IR 05000327/1987008

From kanterella
Jump to navigation Jump to search
Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Repts 50-327/87-08 & 50-328/87-08.Violation Re Maint of Condensate Demineralizer Waste Evaporator Sys Discussed
ML20236B504
Person / Time
Site: Sequoyah  
Issue date: 07/22/1987
From: Zech G
NRC OFFICE OF SPECIAL PROJECTS
To: White S
TENNESSEE VALLEY AUTHORITY
References
NUDOCS 8707290131
Download: ML20236B504 (2)


Text

r; i,

g

.

'-

~

JUL 2 219BT I

Ignnessee Valley Authority j

. \\ ATTN:

Mr. S.;A. White

.

Manager of Nuclear. Power 6N 38A Lookout Place 1101 Market Street

.

Chattanooga, TN 37402-2801 Gentlemen:

SUBJECT:

REPORT NOS. 50-327/87-08 AND 50-328/87-08 Thank you for your response of May 15, 1987, to our Notices of Violation and Deviation, issued on April 10, 1987, concerning activities conducted at your Sequoyah facility.

We have evaluated your response and found that it meets the requirements of 10 CFR 2.201.

We will examine the implementation of your

,

corrective actions during future inspections, j

Although, you did not deny Deviation 327,328/87-08-01 in your response, you'

did provide new information concerning the routine preventive maintenance of the Condensate Demineralized Waste Evaporator (CDWE) system, as well as indicating that a section in the body of the NRC inspection report itself was

'

not accurate.

The statement referred to was that a proposed FSAR change would i

" eliminate the requirement for preventi.ve maintenance in this section of the FSAR".

The intent of this statement was to reference the requirement in the -

'

FSAR to manuals" perform preventive maintenance " described in manufacturer's instruction This requirement was eliminated in Revision 4 of the FSAR and was

.

replaced with the statement," preventive maintenance is performed on equiament

,

as determined to be required by the plant maintenance organization.

T1e

determination will be based on experience, consideration of the equipment's importance to safe operation of the plant, and history of equipment failure."

In response, we simply point out that you have subsequently determined that the equipment is not important to the safe operation of the unit, tracking and trending of raw maintenance data (work requests) has not been actively pursued for the CDWE system, and there is no objective evidence available that indi-cates industry experience was used in the initial development or maintenance of procedures and administrative controls for the CDWE system.

We appreciate your cooperation in this matter.

Sincerely, OHIGINAL SIGNED BY GARY G. ZECH g

Gary G. Zech, Assistant Director Inspection Programs Division of TVA Projects Office of Special Projects cc:

(See page 2)

8707290131 870722 ADOCK0500g7 PDR Ib a

f.goi

%

JUL 2 21ga7 Tennessee Valley Authority

LHIL.Abercrombie,SiteDirector cc:

Sequoyah Nuclear Plant Lk A. Kirkebo, Director, Nuclear Engineering LRf L. Gridley, Director Nuclear Safety and Licensing J.R. Harding,SiteLicensing Manager bcc:( # G. Keppler, OSP (Sf D. Ebneter, OSP t # A. Zwolinski, OSP LBf D. Liaw, OSP v5f D. Richardson, OSP vS'. R. Connelly, 01A K. P. Barr, OSP/RII kNRC Resident Inspector NRC Document Control Desk State of Tennessee

,

7/27./87 7/2/87

,./gi/87

,

______ _________