ML20136G120

From kanterella
Jump to navigation Jump to search
Forwards Annual Radioactive Effluent Release Rept for Jan- Dec 1996 & Jan-Mar 1997. All Effluent Releases Completed as of 960703.Repts on Activities After 960703 Reflect Disposal of Solid Waste
ML20136G120
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 03/11/1997
From: Borst F
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20136G123 List:
References
P-97013, NUDOCS 9703170208
Download: ML20136G120 (4)


Text

s s

s h Public Service'

=**W,*L.e Fort St. Vrain Nuclear Station 16805 WCR 19-1/2, Platteville, Colorado 80651 j

J March 11, 1997 Fort St. Vrain Unit No. 1 P-97013

.U.S.

Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 Docket No. 50-267

SUBJECT:

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Gentlemen:

Attached please find the Annual Radioactive Effluent Release Report for the Fort St. Vrain Nuclear Station.

This report covers the period January 1, 1996, through December 31, i

1996, as well as the period January 1, 1997, through March 31, 1997, and is submitted pursuant to Section 5.5.2 of the Fort St.

Vrain Decommissioning Technical Specifications (DTS).

All effluent releases were complete as of July 3, 1996.

Reports on activities after that date reflect disposal of solid waste from the site and from processors.

This report also includes results of the analysis of water collected from the Reactor Building Sump on December 9,

1996, following completion of all liquid radioactive effluent releases.

The results demonstrate that the Environmental Lower Limits of Detection (LLD) were met (copy attached).

As all liquid and gaseous radioactive waste releases and solid radioactive waste shipments from the Fort St. Vrain Nuclear Station j

have now been completed, this report represents the final Annual Radioactive Effluent Release Report for Docket No. 50-267.

If any additional information is identified, this final report will be supplemented at that time.

f bfLh I

9703170208 970311 PDR ADOCK 05000267 R

PDR

-.vvv,

4 P-97013 March 11, 1997 Page 2 Please contact Mr.

M.

H.

Holmes at (303) 571-7633 if you have questions regarding this report.

Sincerely, Uttbbb6L,A-7 gjSM -

Frederick'gJ. Borst Decommissioning Program Director FJB/tb Attachments 1

cc:

w/ attachments Regional Administrator, Region IV Mr. Robert Quillin, Director Radiation Control Division Colorado Department of Public Health and Environment RCD-DO-B1 4300 Cherry Creek Drive South Denver, CO 80222-1530 Mr. Milt Lammering, Chief Regional Representative, Radiation Program U.S.

Environmental Protection Agency Region VIII 999 18th Street, Suite 500 Denver, CO 80202-2405 Dr. James E. Johnson Department of Radiological Health Sciences MRB Building Colorado State University Fort Collins, CO 80523

P-97013 March 11, 1997 j

Page 3 l

cc:

w/ attachments (continued)

Ms. Pat Nelson Water Quality Control Division Colorado Department of Public Health & Environment Permits & Enforcement Section

]

WQCD-PD-B2 4300 Cherry Creek Drive South Denver, Colorado 80222-1530 Mr. Jan Hagers U.S.

Departmant of Energy Idalic Operations Of fice 785 DOE Place Mail Stop 1145 Idaho Falls, ID 83401 l

(

4

)

4 f

a

O Results of Sump Water Sample Analysis Nuclide Concentration (pCi/L)

MDC' 11-3

< 370 370 Cs-134

<l.4 1.4 l

Cs.137 4.6 (2.1)6 0

Zr-95

<3.0 3.0 Nb-95

< l.3 1.3 Co-58

< l.4 1.4 Mn-54

< l.4 1.4 Zn-65

<3.6 3.6 Fe-59 4.2 (4.9) 4.0 Co-60

< l.4 1.4 Ba-140

< 2.2 2.2 La-140

< 2.5 2.5

  • Minimum Detectable ConcentntL:.

b l.96S due Only to Counting Statistics, i.e., the 95% confidence interval.

i