Forwards Safety Evaluation Supporting Util 831105,880822 & 1031 Responses to Generic Ltr 83-28,Items 3.1.3 & 3.2.3 Re Tech Specs for post-maint Testing Requirments
ML20196B801
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 12/02/1988
From: Muller D
Office of Nuclear Reactor Regulation
To: Bliss H
COMMONWEALTH EDISON CO.
Shared Package
ML20196B806 List:
References
GL-83-28, TAC-53057, TAC-53058, TAC-53897, TAC-53898, NUDOCS 8812070035
Download: ML20196B801 (3)


Text

. .

3 ,

December 2, 1988 Docket'Nos. 50-295 DISTRIBUTION and 50-304- 1Dockettf.11e J JNorris NRC & Local PDR, OGC PDIII-2 r/f EJordan Mr. Henry E. Bliss DMuller BGrimes Director of Nuclear Licensing MVirgilio ACRS(10)

Comonwealth Edison Company LLuther PDIII-2 p/f t

Post Office Box 767 GHolahan Chicago, Illinois 60690

Dear Mr. Bliss:

RE: GENERIC LETTER 83-28 ITEMS 3.1.3 AND 3.2.3 (POST-MAINTENANCE TESTING) FOR ZION NUCLEAR POWER STATION (ZION STATION) (TAC NOS. 53057, 53058, 53897 AND 53898)

The Generic Letter 83-28 Items 3.1.3 and 3.2.3 required Zion Station to review its Technical Specifications for post-maintenance testing requirements that ma.' degrade rather than enhance safety. You have responded to these requireme,'ts by submittals dated November 5, 1983, August 22, 1988 and a verbal comitment during a telephone conference on October 31, 1988. We have reviewed the above mentioned information and conclude that the responses for Generic 4

Letter 83-28 Items 3. 2 and 3.E.3 are acceptable. The enclosed Safety Evaluation gives details of our review. Based on the.t. we consider the action on these items closed.

Sincerely, f

(.

Danici R. Muller, Director c Project Directorate III-2 Division of Reactor Projects - III, IV, Y and Special Projects ec: See next page PDI 2M ,P011 , LA :PD JNorri ymj 'LLutheH P

Du bi 12/,2' /88 G812070035 8G1202 12/,7 /88 o

12/L /88 h PDR ADOCK 05000293 P PDC

e .

e

  1. o, UNITE D STATES 8 }, NUCLEAR REGULATORY COMMISSION

g / December 2, 1988 Docket Nos. 50-295 and 50-304 Mr. Henry E. Bliss Director of Nuclear Licensing Commonwealth Edison Company Post Office Bex 767 Chicago, Illinois 60690

Dear Mr. Bliss:

RE: GEllERIC LETTER 83-28 ITEMS 3.1.3 AND 3.2.3 (POST-MAINTENANCE TESTING) FOR ZION NUCLEAR POWER STATION (ZION STATION) (TAC NOS. 53057, 53058, 53897 AND 53898)

The Generic Letter 83-28 Items 3.1.3 and 3.2.3 required Zion Station to review its Technical Specifications for post-maintenance testing requirement: -

thht may degrade rather than enhance safety. You have responded to these requirements by submittals dated November 5,1983, August 22, 1988 and a verbal commitment during a telephone conference on October 31, 1988. We have reviewed the above u ntioned information and conclude that the responses for Generic .

Letter 83-2f. Items 3.1.2 and 3.2.3 are acceptable. The enclosed Safety Evaluation gives details of our review. Based on that, we consider the acti m on these items closed.

Sincerely, Daniel R. Muller, Director Project Directorate III-2 Division of Reactor Projects - III, IV, Y and Special Projects cc: See next page i

Mr. Henry E. Bliss Connonwealth Edison Company Zion Station cc:

Robert J. Vollen Esquire Mr. Michael C. Parker, Chief 109 North Dearborn Street Division of Engineering Chicago, Illinois 60602 Illinois Department of Nuclear Safety Dr. Cecil Lue-Hing 1035 Outer Park Drive, 5th Floor Director of Research and Development Springfield, Illinois 62704 Metropolitan Sanitary District of Greater Chicago 100 East Erie Street Chicago, Illinois 60611 Phillip Steptoe, Esq.

. Sidley and Austin One First National Plaza Chicago, Illinois 60603 Mayor of Zion Zion, Illinois 60099 I!11nois Department of Nuclear Safety ATTN: Manager, Nuclear Facility Safety 1035 Outer Park Drive, 5th Floor Springfield, Illinois 62704 U.S. Nuclear Regulatory Commission '

Resident Inspectors Office 105 Shiloh Blvd.

Zion. Illinois 60099 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 199 Roosevelt Road, Bldg. #4 Glen Ellyn, Illinois 60137

. . . . . _ - _ _ _ . - _ _ _ - -