChemIE to achieve toward issuance by NRC of an Operating License for AlChemIE Facility.1 CPDF will be NRC's determination, as specified by Condition III.9 of Construction Permit No. CPEP-1,-that A1ChemIE has established adequate arrangements for security at the CPDF., As we have 1
l previously discussed, until the NRC has made this determination, any' activities
-l i
by A1ChemIE involving access to the classified machines and information j
(including those covered by Condition III.6 of CPEP-1) must be under DOE.
security oversight.
We hope you find this information useful.
If you have any q'uestions on this l
matter, please contact me, FTS 492-3328.
Sincerely, omrm,m
%v l
Leland C. Rouse, Chief Fuel I ycle' Safety Branch Division of Industrial and l
Medical Nuclear Safety Office of Nuclear Material Safety and Safegurds
Enclosure:
As stated DISTRIBUTION:
' Docket:Nosr5046F& 50!60CEPDRENRC7Fils7Clii6tsIM IMAF R/F IMSB R/F I
NMSS R/F IMNS Central R/F JJSwift " FLBrown LCRouse BBordenick WCline, Reg II 4Mid 4/rq 0
3 m m..s A
W e ~ c 4 L o K d, cvve64 0FC : iF
/
- IMIF
- IMIF NAME: / swift:lg rown
- L Rouse
...__m.__________.______
- 02 # 3/89
- 847/89 DATE:
02/6 /89
'-------------------------------------------pO9-8903280214 990323 PDR ADOCK 06000603 0FFICIAL RECORD COPY I k I
pgsc
_