ML20055G592

From kanterella
Jump to navigation Jump to search
Agrees W/Removal of B Helium Circulator,Per Requesting NRC Concurrence.Solution to Correct Leakage Problem by Removal of Circulator Acceptable
ML20055G592
Person / Time
Site: Fort Saint Vrain 
Issue date: 07/19/1990
From: Weiss S
Office of Nuclear Reactor Regulation
To: Crawford A
PUBLIC SERVICE CO. OF COLORADO
References
NUDOCS 9007230354
Download: ML20055G592 (3)


Text

g i

t

[ p quoq'o, oc UNITE D STATE s 9 (,g NUCLEAR REGUL ATORY COMMISSION P

g e

a wAssiNo ton. o. c. rosss o

4.....**'

Ouly 19,1990 Docket H0. 50-267 Mr. A. Clegg Crawford Vice President, Nuclear Operations Public Service Company of Colorado Post Office Bcx 840 Denver, Colorado 80201-0840

Dear Mr. Crawford:

t

SUBJECT:

"B". HELIUM CIRCULATOR REMOVAL By letter dated July 2,1990, you requested our concurrence with your plans to remove the "B" helium circulator from the reactor vessel and store it on-site until the NRC acts on your request for a possession only license for Fort St. Vrain (FSV).

We have reviewed your proposal and agree that (1) the B" helium circulator would have to be remved in order to ccrrect the seal leakage problem anyway; (2) the circulator is not needed for the present FSV shutdown conditions; i

and (3) your solution to correct the leakage problem by removt.1 of the circulator is acceptable.

7 Sincerely, i

fi Seymour H. Weiss, Director Non-Power Reactor, Deconnissioning and Environmental Project Directorate Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation cc: See next page t

DT

\\

\\ 5 9007230354 900719 l

PDR ADOCK 05000267

'P PDC L

t e,'

  • Pr. A. Clegg Crawford Dcclet No. 50-267 Public Service Conpany of Colorado Fort St. Vrain CC:

Mr. D. W. Warembourg, Manager Regional Represen'ative Nuclear Engineering Division Pediation Programs Public Service Company invironmental Protection Agency of Coloracc 1 Denver P16ce P. O. Box 840 99918th Street Suite 1300 Denver, Colorado 80201 0840 Denver, Colorado 80202-2413 Mr. David Alberstein, Manager RoLert M. Quiller Director Fort St. Vrain Services Radiation Control Division GA International Services Corporation Department of Health P. O. Box SE608 4210 fer,t lith Avenue I

San Dieco, California 92138 Denver, Colorado 80220 Mr. P. L. Brey, Manager Mr. Charles H. Fuller Nur'iear Licensing and Resource Nuclear Production and

?:enagement Division Station Kanogtr Public Service Company of Colorado Public Service Company of Colorido P. O. Box 840 16805 Weld County Road 19-1/2 Denver, Colorado 80201-0840 Platteville, Colorado 80651 Senior Resident Inspector Mr. P. F. Tomlinson, Hanager U.S. Nuclear Regulatory Commission Quality Assurance Division P. O. Box 640 Public Service Company of Colorado Platteville, Colorado 8055) 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Kelley, Standfield & 0'Donnell ATTN: Mr. J. K. Tarpey Mr. D.-D. Hock Public Service Company Butiding President and Chief Executive Officer Room 900 Public Service Company of Colorado 550 15th Street P. O. Cox 840 l

Denver, Colorado 80202 Denver, Colorado 80201-0840 Regional Administrator, Region IV Comitment Control Program U.S. Nuclear Regulatory Comission Coordinator 611 Pyan Plaza Drive, Suite 1000 Public Service Company of Colorado Arlington, Texas 76011 2420 W. 26th Avenue, Suite 100-0 Chairman, Board of County Comissioners of Weld County, Colorado Greeley, Colorado 80631 l

p I

July 19,1990 i

e DISTRIBUTION eDechetJ Her NRC & Local PDRs DCrutchfield WTravers EHylton PErickson 000 EJordan ACRS(10)

PDNP Reading Region IV, DRP Docket NO. 50-267 Hr. A. Clegg Crawford Vice President, Nuclear Operations Public Service Company of Colorado l

Post Office Box 840 Denver, Colorado 80201-0840 bear tir. Crawford, h

SUBJECT:

"D" HELIUM CIRCULATOR REMOVAL By letter dated July 2,1990, you requested our concurrence with your plans to remove the "B" helium circulator from the reactor vessel and store it on. site until the NRC acts on your request for a possession-only license for Fort St. Vrain (FSV).

We have reviewed your proposal and agree that (1) the B" helium circulator I

would have to be removed in order to correct the seal leakage problem anyway; (2)thecirculatorisnotceededforthepresentFSVscutdownconditions; and (3) your solution to correct the leakage problem by 6 9moval of the circulator is acceptable.

Sincerely,

/S/

Seymour H. Weiss, Director Non. Power Reactor, Decommissioning and Environmental Project Directorate Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation honJAr 06C/cs sne, ff/i o

0FC -:PDNP:L

PDNP:
PDNP:

f, 3 :

W.:............:............:............:.........

.:...... c-.

NAME:E}kion

PEric on
SWeis i

..y.....:............:............:............:.........

PfcfJ/D:p\\p@O: 7 /9/Q()

DATE :

OFFICIAL RECORD COPY Document Name: DOCKET 50-267 CRAWFORD, WEISS DFol

^ 1 'Q

\\

g

-