Forwards Request for Addl Info Re Proposed Record Storage Ctr,Including Design Details Concerning Location & Spacing of Fire Smoke Detectors.Response Requested within 45 Days of Ltr Date
ML20206M116
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 08/14/1986
From: Hinson C
Office of Nuclear Reactor Regulation
To: Robert Williams
PUBLIC SERVICE CO. OF COLORADO
References
TAC-61578, NUDOCS 8608200468
Download: ML20206M116 (5)


Text

l

g. j#"" '%
e

/ 'n UNITED STATES NUCLEAR REGULATORY COMMISSION

{* .. j WASHING TON, D. C. 20555

) i

...../ August 14, 1986 i l

Docket No. 50-267 .

Mr. R. O. Williams, Jr.

Vice President, Nuclear Operations Public Service Company of Colorado Post Office Box 840 Denver, Colorado 80201-0840

Dear Mr. Williams:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - PROPOSED RECORD STORAGE CENTER AT FORT ST. VRAIN (FSV)

Reference:

D. Warembourg (PSC) letter to H. Berkow (NRC), Record Storage Center at FSV, April 25,1986(P-86069)

In the reference letter, you described your plans to construct a new Record Storage Center at FSV. This structure will be separate from the existing record storage building. You also submitted a copy of the applicable codes and standards that will provide the design basis for the new Record Storage Center, as well as a listing of ten exceptions you requested to these codes and standards.

NRC guidance for the design of facilities for the storage of records is con-tained in Standard Review Plan (SRP) Section 17.1.17.4. SRP Section 17.1.17.4 references Regulatory Guide 1.88 (which endorses ANSI N45.2.9) and Branch Technical Position (BTP) CMEB 9.5-1 (which references various National Fire Protection Association (NFPA) standards). Your ten exception requests deal with deviations to portions of NFPA Standards such as NFPA Standard Nos.10, 12A, 72D, and 72E, as well as to portions of ANSI N45.29.

We have reviewed these exception requests and have discussed our concerns with Mr. Mike Holmes and other members of your staff during a July 8,1986 telecon.

Our concerns, as addressed in this telecon, are documented in Enclosure 1 as a Request for Additional Information. Please provide this infomation within 45 days from the date of this letter. If you have any questions, please contact meat (301)492-7930 or Ken Heitner at (301) 492-8288.

l l

gWOO468 860814

, p ADOCK 05000267 * !

PDR '

l

T t

1- ,

, -)

The information in this letter affects fewer than 10 respondents; therefore, OMB Clearance is not required under P.L.96-511.  ;

Sincerely, hjo k h Charles S. Hinson, Project Mancger  !

l Standardization and Special Projects Directorate  :

Division of PWR Licensing-B l Office of Nuclear Reactor Regulation l

Enclosure:

i As stated '

! cc w/ enclosure: I j See next page l I

l I

I i

Y f

--- , . . - - . - - - - . . . ~ ,

m j Mr. R. O. Williams Public Service Company of Colorado Fort St. Vrain cc:

Mr. D. W. Warembourg, Manager Albert J. Hazle, Director Nuclear Engineering Division Radiation Control Division Public Service Company Department of Health of Colorado 4210 East lith Avenue P. O. Box 840 Denver, Colorado 80220 Denver, Colorado 80201 Mr. David Alberstein,14/159A Mr. J. W. Gahm, Manager GA Technologies, Inc. Nuclear Production Division Post Office Box 85608 Public Service Company of Colorado San Diego, California 92138 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Fuel Division Mr. L. W. Singleton, Manager Public Service Company of Colorado Quality Assurance Division P. O. Box 840 Fort St. Vrain Nuclear Station Denver, Colorado 80201 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Senior Resident Inspector U.S. Nuclear Regulatory Commission P. 0. Box 640 Platteville, Colcrado 80651 Xelley, Stansfield & 0'Donnell Public Service Company Building Room 900 550 15th Street Denver, Colorado 80202 Regional Administrator, Region IV U.S. Nuclear Regulatory Comission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 1

Chairman, Board of County Commissioners '

of Weld County, Colorado Greeley, Colorado 80631 )

t Regional Representative Radiation Programs i Environmental Protection Agency i 1800 Lincoln Street '

Denver, Colorado 80203 l

1 1

l

.- l s- -

i Enclosure 1

)

l REQUEST FOR ADDITIONAL INFORMATION FORT ST. VRAIN i

PROPOSED RECORD STORAGE CENTER l

l

1. The halon fire suppression system should be designed and installed in accordance with the guidelines of National Fire Protection Association (NFPA) Standard No. 12A (referenced in BTP CMEB 9.5-1). We would expect that the design concentration of halon gas would be 10 percent, maintained for 10 minutes duration. The system should have a 100 percent reserve supply of halon gas. A discharge test, featuring multiple test points and various levels, should be conducted prior to acceptance.
2. The fire detection / fire alarm system should be designed in accordance with the requirements of NFPA Standard Nos. 72D and 72E (referenced in BTPCMEB9.5-1). Design details pertaining to the location and spacing of fire smoke detectors, circuit supervision and local / remote alann annunication should be provided.
3. Portable fire extinguishers should be provided in accordance with NFPA Standard No. 10 (referenced in BTP CMEB 9.5-1).
4. The openings in the exterior walls should be protected by fire dampers or fire doors having a fire resistance rating comparable to the 2-hour fire rating of the walls.
5. The plant is designed to be capable of safe shutdown following a

" maximum" tornado with a 300 mph total horizontal wind velocity.

Demonstrate that any missiles resulting from the failure of the Record Storage Center will not damage any Category I structure or safety related equipment.

s i

yo-z s 7 August 14, 1986 The information in this letter affects fewer than 10 respondents; therefore, OMB Clearance is not required under P.L.96-511.

Sincerely, Original signed by Charles S. Hinson, Project Manager Standardization and Special Projects Directorate Division of PWR Licensing-B Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBUTION:

a DecRet-- F18e :

~

1

'NRC PDR ~ ~~'~'

Local PDR SSPD Reading FMiraglia 0GC-Bethesda EJordan <

BGrimes JPartlow DKubicki RLipinski PKuo JWermiel KHeitner CHinson PNoonan ACRS (10)

HThompson P,3S ' PBSS P P PBEB n PBS[o cw chi KHeitner 06ynch JWermiel PKuo

/D /86 08//z/86 08/13/86 08/ ('J/86 08//4/86- 08/,,

f 86 PE H@5e%o(Y) r w 08/p/86 1